Automated measurement of fetal head circumference using 2D ultrasound images
Open accessAbstract
In this paper we present a computer aided detection (CAD) system for automated measurement of the fetal head circumference (HC) in 2D ultrasound images for all trimesters of the pregnancy. The HC can be used to estimate the gestational age and monitor growth of the fetus. Automated HC assessment could be valuable in developing countries, where there is a severe shortage of trained sonographers. The CAD system consists of two steps: First, Haar-like features were computed from the ultrasound images to train a random forest classifier to locate the fetal skull. Secondly, the HC was extracted using Hough transform, dynamic programming and an ellipse fit. The CAD system was trained on 999 images and validated on an independent test set of 335 images from all trimesters. The test set was manually annotated by an experienced sonographer and a medical researcher. The reference gestational age (GA) was estimated using the crown-rump length measurement (CRL). The mean difference between the reference GA and the GA estimated by the experienced sonographer was 0.8 ± 2.6, -0.0 ± 4.6 and 1.9 ± 11.0 days for the first, second and third trimester, respectively. The mean difference between the reference GA and the GA estimated by the medical researcher was 1.6 ± 2.7, 2.0 ± 4.8 and 3.9 ± 13.7 days. The mean difference between the reference GA and the GA estimated by the CAD system was 0.6 ± 4.3, 0.4 ± 4.7 and 2.5 ± 12.4 days. The results show that the CAD system performs comparable to an experienced sonographer. The presented system shows similar or superior results compared to systems published in literature. This is the first automated system for HC assessment evaluated on a large test set which contained data of all trimesters of the pregnancy.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Five studies used the freely available 'HC18' data set for training and testing algorithms, which contained 1334 2D images from 551 women of the standard fetal head plane.
“Five studies used the freely available ‘HC18’ data set [45] for training and testing the algorithms, which contained 1334 2D images from 551 women of the standard fetal head plane [18,34,37,38,40].”
From Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology (2023) · cites this paper as [45]
The Materials and methods > Data section reports 1,334 2D fetal-head ultrasound images from 551 pregnant women, and the Discussion > Study limitations section indicates that obtaining the 2D standard plane was required. Our copy does not identify the dataset as ‘HC18’ or establish that it was freely available. The five studies are cited separately in the citing sentence, so their use of the dataset is not attributed to this source. (LLM, conf=0.84)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538 · see citing works
Robust Real-Time Face Detection
Viola, P., & Jones, M. J. (2004) · International Journal of Computer Vision · doi:10.1023/b:visi.0000013087.49260.fb · Cited by 14,097 · see citing works
Comparing images using the Hausdorff distance
Huttenlocher, D. P., Klanderman, G. A., & Rucklidge, W. J. (1993) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.232073 · Cited by 4,545 · see citing works
An extended set of Haar-like features for rapid object detection
Lienhart, R., & Maydt, J. (2003) · Proceedings. International Conference on Image Processing · doi:10.1109/icip.2002.1038171 · Cited by 2,977 · cited 1× · see citing works
“Feature extraction: Haar-like features [18] were used to be able to discriminate between background pixels and pixels that belong to the fetal skull.”
MethodDirect Least Square Fitting of Ellipses
Fitzgibbon, A., Pilu, M., & Fisher, R. B. (1999) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.765658 · Cited by 2,797 · see citing works
Sørensen, T. B., Sorensen, T., Biering-Sørensen, T., Ti, S., & Sorensen, J. (1948) · Medical Entomology and Zoology · Cited by 2,038 · see citing works
On the theory of dynamic programming
Bellman, R. (1952) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.38.8.716 · Cited by 998 · see citing works
Suzuki, E., Mathers, C. D., Moller, A., Alkema, L., Say, L., Gemmill, A., Mills, S. L., Chou, D., & Hogan, D. R. (2014) · Cited by 680 · see citing works
Verburg, B. O., Steegers, E. A. P., de Ridder, M. A. J., Snijders, R. J. M., Smith, E. A., Albert Hofman, D., Moll, H. A., Jaddoe, V. W. V., & Witteman, J. C. M. (2008) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.5225 · Cited by 505 · see citing works
Carneiro, G., Georgescu, B., Good, S., & Comaniciu, D. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.928917 · Cited by 205 · see citing works
Rueda, S., Fathima, S., Knight, C. L., Yaqub, M. K., Papageorghiou, A. T., Rahmatullah, B., Foi, A., Maggioni, M., Pepe, A., Tohka, J., et al. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2276943 · Cited by 177 · see citing works
Lü, W., & Tan, J. (2007) · Pattern Recognition · doi:10.1016/j.patcog.2007.09.006 · Cited by 162 · see citing works
A review of training opportunities for ultrasonography in low and middle income countries
LaGrone, L. N., Sadasivam, V., Kushner, A. L., & Groen, R. S. (2012) · Tropical Medicine & International Health · doi:10.1111/j.1365-3156.2012.03014.x · Cited by 142 · see citing works
Namburete, A. I. L., Xie, W., Yaqub, M., Zisserman, A., & Noble, J. A. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.02.006 · Cited by 95 · see citing works
Sofka, M., Zhang, J., Good, S., Zhou, S. K., & Comaniciu, D. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2301936 · Cited by 40 · see citing works
Zhang, L., Ye, X., Lambrou, T., Duan, W., Allinson, N., & Dudley, N. J. (2016) · Physics in Medicine & Biology · doi:10.1088/0031-9155/61/3/1095 · Cited by 34 · see citing works
Carneiro, G., Amat, F., Georgescu, B., Good, S., & Comaniciu, D. (2008) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr.2008.4587358 · Cited by 32 · see citing works
Automated 3D Ultrasound Biometry Planes Extraction for First Trimester Fetal Assessment
Ryou, H., Yaqub, M. K., Cavallaro, A., Roseman, F., Papageorghiou, A. T., & Noble, J. A. (2016) · Lecture notes in computer science · doi:10.1007/978-3-319-47157-0_24 · Cited by 31 · see citing works
Difference of Gaussians revolved along elliptical paths for ultrasound fetal head segmentation
Foi, A., Maggioni, M., Pepe, A., Rueda, S., Noble, J. A., Papageorghiou, A. T., & Tohka, J. (2014) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2014.09.006 · Cited by 30 · see citing works
Pérez-González, J., Muñoz, J., Porras, M. C. R., Cosı́o, F. A., & Medina-Bañuelos, V. (2015) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-319-13117-7_85 · Cited by 29 · see citing works
Automated Telehealth System for Fetal Growth Detection and Approximation of Ultrasound Images
Jatmiko, W., Habibie, I., Ma’Sum, M. A., Rahmatullah, R., & Satwika, I. P. (2015) · International Journal on Smart Sensing and Intelligent Systems · doi:10.21307/ijssis-2017-779 · Cited by 27 · see citing works
Fetal biometry: a comparison between experienced sonographers and automated measurements
Žalud, I., Good, S., Carneiro, G., Georgescu, B., Aoki, K., Green, L., Shahrestani, F., & Okumura, R. (2009) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/14767050802415736 · Cited by 23 · see citing works
Ni, D., Yang, Y., Li, S., Qin, J., Ouyang, S., Wang, T., & Heng, P. (2013) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2013.6556589 · Cited by 23 · see citing works
Where is my baby? A fast fetal head auto-alignment in 3D-ultrasound
Cuingnet, R., Somphone, O., Mory, B., Prevost, R., Yaqub, M. K., Napolitano, R., Papageorghiou, A. T., Roundhill, D. N., Noble, J. A., & Ardon, R. (2013) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2013.6556588 · Cited by 19 · see citing works
Anto, E. A., Amoah, B., & Crimi, A. (2015) · doi:10.1109/embc.2015.7318481 · Cited by 15 · see citing works
Plane Localization in 3-D Fetal Neurosonography for Longitudinal Analysis of the Developing Brain
Yaqub, M. K., Rueda, S., Kopuri, A., Melo, P., Papageorghiou, A. T., Sullivan, P. B., McCormick, K., & Noble, J. A. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2435651 · Cited by 14 · see citing works
Satwika, I. P., Habibie, I., Ma’Sum, M. A., Febrian, A., & Budianto, E. (2014) · International Conference on Advanced Computer Science and Information Systems · doi:10.1109/icacsis.2014.7065898 · Cited by 13 · see citing works
Flagged first, then by citations
Research works printed but not linked: 4
- [10]Ponomarev GV, Gelfand MS, Kazanov MD. A multilevel thresholding combined with edge detection and shape-based recognition for segmentation of fetal ultrasound images. Proceedings of Challenge US: Biometric Measurements from Fetal Ultrasound Images, ISBI. 2012; p. 17–19.
- [11]Sun C. Automatic fetal head measurements from ultrasound images using circular shortest paths. Proceedings of Challenge US: Biometric Measurements from Fetal Ultrasound Images, ISBI. 2012; p. 13–15.
- [12]Stebbing RV, McManigle JE. A boundary fragment model for head segmentation in fetal ultrasound. Proceedings of Challenge US: Biometric Measurements from Fetal Ultrasound Images, ISBI. 2012; p. 9–11.
- [13]Ciurte A, Bresson X, Cuadra MB. A semi-supervised patch-based approach for segmentation of fetal ultrasound imaging. Proceedings of Challenge US: Biometric Measurements from Fetal Ultrasound Images, ISBI. 2012; p. 5–7.
Cited by
Sorted by citations
Zeng, Y., Tsui, P.-H., Wu, W., Zhou, Z., & Wu, S. (2021) · Journal of Digital Imaging · doi:10.1007/s10278-020-00410-5 · Cited by 113 · see citing works
Use of artificial intelligence in obstetrics: Not quite ready for prime time
Sarno, L., Neola, D., Carbone, L., Saccone, G., Carlea, A., Miceli, M., Iorio, G. G., Mappa, I., Rizzo, G., Girolamo, R. D., et al. (2023) · American Journal of Obstetrics & Gynecology MFM · doi:10.1016/j.ajogmf.2022.100792 · Cited by 47 · see citing works
Li, P., Zhao, H., Liu, P., & Cao, F. (2020) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-020-02242-5 · Cited by 47 · see citing works
Jost, E., Kosian, P., Jimenez Cruz, J., Albarqouni, S., Gembruch, U., Strizek, B., & Recker, F. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12216833 · Cited by 44 · see citing works
“Five studies used the freely available ‘HC18’ data set [45] for training and testing the algorithms, which contained 1334 2D images from 551 women of the standard fetal head plane [18,34,37,38,40].”
MethodImproving Fetal Head Contour Detection by Object Localisation with Deep Learning
Al-Bander, B., Alzahrani, T., Alzahrani, S., Williams, B. M., & Zheng, Y. (2020) · Communications in Computer and Information Science · doi:10.1007/978-3-030-39343-4_12 · Cited by 44 · see citing works
Exploring a new paradigm for the fetal anomaly ultrasound scan: Artificial intelligence in real time
Matthew, J., Skelton, E., Day, T. G., Zimmer, V. A., Gomez, A., Wheeler, G., Toussaint, N., Liu, T., Budd, S., Lloyd, K., et al. (2022) · Prenatal Diagnosis · doi:10.1002/pd.6059 · Cited by 41 · see citing works
Arroyo, J., Marini, T. J., Saavedra, A. C., Toscano, M., Baran, T. M., Drennan, K., Dozier, A., Zhao, Y. T., Egoavil, M., Tamayo, L., et al. (2022) · PLOS ONE · doi:10.1371/journal.pone.0262107 · Cited by 40 · see citing works
Model-Agnostic Method for Thoracic Wall Segmentation in Fetal Ultrasound Videos
Shozu, K., Komatsu, M., Sakai, A., Komatsu, R., Dozen, A., Machino, H., Yasutomi, S., Arakaki, T., Asada, K., Kaneko, S., et al. (2020) · Biomolecules · doi:10.3390/biom10121691 · Cited by 38 · see citing works
Alzubaidi, M., Agus, M., Shah, U., Makhlouf, M., Alyafei, K., & Househ, M. (2022) · Diagnostics · doi:10.3390/diagnostics12092229 · Cited by 35 · see citing works
Agent with Warm Start and Adaptive Dynamic Termination for Plane Localization in 3D Ultrasound
Yang, X., Dou, H., Huang, R., Xue, W., Huang, Y., Qian, J., Zhang, Y., Luo, H., Guo, H., Wang, T., et al. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3069663 · Cited by 32 · see citing works
Zeng, W., Luo, J., Cheng, J., & Lu, Y. (2022) · Medical Physics · doi:10.1002/mp.15700 · Cited by 31 · see citing works
Zhang, J., Petitjean, C., & Ainouz, S. (2022) · Journal of Imaging · doi:10.3390/jimaging8020023 · Cited by 21 · see citing works
Yang, C., Yang, Z., Liao, S., Guo, J., Yin, S., Liu, C., & Kang, Y. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.105801 · Cited by 16 · see citing works
ConfIC-RCA: Statistically Grounded Efficient Estimation of Segmentation Quality
Cosarinsky, M., Billot, R., Mansilla, L., Jimenez, G., Gaggión, N., Fu, G., Tirer, T., & Ferrante, E. (2025) · arXiv
“2 including SCD [44], HC18 [45], PSFHS [46], PH2 [47], ISIC 2018 [48], NuCLS [49], JSRT [50], 3D-IRCAdB [51], WBC-CV and WBC-JTSC [52].”
- Authors
- van den Heuvel, T. L. A., de Bruijn, D., de Korte, C. L., & Ginneken, B. V.
- Affiliations
- Radboud University Medical Center (NL)
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2018-08-23
- Volume
- 13
- Issue
- 8
- Pages
- e0200412
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC6107118
- OpenAlex
- W2888303187
- Cited by
- 280
- References
- 27
- Citations by year
- 2026: 52 · 2025: 47 · 2024: 39 · 2023: 31 · 2022: 44 · 2021: 25 · 2020: 32 · 2019: 9 · 2018: 1
- FWCI
- 8.38
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft) (submittedVersion, other-oa)
- Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
- Radboud Repository (Radboud University) (submittedVersion)
- Radboud Repository (Radboud University) (submittedVersion, other-oa)
- Funders
- Life Sciences & Health for Development (LSH14ET04)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Prenatal Screening and Diagnostics
- Keywords
- fetal head circumference, computer-aided detection, two-dimensional ultrasound, gestational age estimation, Haar-like features, random forest, Hough transform, ellipse fitting, crown-rump length, fetal growth monitoring
- MeSH terms
- Automation, Female, Fetus, Gestational Age, Head, Humans, Pregnancy, Ultrasonography, Prenatal, Fetal Development
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review