The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Electromagnetic Tracking in Medicine—A Review of Technology, Validation, and Applications
Abstract
Object tracking is a key enabling technology in the context of computer-assisted medical interventions. Allowing the continuous localization of medical instruments and patient anatomy, it is a prerequisite for providing instrument guidance to subsurface anatomical structures. The only widely used technique that enables real-time tracking of small objects without line-of-sight restrictions is electromagnetic (EM) tracking. While EM tracking has been the subject of many research efforts, clinical applications have been slow to emerge. The aim of this review paper is therefore to provide insight into the future potential and limitations of EM tracking for medical use. We describe the basic working principles of EM tracking systems, list the main sources of error, and summarize the published studies on tracking accuracy, precision and robustness along with the corresponding validation protocols proposed. State-of-the-art approaches to error compensation are also reviewed in depth. Finally, an overview of the clinical applications addressed with EM tracking is given. Throughout the paper, we report not only on scientific progress, but also provide a review on commercial systems. Given the continuous debate on the applicability of EM tracking in medicine, this paper provides a timely overview of the state-of-the-art in the field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Publication bias in clinical research
Easterbrook, P. J., Gopalan, R., Berlin, J. A., & Matthews, D. R. (1991) · The Lancet · doi:10.1016/0140-6736(91)90201-y · Cited by 3,109 · cited 1×
“Possibly, problematic applications already fail in a phantom state and/or are not published due to publication bias [28].”
BackgroundMagnetic Position and Orientation Tracking System
Raab, F., Blood, E., Steiner, T., & Jones, H. (1979) · IEEE Transactions on Aerospace and Electronic Systems · doi:10.1109/taes.1979.308860 · Cited by 614
Robotic Magnetic Navigation for Atrial Fibrillation Ablation
Pappone, C., Vicedomini, G., Manguso, F., Gugliotta, F., Mazzone, P., Gulletta, S., Sora, N., Sala, S., Marzi, A., Augello, G., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.11.058 · Cited by 402
Milne, A. D., Chess, D. G., Johnson, J. A., & King, G. J. W. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(96)83335-5 · Cited by 299
Accuracy assessment and interpretation for optical tracking systems
Wiles, A. D., Thompson, D. G., & Frantz, D. D. (2004) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.536128 · Cited by 283
Accurate localization of RFID tags using phase difference
Hekimian-Williams, C., Grant, B., Liu, X., Zhang, Z., & Kumar, P. (2010) · 2010 IEEE International Conference on RFID (IEEE RFID 2010) · doi:10.1109/rfid.2010.5467268 · Cited by 251
Fried, M. P., Kleefield, J., Gopal, H., Reardon, E., Ho, B. T., & Kuhn, F. A. (1997) · The Laryngoscope · doi:10.1097/00005537-199705000-00008 · Cited by 239
Wood, B. J., Zhang, H., Durrani, A., Glossop, N., Ranjan, S., Lindisch, D., Levy, E., Banovac, F., Borgert, J., Krueger, S., et al. (2005) · Journal of Vascular and Interventional Radiology · doi:10.1097/01.rvi.0000148827.62296.b4 · Cited by 227
Self-citationAdvanced superconducting gradiometer/Magnetometer arrays and a novel signal processing technique
Wynn, W., Frahm, C., Carroll, P., Clark, R., Wellhoner, J., & Wynn, M. (1975) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1975.1058672 · Cited by 205
Computer-aided navigation in neurosurgery
Grunert, P., Darabi, K., Espinosa, J., & Filippi, R. (2003) · Neurosurgical Review · doi:10.1007/s10143-003-0262-0 · Cited by 192
Three-Dimensional Tissue Deformation Recovery and Tracking
Mountney, P., Stoyanov, D., & Yang, G.-Z. (2010) · IEEE Signal Processing Magazine · doi:10.1109/msp.2010.936728 · Cited by 188
Accuracy assessment protocols for electromagnetic tracking systems
Frantz, D. D., Wiles, A. D., Leis, S. E., & Kirsch, S. R. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/14/314 · Cited by 173
Ren, H., & Kazanzides, P. (2012) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2010.2095504 · Cited by 164
Design and application of an assessment protocol for electromagnetic tracking systems
Hummel, J. B., Bax, M. R., Figl, M., Kang, Y., Maurer, C. R., Birkfellner, W., Bergmann, H., & Shahidi, R. (2005) · Medical Physics · doi:10.1118/1.1944327 · Cited by 155
Self-citationComputer-aided navigation in neurosurgery
Hellwig, D. (2003) · Neurosurgical Review · doi:10.1007/s10143-003-0264-y · Cited by 144
The Effects of Metals and Interfering Fields on Electromagnetic Trackers
Nixon, M. A., McCallum, B. C., Fright, W. R., & Price, N. B. (1998) · PRESENCE Virtual and Augmented Reality · doi:10.1162/105474698565587 · Cited by 122
Venkatesan, A. M., Kadoury, S., Abi‐Jaoudeh, N., Levy, E. B., Maass‐Moreno, R., Krücker, J. F., Dalal, S., Xu, S., Glossop, N., & Wood, B. J. (2011) · Radiology · doi:10.1148/radiol.11101985 · Cited by 118
Technical accuracy of optical and the electromagnetic tracking systems
Koivukangas, T., Katisko, J., & Koivukangas, J. P. (2013) · SpringerPlus · doi:10.1186/2193-1801-2-90 · Cited by 102
Calibration of position and angular data from a magnetic tracking device
Day, J. S., Murdoch, D. J., & Dumas, G. A. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00044-0 · Cited by 100
Electromagnetic navigation bronchoscopy: A descriptive analysis.
Leong, S. C., Ju, H. S., Marshall, H., Bowman, R., Yang, I. A., Ree, A.-M., Saxon, C., & Fong, K. M. (2012) · PubMed Central · doi:10.3978/j.issn.2072-1439.2012.03.08 · Cited by 96
Evaluation of a new electromagnetic tracking system using a standardized assessment protocol
Hummel, J. B., Figl, M., Birkfellner, W., Bax, M. R., Shahidi, R., Maurer, C. R., & Bergmann, H. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/10/n01 · Cited by 95
Self-citationSandler, H. M., Liu, P., Dunn, R. L., Khan, D. C., Tropper, S., Sanda, M. G., & Mantz, C. A. (2010) · Urology · doi:10.1016/j.urology.2009.10.072 · Cited by 73
Measurement and calibration of static distortion of position data from 3D trackers
Bryson, S. (1992) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.60417 · Cited by 64
Model for defining and reporting reference-based validation protocols in medical image processing
Jannin, P., Grova, C., & Maurer, C. R. (2006) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-006-0044-6 · Cited by 64
Hybrid bronchoscope tracking using a magnetic tracking sensor and image registration
Mori, K., Deguchi, D., Akiyama, K., Kitasaka, T., Suenaga, Y., Maurer, C. R., Takabatake, H., Mori, M., & Natori, H. (2005) · Lecture notes in computer science · Cited by 62
Hybrid Bronchoscope Tracking Using a Magnetic Tracking Sensor and Image Registration
Mori, K., Deguchi, D., Akiyama, K., Kitasaka, T., Maurer, C. R., Suenaga, Y., Takabatake, H., Mori, M., & Natori, H. (2005) · Lecture notes in computer science · doi:10.1007/11566489_67 · Cited by 60
Electromagnetic-Tracked Biopsy under Ultrasound Guidance: Preliminary Results
Hakimé, A., Deschamps, F. J., de Carvalho, E. M., et al. (2011) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-011-0278-8 · Cited by 58
Effect of 3D ultrasound probes on the accuracy of electromagnetic tracking systems
Hastenteufel, M., Vetter, M., Meinzer, H.-P., & Ivo Wolf, A. (2006) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2006.05.013 · Cited by 55
Barratt, D. C., Davies, A. H., Hughes, A. D., Thom, S., & Humphries, K. N. (2001) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00395-7 · Cited by 55
Meyer, B., Peter, O., Nagel, M., Hoheisel, M., Frericks, B. B., Wolf, K.-J., & Wacker, F. K. (2008) · European Radiology · doi:10.1007/s00330-008-1063-1 · Cited by 54
October, T. W., & Hardart, G. E. (2009) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0b013e31819a3668 · Cited by 44
Nasoenteral feeding tube placement by nurses using an electromagnetic guidance system (with )
Mathus-Vliegen, E. M. H., Duflou, A., Spanier, M., & Fockens, P. (2010) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2009.10.046 · Cited by 41
Accuracy considerations in image-guided cardiac interventions: experience and lessons learned
Linte, C. A., Lang, P., Rettmann, M. E., Cho, D. S., Holmes, D. R., Robb, R. A., & Peters, T. M. (2011) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-011-0621-1 · Cited by 22
Self-citationWu, X., & Taylor, R. H. (2003) · Lecture notes in computer science · doi:10.1007/978-3-540-39903-2_27 · Cited by 20
Preliminary experience with electromagnetic navigation system in TKA
Tigani, D. S., Busacca, M., Moio, A., Rimondi, E., Piccolo, N. D., & Sabbioni, G. (2008) · The Knee · doi:10.1016/j.knee.2008.09.004 · Cited by 20
Immersive 3DUI on one dollar a day
Basu, A., Saupe, C., Refour, E., Raij, A. B., & Johnsen, K. (2012) · IEEE Symposium on 3D User Interfaces (3DUI) · doi:10.1109/3dui.2012.6184191 · Cited by 18
Update on radiation-based therapies for prostate cancer
Kwok, Y., & Ellsworth, S. G. (2010) · Current Opinion in Oncology · doi:10.1097/cco.0b013e3283378c84 · Cited by 14
Feurer, R., Hennersperger, C., Runyan, J. B., Seifert, C. L., Pongratz, J., Wilhelm, M., Pelisek, J., Navab, N., Bartels, E., & Poppert, H. (2012) · Journal of Biomedical Graphics and Computing · doi:10.5430/jbgc.v2n2p1 · Cited by 8
Lațcu, D. G., Bun, S., Ricard, P., & Saoudi, N. C. (2011) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2011.03051.x · Cited by 5
Magnetische Navigation in der elektrophysiologischen Diagnostik und Therapie
Schimpf, R., Reents, T., Hessling, G., Deisenhofer, I., Pflaumer, A., Estner, H., Wu, J., Üçer, E., Zrenner, B., Sueselbeck, T., et al. (2007) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-007-0575-8 · Cited by 1
Cited by
Shape Sensing Techniques for Continuum Robots in Minimally Invasive Surgery: A Survey
Shi, C., Luo, X., Qi, P., Li, T., Song, S., Najdovski, Z., Fukuda, T., & Ren, H. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2622361 · Cited by 420
The status of augmented reality in laparoscopic surgery as of 2016
Bernhardt, S., Nicolau, S. A., Soler, L., & Doignon, C. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.01.007 · Cited by 314
Challenges of continuum robots in clinical context: a review
da Veiga, T., Chandler, J. H., Lloyd, P., Pittiglio, G., Wilkinson, N. J., Hoshiar, A. K., Harris, R. A., & Valdastri, P. (2020) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ab9f41 · Cited by 280
Alambeigi, F., Aghajani Pedram, S., Speyer, J. L., Rosen, J., Iordachita, I., Taylor, R. H., & Armand, M. (2020) · IEEE Transactions on Robotics · doi:10.1109/tro.2019.2946726 · Cited by 48
Metadata
- Authors
- Franz, A. M., Haidegger, T., Birkfellner, W., Cleary, K., Peters, T. M., & Maier-Hein, L.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2014-08
- Volume
- 33
- Issue
- 8
- Pages
- 1702-1725
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2013681472
- Cited by
- 504
- References
- 40
- FWCI
- 13.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.