A Novel Multiple-Instance Learning-Based Approach to Computer-Aided Detection of Tuberculosis on Chest X-Rays
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
To reach performance levels comparable to human experts, computer-aided detection (CAD) systems are typically optimized following a supervised learning approach that relies on large training databases comprising manually annotated lesions. However, manually outlining those lesions constitutes a difficult and time-consuming process that renders detailedly annotated data difficult to obtain. In this paper, we investigate an alternative approach, namely multiple-instance learning (MIL), that does not require detailed information for optimization. We have applied MIL to a CAD system for tuberculosis detection. Only the case condition (normal or abnormal) was required during training. Based upon the well-known miSVM technique, we propose an improved algorithm that overcomes miSVM's drawbacks related to positive instance underestimation and costly iteration. To show the advantages of our MIL-based approach as compared with a traditional supervised one, experiments with three X-ray databases were conducted. The area under the receiver operating characteristic curve was utilized as a performance measure. With the first database, for which training lesion annotations were available, our MIL-based method was comparable to the supervised system ( 0.86 versus 0.88 ). When evaluating the remaining databases, given their large difference with the previous image set, the most appealing strategy was to retrain the CAD systems. However, since only the case condition was available, only the MIL-based system could be retrained. This scenario, which is common in real-world applications, demonstrates the better adaptation capabilities of the proposed approach. After retraining, our MIL-based system significantly outperformed the supervised one ( 0.86 versus 0.79 and 0.91 versus 0.85 , and p=0.0002 , respectively).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cortes, C., & Vapnik, V. (1995) · Machine Learning · doi:10.1007/bf00994018 · Cited by 59,421
Multiresolution gray-scale and rotation invariant texture classification with local binary patterns
Ojala, T., Pietikainen, M., & Maenpaa, T. (2002) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2002.1017623 · Cited by 15,398
Solving the multiple instance problem with axis-parallel rectangles
Dietterich, T. G., Lathrop, R. H., & Lozano-Pérez, T. (1997) · Artificial Intelligence · doi:10.1016/s0004-3702(96)00034-3 · Cited by 2,866 · cited 2×
“In this paper, we investigate an alternative machine learning approach, known as multiple-instance learning (MIL) [16], that does not require labeling of each feature sample during training but only a global class label characterizing a group of samples.”
BackgroundMethodMuyoyeta, M., Maduskar, P., Moyo, M., Kasese, N., Milimo, D., Spooner, R., Kapata, N., Hogeweg, L., van Ginneken, B., & Ayles, H. (2014) · PLoS ONE · doi:10.1371/journal.pone.0093757 · Cited by 98
Self-citationMaduskar, P., Muyoyeta, M., Ayles, H., Hogeweg, L., Peters-Bax, L., & van Ginneken, B. (2013) · The International Journal of Tuberculosis and Lung Disease · doi:10.5588/ijtld.13.0325 · Cited by 77
Self-citation
Cited by
Multiple instance learning: A survey of problem characteristics and applications
Carbonneau, M.-A., Cheplygina, V., Granger, E., & Gagnon, G. (2018) · Pattern Recognition · doi:10.1016/j.patcog.2017.10.009 · Cited by 740
“Quantitative evaluation is performed in [58, 142, 144].”
BackgroundInfluentialAn Efficient Deep Learning Approach to Pneumonia Classification in Healthcare
Stephen, O., Sain, M., Maduh, U. J., & Jeong, D.-U. (2019) · Journal of Healthcare Engineering · doi:10.1155/2019/4180949 · Cited by 616
Deep image mining for diabetic retinopathy screening
Quellec, G., Charrière, K., Boudi, Y., Cochener, B., & Lamard, M. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.04.012 · Cited by 520
Learning to Read Chest X-Rays: Recurrent Neural Cascade Model for Automated Image Annotation
Shin, H.-C., Roberts, K., Lu, L., Demner-Fushman, D., Yao, J., & Summers, R. M. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.274 · Cited by 373
Machine learning approaches in medical image analysis: From detection to diagnosis
de Bruijne, M. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.06.032 · Cited by 347
Metadata
- Authors
- Melendez, J., van Ginneken, B., Maduskar, P., Philipsen, R. H. H. M., Reither, K., Breuninger, M., Adetifa, I. M. O., Maane, R., Ayles, H., & Sanchez, C. I.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2015-01
- Volume
- 34
- Issue
- 1
- Pages
- 179-192
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2015103117
- Cited by
- 130
- References
- 5
- FWCI
- 4.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Novel Multiple-Instance Learning-Based Approach to Computer-Aided Detection of Tuberculosis on Chest X-Rays. https://app.cochat.ai/papers/10.1109/tmi.2014.2350539
- The paper
- Melendez, J., van Ginneken, B., Maduskar, P., Philipsen, R. H. H. M., Reither, K., Breuninger, M., Adetifa, I. M. O., Maane, R., Ayles, H., & Sanchez, C. I. (2015). A Novel Multiple-Instance Learning-Based Approach to Computer-Aided Detection of Tuberculosis on Chest X-Rays. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2014.2350539
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.