CoChat

A Novel Multiple-Instance Learning-Based Approach to Computer-Aided Detection of Tuberculosis on Chest X-Rays

Melendez, Jaime, van Ginneken, Bram, Maduskar, Pragnya, Philipsen, Rick H. H. M., Reither, Klaus, Breuninger, Marianne, Adetifa, Ifedayo M. O., Maane, Rahmatulai, Ayles, Helen, Sanchez, Clara I. · 2015 · IEEE Transactions on Medical Imaging
Cited by 130

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

To reach performance levels comparable to human experts, computer-aided detection (CAD) systems are typically optimized following a supervised learning approach that relies on large training databases comprising manually annotated lesions. However, manually outlining those lesions constitutes a difficult and time-consuming process that renders detailedly annotated data difficult to obtain. In this paper, we investigate an alternative approach, namely multiple-instance learning (MIL), that does not require detailed information for optimization. We have applied MIL to a CAD system for tuberculosis detection. Only the case condition (normal or abnormal) was required during training. Based upon the well-known miSVM technique, we propose an improved algorithm that overcomes miSVM's drawbacks related to positive instance underestimation and costly iteration. To show the advantages of our MIL-based approach as compared with a traditional supervised one, experiments with three X-ray databases were conducted. The area under the receiver operating characteristic curve was utilized as a performance measure. With the first database, for which training lesion annotations were available, our MIL-based method was comparable to the supervised system ( 0.86 versus 0.88 ). When evaluating the remaining databases, given their large difference with the previous image set, the most appealing strategy was to retrain the CAD systems. However, since only the case condition was available, only the MIL-based system could be retrained. This scenario, which is common in real-world applications, demonstrates the better adaptation capabilities of the proposed approach. After retraining, our MIL-based system significantly outperformed the supervised one ( 0.86 versus 0.79 and 0.91 versus 0.85 , and p=0.0002 , respectively).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2014.2350539

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 130

Metadata

Authors
Melendez, J., van Ginneken, B., Maduskar, P., Philipsen, R. H. H. M., Reither, K., Breuninger, M., Adetifa, I. M. O., Maane, R., Ayles, H., & Sanchez, C. I.
Venue
IEEE Transactions on Medical Imaging
Published
2015-01
Volume
34
Issue
1
Pages
179-192
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2015103117
Cited by
130
References
5
FWCI
4.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Novel Multiple-Instance Learning-Based Approach to Computer-Aided Detection of Tuberculosis on Chest X-Rays. https://app.cochat.ai/papers/10.1109/tmi.2014.2350539
The paper
Melendez, J., van Ginneken, B., Maduskar, P., Philipsen, R. H. H. M., Reither, K., Breuninger, M., Adetifa, I. M. O., Maane, R., Ayles, H., & Sanchez, C. I. (2015). A Novel Multiple-Instance Learning-Based Approach to Computer-Aided Detection of Tuberculosis on Chest X-Rays. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2014.2350539

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.