The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Ultrasound Small Vessel Imaging With Block-Wise Adaptive Local Clutter Filtering
Abstract
Robust clutter filtering is essential for ultrasound small vessel imaging. Eigen-based clutter filtering techniques have recently shown great improvement in clutter rejection over conventional clutter filters in small animals. However, for in vivo human imaging, eigen-based clutter filtering can be challenging due to the complex spatially-varying tissue and noise characteristics. To address this challenge, we present a novel block-wise adaptive singular value decomposition (SVD) based clutter filtering technique. The proposed method divides the global plane wave data into overlapped local spatial segments, within which tissue signals are assumed to be locally coherent and noise locally stationary. This, in turn, enables effective separation of tissue, blood and noise via SVD. For each block, the proposed method adaptively determines the singular value cutoff thresholds based on local data statistics. Processing results from each block are redundantly combined to improve both the signal-to-noise-ratio (SNR) and the contrast-to-noise-ratio (CNR) of the small vessel perfusion image. Experimental results show that the proposed method achieved more than two-fold increase in SNR and more than three-fold increase in CNR in dB scale over the conventional global SVD filtering technique for an in vivo human native kidney study. The proposed method also showed substantial improvement in suppression of the depth-dependent background noise and better rejection of near field tissue clutter. The effects of different processing block size and block overlap percentage were systematically investigated as well as the tradeoff between imaging quality and computational cost.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Singular Value Thresholding Algorithm for Matrix Completion
Cai, J.-F., Candès, E. J., & Shen, Z. (2010) · SIAM Journal on Optimization · doi:10.1137/080738970 · Cited by 5,809
Halko, N., Martinsson, P. G., & Tropp, J. A. (2011) · SIAM Review · doi:10.1137/090771806 · Cited by 4,002
A Tutorial on Principal Component Analysis
Shlens, J. (2014) · arXiv (Cornell University) · doi:10.48550/arxiv.1404.1100 · Cited by 2,229
Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography
Montaldo, G., Tanter, M., Bercoff, J., Benech, N., & Fink, M. (2009) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1067 · Cited by 1,814
DISTRIBUTION OF EIGENVALUES FOR SOME SETS OF RANDOM MATRICES
Marčenko, V. A., & Pastur, L. A. (1967) · Mathematics of the USSR-Sbornik · doi:10.1070/sm1967v001n04abeh001994 · Cited by 1,713
Fixed point and Bregman iterative methods for matrix rank minimization
Ma, S., Goldfarb, D., & Chen, L. (2011) · Mathematical Programming · doi:10.1007/s10107-009-0306-5 · Cited by 1,048
Demene, C., Deffieux, T., Pernot, M., Osmanski, B.-F., Biran, V., Gennisson, J.-L., Sieu, L.-A., Bergel, A., Franqui, S., Correas, J.-M., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2428634 · Cited by 983
Functional ultrasound imaging of the brain
Macé, E., Montaldo, G., Cohen, I., Baulac, M., Fink, M., & Tanter, M. (2011) · Nature Methods · doi:10.1038/nmeth.1641 · Cited by 751
Ultrafast compound doppler imaging: providing full blood flow characterization
Bercoff, J., Montaldo, G., Loupas, T., Savery, D., Mézière, F., Fink, M., & Tanter, M. (2011) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2011.1780 · Cited by 510
Doppler Ultrasound: Physics, Instrumentation and Signal Processing
Evans, D. H. (2000) · Cited by 364
Functional ultrasound imaging of the brain: theory and basic principles
Mace, E., Montaldo, G., Osmanski, B.-F., Cohen, I., Fink, M., & Tanter, M. (2013) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2013.2592 · Cited by 327
Non-asymptotic Theory of Random Matrices: Extreme Singular Values
Rudelson, M., & Vershynin, R. (2011) · Proceedings of the International Congress of Mathematicians 2010 (ICM 2010) · doi:10.1142/9789814324359_0111 · Cited by 296
Clutter filter design for ultrasound color flow imaging
Bjaerum, S., Torp, H., & Kristoffersen, K. (2002) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.985705 · Cited by 257
Unbiased Risk Estimates for Singular Value Thresholding and Spectral Estimators
Candes, E. J., Sing-Long, C. A., & Trzasko, J. D. (2013) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2013.2270464 · Cited by 243
Self-citationEigen-based clutter filter design for ultrasound color flow imaging: a review
Yu, A., & Lovstakken, L. (2010) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2010.1521 · Cited by 204
Kadi, A. P., & Loupas, T. (1995) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.464825 · Cited by 110
Kruse, D. E., & Ferrara, K. W. (2002) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2002.1041080 · Cited by 97
Real-time adaptive clutter rejection filtering in color flow imaging using power method iterations
Løvstakken, L., Bjærum, S., Kristoffersen, K., Haaverstad, R., & Torp, H. G. (2006) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2006.1678188 · Cited by 69
Yu, A. C. H., & Cobbold, R. S. C. (2008) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2008.682 · Cited by 54
Colour flow and motion imaging
Evans, D. H. (2009) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim599 · Cited by 52
Adaptive clutter filtering for ultrasound color flow imaging
Yoo, Y. M., Managuli, R., & Kim, Y. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(03)01014-7 · Cited by 52
Cited by
Deep learning in ultrasound imaging
van Sloun, R. J. G., Cohen, R., & Eldar, Y. C. (2020) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2932116 · Cited by 316
Song, P., Trzasko, J. D., Manduca, A., Huang, R., Kadirvel, R., Kallmes, D. F., & Chen, S. (2018) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2017.2778941 · Cited by 285
Self-citation
Metadata
- Authors
- Song, P., Manduca, A., Trzasko, J. D., & Chen, S.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2017-01
- Volume
- 36
- Issue
- 1
- Pages
- 251-262
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2512639889
- Cited by
- 258
- References
- 21
- FWCI
- 16.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.