The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Isotropic Total Variation Regularization of Displacements in Parametric Image Registration
Open accessAbstract
-norm) is unable to correctly represent non-smooth displacement fields, that can, for example, occur at sliding interfaces in the thorax and abdomen in image time-series during respiration. In this paper, isotropic Total Variation (TV) regularization is used to enable accurate registration near such interfaces. We further develop the TV-regularization for parametric displacement fields and provide an efficient numerical solution scheme using the Alternating Directions Method of Multipliers (ADMM). The proposed method was successfully applied to four clinical databases which capture breathing motion, including CT lung and MR liver images. It provided accurate registration results for the whole volume. A key strength of our proposed method is that it does not depend on organ masks that are conventionally required by many algorithms to avoid errors at sliding interfaces. Furthermore, our method is robust to parameter selection, allowing the use of the same parameters for all tested databases. The average target registration error (TRE) of our method is superior (10% to 40%) to other techniques in the literature. It provides precise motion quantification and sliding detection with sub-pixel accuracy on the publicly available breathing motion databases (mean TREs of 0.95 mm for DIR 4D CT, 0.96 mm for DIR COPDgene, 0.91 mm for POPI databases).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boyd, S., Parikh, N., Chu, E., Peleato, B., & Eckstein, J. (2011) · Foundations and Trends® in Machine Learning · doi:10.1561/2200000016 · Cited by 17,075
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Cited by
TransMorph: Transformer for unsupervised medical image registration
Chen, J., Frey, E. C., He, Y., Segars, W. P., Li, Y., & Du, Y. (2022) · Medical Image Analysis · doi:10.1016/j.media.2022.102615 · Cited by 804
A review of deep learning-based three-dimensional medical image registration methods
Xiao, H., Teng, X., Liu, C., Li, T., Ren, G., Yang, R., Shen, D., & Cai, J. (2021) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-21-175 · Cited by 77
Metadata
- Authors
- Vishnevskiy, V., Gass, T., Szekely, G., Tanner, C., & Goksel, O.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2017-02
- Volume
- 36
- Issue
- 2
- Pages
- 385-395
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2520815785
- Cited by
- 240
- References
- 2
- FWCI
- 9.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Isotropic Total Variation Regularization of Displacements in Parametric Image Registration. https://app.cochat.ai/papers/10.1109/tmi.2016.2610583
- The paper
- Vishnevskiy, V., Gass, T., Szekely, G., Tanner, C., & Goksel, O. (2017). Isotropic Total Variation Regularization of Displacements in Parametric Image Registration. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2016.2610583
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.