The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Generative Adversarial Networks for Noise Reduction in Low-Dose CT
Abstract
Noise is inherent to low-dose CT acquisition. We propose to train a convolutional neural network (CNN) jointly with an adversarial CNN to estimate routine-dose CT images from low-dose CT images and hence reduce noise. A generator CNN was trained to transform low-dose CT images into routine-dose CT images using voxelwise loss minimization. An adversarial discriminator CNN was simultaneously trained to distinguish the output of the generator from routine-dose CT images. The performance of this discriminator was used as an adversarial loss for the generator. Experiments were performed using CT images of an anthropomorphic phantom containing calcium inserts, as well as patient non-contrast-enhanced cardiac CT images. The phantom and patients were scanned at 20% and 100% routine clinical dose. Three training strategies were compared: the first used only voxelwise loss, the second combined voxelwise loss and adversarial loss, and the third used only adversarial loss. The results showed that training with only voxelwise loss resulted in the highest peak signal-to-noise ratio with respect to reference routine-dose images. However, CNNs trained with adversarial loss captured image statistics of routine-dose images better. Noise reduction improved quantification of low-density calcified inserts in phantom CT images and allowed coronary calcium scoring in low-dose patient CT images with high noise levels. Testing took less than 10 s per CT volume. CNN-based low-dose CT noise reduction in the image domain is feasible. Training with an adversarial network improves the CNNs ability to generate images with an appearance similar to that of reference routine-dose CT images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Very Deep Convolutional Networks for Large-Scale Image Recognition
Simonyan, K., & Zisserman, A. (2014) · arXiv · doi:10.48550/arxiv.1409.1556 · Cited by 114,148
Adam: A Method for Stochastic Optimization
Kingma, D. P., & Ba, J. (2014) · arXiv · doi:10.48550/arxiv.1412.6980 · Cited by 98,946
Batch Normalization: Accelerating Deep Network Training by Reducing Internal Covariate Shift
Ioffe, S., & Szegedy, C. (2015) · arXiv · doi:10.48550/arxiv.1502.03167 · Cited by 27,818
Image-to-Image Translation with Conditional Adversarial Networks
Isola, P., Zhu, J.-Y., Zhou, T., & Efros, A. A. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.632 · Cited by 22,930
Labaca-Castro, R. (2023) · Machine Learning under Malware Attack · doi:10.1007/978-3-658-40442-0_9 · Cited by 19,272
GAN(Generative Adversarial Nets)
(2017) · Journal of Japan Society for Fuzzy Theory and Intelligent Informatics · doi:10.3156/jsoft.29.5_177_2 · Cited by 19,270
(2010) · Cited by 14,134
Photo-Realistic Single Image Super-Resolution Using a Generative Adversarial Network
Ledig, C., Theis, L., Huszar, F., Caballero, J., Cunningham, A., Acosta, A., Aitken, A., Tejani, A., Totz, J., Wang, Z., et al. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.19 · Cited by 12,696
Unsupervised representation learning with deep convolutional generative adversarial networks
Radford, A., Metz, L., & Chintala, S. (2015) · arXiv · doi:10.48550/arxiv.1511.06434 · Cited by 12,235
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
Quantification of coronary artery calcium using ultrafast computed tomography
Agatston, A. S., Janowitz, W. R., Hildner, F. J., Zusmer, N. R., Viamonte, M., & Detrano, R. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90282-t · Cited by 7,786 · cited 3×
“Hence, in all cases a clinical calcium threshold of 130 HU was used [35].”
MethodInfluentialA Review of Image Denoising Algorithms, with a New One
Buades, A., Coll, B., & Morel, J. M. (2005) · Multiscale Modeling & Simulation · doi:10.1137/040616024 · Cited by 4,083
Pearce, M. S., Salotti, J. A., Little, M. P., McHugh, K., Lee, C., Kim, K. P., Howe, N. L., Ronckers, C. M., Rajaraman, P., Craft, A. W., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60815-0 · Cited by 3,735
Goff, D. C., Lloyd-Jones, D. M., Bennett, G., Coady, S., D’Agostino, R. B., Gibbons, R., Greenland, P., Lackland, D. T., Levy, D., O’Donnell, C. J., et al. (2014) · Circulation · doi:10.1161/01.cir.0000437741.48606.98 · Cited by 3,697
Striving for Simplicity: The All Convolutional Net
Springenberg, J. T., Dosovitskiy, A., Brox, T., & Riedmiller, M. (2014) · arXiv · doi:10.48550/arxiv.1412.6806 · Cited by 3,447
Zhang, R., Isola, P., & Efros, A. A. (2016) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-46487-9_40 · Cited by 3,178
Yeboah, J., McClelland, R. L., Polonsky, T. S., Burke, G. L., Sibley, C. T., O’Leary, D., Carr, J. J., Goff, D. C., Greenland, P., & Herrington, D. M. (2012) · JAMA · doi:10.1001/jama.2012.9624 · Cited by 1,122
Estimated Radiation Dose Associated With Cardiac CT Angiography
Hausleiter, J. (2009) · JAMA · doi:10.1001/jama.2009.54 · Cited by 1,000
Automatic Segmentation of MR Brain Images With a Convolutional Neural Network
Moeskops, P., Viergever, M. A., Mendrik, A. M., de Vries, L. S., Benders, M. J. N. L., & Isgum, I. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2548501 · Cited by 861 · cited 1×
“require CNNs with large receptive fields [41], [42], noise”
BackgroundSelf-citationaLow-dose CT via convolutional neural network
Chen, H., Zhang, Y., Zhang, W., Liao, P., Li, K., Zhou, J., & Wang, G. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.000679 · Cited by 755
State of the Art: Iterative CT Reconstruction Techniques
Geyer, L. L., Schoepf, U. J., Meinel, F. G., Nance, J. W., Bastarrika, G., Leipsic, J. A., Paul, N. S., Rengo, M., Laghi, A., & De Cecco, C. N. (2015) · Radiology · doi:10.1148/radiol.2015132766 · Cited by 704
Medical Image Synthesis with Context-Aware Generative Adversarial Networks
Nie, D., Trullo, R., Lian, J., Petitjean, C., Ruan, S., Wang, Q., & Shen, D. (2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-66179-7_48 · Cited by 691
Semantic Segmentation using Adversarial Networks
Luc, P., Couprie, C., Chintala, S., & Verbeek, J. (2016) · arXiv · doi:10.48550/arxiv.1611.08408 · Cited by 611
Iterative reconstruction techniques for computed tomography Part 1: Technical principles
Willemink, M. J., de Jong, P. A., Leiner, T., de Heer, L. M., Nievelstein, R. A. J., Budde, R. P. J., & Schilham, A. M. R. (2013) · European Radiology · doi:10.1007/s00330-012-2765-y · Cited by 443
Self-citationDeep multi-scale video prediction beyond mean square error
Mathieu, M., Couprie, C., & LeCun, Y. (2015) · arXiv (Cornell University) · doi:10.48550/arxiv.1511.05440 · Cited by 339
Li, Z., Yu, L., Trzasko, J. D., Lake, D. S., Blezek, D. J., Fletcher, J. G., McCollough, C. H., & Manduca, A. (2013) · Medical Physics · doi:10.1118/1.4851635 · Cited by 299
Willemink, M. J., Leiner, T., de Jong, P. A., de Heer, L. M., Nievelstein, R. A. J., Schilham, A. M. R., & Budde, R. P. J. (2013) · European Radiology · doi:10.1007/s00330-012-2764-z · Cited by 268
Self-citationDeep Residual Learning for Compressed Sensing CT Reconstruction via Persistent Homology Analysis
Han, Y., Yoo, J., & Ye, J. C. (2016) · arXiv (Cornell University) · doi:10.48550/arxiv.1611.06391 · Cited by 161
Wolterink, J. M., Leiner, T., Takx, R. A. P., Viergever, M. A., & Išgum, I. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2412651 · Cited by 130
Self-citationMendrik, A. M., Vonken, E.-J. P. A., Rutten, A., Viergever, M. A., & van Ginneken, B. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2022368 · Cited by 116
Self-citationIšgum, I., Rutten, A., Prokop, M., & van Ginneken, B. (2007) · Medical Physics · doi:10.1118/1.2710548 · Cited by 106
Dilated Convolutional Neural Networks for Cardiovascular MR Segmentation in Congenital Heart Disease
Wolterink, J. M., Leiner, T., Viergever, M. A., & Išgum, I. (2017) · Lecture notes in computer science · doi:10.1007/978-3-319-52280-7_9 · Cited by 102
Self-citationGebhard, C., Fiechter, M., Fuchs, T. A., Ghadri, J. R., Herzog, B. A., Kuhn, F. P., Stehli, J., Müller, E., Kazakauskaitė, E., Gaemperli, O., et al. (2012) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.08.003 · Cited by 82
Rutten, A., Išgum, I., & Prokop, M. (2007) · Radiology · doi:10.1148/radiol.2461070006 · Cited by 68
Kim, C. W., & Kim, J. H. (2013) · Medical Physics · doi:10.1118/1.4830431 · Cited by 67
Low Radiation Dose Calcium Scoring: Evidence and Techniques
Baron, K. B., Choi, A., & Chen, M. Y. (2016) · Current Cardiovascular Imaging Reports · doi:10.1007/s12410-016-9373-1 · Cited by 63
Leßmann, N., Išgum, I., Setio, A. A. A., de Vos, B. D., Ciompi, F., de Jong, P. A., Oudkerk, M., Mali, W. P. T. M., Viergever, M. A., & van Ginneken, B. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2216978 · Cited by 63
Self-citationInfluence of iterative image reconstruction on CT-based calcium score measurements
van Osch, J. A. C., Mouden, M., van Dalen, J. A., Timmer, J. R., Reiffers, S., Knollema, S., Greuter, M. J. W., Ottervanger, J. P., & Jager, P. L. (2014) · International journal of cardiac imaging · doi:10.1007/s10554-014-0409-9 · Cited by 56
Efficient Low-Dose CT Denoising by Locally-Consistent Non-Local Means (LC-NLM)
Green, M., Marom, E. M., Kiryati, N., Konen, E., & Mayer, A. (2016) · Lecture notes in computer science · doi:10.1007/978-3-319-46726-9_49 · Cited by 36
Routine low-radiation-dose coronary computed tomography angiography
Al-Mallah, M. H., Aljizeeri, A. H., Alharthi, M. M. S., & Alsaileek, A. (2014) · European Heart Journal Supplements · doi:10.1093/eurheartj/suu024 · Cited by 32
den Harder, A. M., Wolterink, J. M., Willemink, M. J., Schilham, A. M. R., de Jong, P. A., Budde, R. P. J., Nathoe, H. M., Išgum, I., & Leiner, T. (2016) · European Journal of Radiology · doi:10.1016/j.ejrad.2016.09.028 · Cited by 28
Self-citationvan der Werf, N. R., Willemink, M. J., Willems, T. P., Greuter, M. J. W., & Leiner, T. (2017) · International journal of cardiac imaging · doi:10.1007/s10554-017-1061-y · Cited by 22
Self-citation
Cited by
A survey on Image Data Augmentation for Deep Learning
Shorten, C., & Khoshgoftaar, T. M. (2019) · Journal of Big Data · doi:10.1186/s40537-019-0197-0 · Cited by 13,203
Generative adversarial network in medical imaging: A review
Yi, X., Walia, E., & Babyn, P. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.101552 · Cited by 1,863
Yang, Q., Yan, P., Zhang, Y., Yu, H., Shi, Y., Mou, X., Kalra, M. K., Zhang, Y., Sun, L., & Wang, G. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2827462 · Cited by 1,630
Preparing Medical Imaging Data for Machine Learning
Willemink, M. J., Koszek, W. A., Hardell, C., Wu, J., Fleischmann, D., Harvey, H., Folio, L. R., Summers, R. M., Rubin, D. L., & Lungren, M. P. (2020) · Radiology · doi:10.1148/radiol.2020192224 · Cited by 1,020
ADMM-CSNet: A Deep Learning Approach for Image Compressive Sensing
Yang, Y., Sun, J., Li, H., & Xu, Z. (2020) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2018.2883941 · Cited by 908
Metadata
- Authors
- Wolterink, J. M., Leiner, T., Viergever, M. A., & Isgum, I.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2017-12
- Volume
- 36
- Issue
- 12
- Pages
- 2536-2545
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2617128058
- Cited by
- 1,037
- References
- 42
- FWCI
- 37.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.