CoChat

Automatic Segmentation of Acute Ischemic Stroke From DWI Using 3-D Fully Convolutional DenseNets

Zhang, Rongzhao, Zhao, Lei, Lou, Wutao, Abrigo, Jill M., Mok, Vincent C. T., Chu, Winnie C. W., Wang, Defeng, Shi, Lin · 2018 · IEEE Transactions on Medical Imaging
Cited by 209

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

Acute ischemic stroke is recognized as a common cerebral vascular disease in aging people. Accurate diagnosis and timely treatment can effectively improve the blood supply of the ischemic area and reduce the risk of disability or even death. Understanding the location and size of infarcts plays a critical role in the diagnosis decision. However, manual localization and quantification of stroke lesions are laborious and time-consuming. In this paper, we propose a novel automatic method to segment acute ischemic stroke from diffusion weighted images (DWIs) using deep 3-D convolutional neural networks (CNNs). Our method can efficiently utilize 3-D contextual information and automatically learn very discriminative features in an end-to-end and data-driven way. To relieve the difficulty of training very deep 3-D CNN, we equip our network with dense connectivity to enable the unimpeded propagation of information and gradients throughout the network. We train our model with Dice objective function to combat the severe class imbalance problem in data. A DWI data set containing 242 subjects (90 for training, 62 for validation, and 90 for testing) with various types of acute ischemic stroke was constructed to evaluate our method. Our model achieved high performance on various metrics (Dice similarity coefficient: 79.13%, lesionwise precision: 92.67%, and lesionwise F1 score: 89.25%), outperforming the other state-of-the-art CNN methods by a large margin. We also evaluated the model on ISLES2015-SSIS data set and achieved very competitive performance, which further demonstrated its generalization capacity. The proposed method is fast and accurate, demonstrating a good potential in clinical routines.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2018.2821244

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 209

Metadata

Authors
Zhang, R., Zhao, L., Lou, W., Abrigo, J. M., Mok, V. C. T., Chu, W. C. W., Wang, D., & Shi, L.
Venue
IEEE Transactions on Medical Imaging
Published
2018-09
Volume
37
Issue
9
Pages
2149-2160
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2795142235
Cited by
209
References
15
FWCI
12.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automatic Segmentation of Acute Ischemic Stroke From DWI Using 3-D Fully Convolutional DenseNets. https://app.cochat.ai/papers/10.1109/tmi.2018.2821244
The paper
Zhang, R., Zhao, L., Lou, W., Abrigo, J. M., Mok, V. C. T., Chu, W. C. W., Wang, D., & Shi, L. (2018). Automatic Segmentation of Acute Ischemic Stroke From DWI Using 3-D Fully Convolutional DenseNets. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2018.2821244

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.