Kinesthetic Sensing for the EMG Controlled "Boston Arm"
The DOI matches its Crossref record.
Abstract
The contribution of a novel cutaneous display of elbow angle to an amputee's ability to position an EMG-controlled externally powered elbow prosthesis was objectively evaluated. Comparisons were made between the amputee's positional control of his conventional mechanical cable-operated elbow and the EMG "Boston Arm"l elbow, with and without angle feedback, in REACHING tasks with vision occluded in all cases and with and without auditory occlusion. MATCHING tasks compared his ability to position the EMG limb to conform with the flexion of his normal (contralateral) elbow. Computer reduction of almost 9000 individual trials and analysis of variance indicated that for the EMG limb the tactile feedback with sound occluded reduced errors by 50 percent. Terminal device load did not significantly affect positioningperformance due to the force proprioception built into the Boston Arm. In comparison with the standard mechanical prosthesis, the EMG limb with feedback achieves virtually identical kinesthetic performance. The display is completely compatible with the EMG control, causes no discomfort to the wearer, and is not significantly degraded by the environmental conditions of the limb socket.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827
Sensory feedback in upper limb prosthetics
Antfolk, C., D’Alonzo, M., Rosén, B., Lundborg, G., Sebelius, F., & Cipriani, C. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.12.68 · Cited by 466
Myoelectric forearm prostheses: State of the art from a user-centered perspective
Peerdeman, B., Boere, D., Witteveen, H., Huis in `tVeld, R., Hermens, H., Stramigioli, S., Rietman, H., Veltink, P., & Misra, S. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.08.0161 · Cited by 469
A Review of Non-Invasive Sensory Feedback Methods for Transradial Prosthetic Hands
Stephens-Fripp, B., Alici, G., & Mutlu, R. (2018) · IEEE Access · doi:10.1109/access.2018.2791583 · Cited by 210
“This problem was identified early on in the Boston Arm prosthetic [9] where the authors introduced vibration feedback to give the user position information on the elbow joint of an EMG controlled prosthetic resulting in a performance comparable to that of the cable driven prosthetic.”
BackgroundVibro- and Electrotactile User Feedback on Hand Opening for Myoelectric Forearm Prostheses
Witteveen, H. J. B., Droog, E. A., Rietman, J. S., & Veltink, P. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2200678 · Cited by 150
Metadata
- Authors
- Mann, R., & Reimers, S.
- Venue
- IEEE Transactions on Man Machine Systems
- Published
- 1970-03
- Volume
- 11
- Issue
- 1
- Pages
- 110-115
- ISSN
- 0536-1540 (ISSN-L)
- OpenAlex
- W2116935093
- Cited by
- 108
- References
- 0
- FWCI
- 1.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Kinesthetic Sensing for the EMG Controlled "Boston Arm". https://app.cochat.ai/papers/10.1109/tmms.1970.299971
- The paper
- Mann, R., & Reimers, S. (1970). Kinesthetic Sensing for the EMG Controlled "Boston Arm". IEEE Transactions on Man Machine Systems. https://doi.org/10.1109/tmms.1970.299971
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.