NIST SP 800-90B Compliant Perpendicular Magnetic Tunnel Junction Based True Random Number Generator
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
True random number generators (TRNGs) are essential for applications such as hardware security and cryptographic protocols. Magnetically stabilized spin-transfer torque-perpendicular magnetic tunnel junctions (STT-pMTJs) have emerged as a promising candidate for TRNGs due to their rapid switching speed and low energy consumption. The switching speed could be controlled by the voltage amplitude, enabling high-quality bit generation with adjustable frequency. In previous studies, the quality of the generated bits is evaluated by NIST 800-22 standards, which are now considered outdated and insufficient for modern cryptographic requirements. In this work, we demonstrate a pMTJ-based TRNG with a low resistance-area (RA) product of 3.5 Ω•μm2and a tunnel magnetoresistance (TMR) ratio of 105%. Magnetization switching occurs in 2.70 ns with a probability of 50% at a current density of 3.38×10⁷ A/cm2. The generated bits achieve NIST SP 800-90B compliance with only a single XOR whitening step.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Recommendation for the Entropy Sources Used for Random Bit Generation
Turan, M. S., Barker, E., Kelsey, J., McKay, K. A., Baish, M. L., & Boyle, M. (2018) · NIST Special Publication 800-90B · doi:10.6028/nist.sp.800-90b · Cited by 489
Spin dice: A scalable truly random number generator based on spintronics
Fukushima, A., Seki, T., Yakushiji, K., Kubota, H., Imamura, H., Yuasa, S., & Ando, K. (2014) · Applied Physics Express · doi:10.7567/apex.7.083001 · Cited by 238
16.3 A 23Mb/s 23pJ/b fully synthesized true-random-number generator in 28nm and 65nm CMOS
Yang, K., Fick, D., Henry, M. B., Lee, Y., Blaauw, D., & Sylvester, D. (2014) · 2014 IEEE International Solid-State Circuits Conference Digest of Technical Papers (ISSCC) · doi:10.1109/isscc.2014.6757434 · Cited by 155
Choi, W. H., Lv, Y., Kim, J., Deshpande, A., Kang, G., Wang, J.-P., & Kim, C. H. (2014) · 2014 IEEE International Electron Devices Meeting · doi:10.1109/iedm.2014.7047039 · Cited by 128 · cited 1×
“Spintronic devices, particularly magnetic tunnel junctions (MTJs), offer a promising alternative due to their low power consumption and rapid switching capabilities [2]-[11].”
Self-citationLee, H., Ebrahimi, F., Amiri, P. K., & Wang, K. L. (2017) · AIP Advances · doi:10.1063/1.4978320 · Cited by 59
Schnitzspan, L., Kläui, M., & Jakob, G. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.20.024002 · Cited by 51
Rehm, L., Capriata, C. C. M., Misra, S., Smith, J. D., Pinarbasi, M., Malm, B. G., & Kent, A. D. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.024035 · Cited by 44
Magnetic-Tunnel-Junction-Based True Random-Number Generator with Enhanced Generation Rate
Chen, X., Zhang, J., & Xiao, J. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.18.l021002 · Cited by 27
Provably Secure Randomness Generation from Switching Probability of Magnetic Tunnel Junctions
Ng, H. J., Yang, S., Yao, Z., Yang, H., & Lim, C. C. W. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.034077 · Cited by 19
Rehm, L., Morshed, M. G., Misra, S., Shukla, A., Rakheja, S., Pinarbasi, M., Ghosh, A. W., & Kent, A. D. (2024) · Applied Physics Letters · doi:10.1063/5.0186810 · Cited by 19
Research works printed but not linked: 2
- 10.1145/2950067.2950108 · doi:10.1145/2950067.2950108
- Decision to Revise NIST SP 800-22 Rev. 1a | CSRC
Cited by
Jia, Q., Egan, S., Lv, Y., & Wang, J. (2026) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2026.3715464 · Cited by 1
“5 regime using the NIST SP 800-90B Entropy Assessment [38], [39].”
Self-citation
Metadata
- Authors
- Jia, Q., Egan, S., Lv, Y., & Wang, J.-P.
- Affiliations
- University of Minnesota (US)
- Deep Science Ventures,London,UK
- Venue
- 2025 IEEE 36th Magnetic Recording Conference (TMRC)
- Publisher
- IEEE
- Published
- 2025-07-28
- Pages
- 1-2
- OpenAlex
- W4415180321
- Cited by
- 1
- References
- 11
- Citations by year
- 2026: 1
- FWCI
- 2.46
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE Magnetic Recording Conference (TMRC) (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Condensed Matter Physics › Magnetic properties of thin films
- Physical Sciences › Computer Science › Hardware and Architecture › Physical Unclonable Functions (PUFs) and Hardware Security
- Physical Sciences › Computer Science › Artificial Intelligence › Cryptographic Implementations and Security
- Keywords
- true random number generator, perpendicular magnetic tunnel junctions, spin-transfer torque, magnetization reversal, NIST SP 800-90B, NIST SP 800-22, tunnel magnetoresistance, resistance-area product, hardware security, cryptographic randomness
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: NIST SP 800-90B Compliant Perpendicular Magnetic Tunnel Junction Based True Random Number Generator. https://app.cochat.ai/papers/10.1109/tmrc66824.2025.11192720
- The paper
- Jia, Q., Egan, S., Lv, Y., & Wang, J.-P. (2025). NIST SP 800-90B Compliant Perpendicular Magnetic Tunnel Junction Based True Random Number Generator. 2025 IEEE 36th Magnetic Recording Conference (TMRC). https://doi.org/10.1109/tmrc66824.2025.11192720
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.