Microwave-Based Noninvasive Concentration Measurements for Biomedical Applications

Hofmann, Maximilian, Fischer, Georg, Weigel, Robert, Kissinger, Dietmar·2013·IEEE Transactions on Microwave Theory and Techniques

Abstract

A Debye relaxation model for the permittivity of aqueous glucose solution is given up to 40 GHz. Measurements of aqueous solutions are compared with invasive measurements on over 40 blood samples. Reflection- and transmission-based techniques are explained, concerning the application in biomedical concentration measurements. Wideband measurements on different sensing structures are introduced. Reflection- and transmission-based sensors are applied to a six-port reflectometer, as well as a homodyne vector network analyzer.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmtt.2013.2250516

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 288

Metadata

Authors
Hofmann, M., Fischer, G., Weigel, R., & Kissinger, D.
Venue
IEEE Transactions on Microwave Theory and Techniques
Published
2013-05
Volume
61
Issue
5
Pages
2195-2204
ISSN
  • 0018-9480 (ISSN-L)
  • 1557-9670
OpenAlex
W2170700281
Cited by
288
References
1
FWCI
14.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Microwave-Based Noninvasive Concentration Measurements for Biomedical Applications. https://app.cochat.ai/papers/10.1109/tmtt.2013.2250516
The paper
Hofmann, M., Fischer, G., Weigel, R., & Kissinger, D. (2013). Microwave-Based Noninvasive Concentration Measurements for Biomedical Applications. IEEE Transactions on Microwave Theory and Techniques. https://doi.org/10.1109/tmtt.2013.2250516

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.