CoChat

Utilizing ECG-Based Heartbeat Classification for Hypertrophic Cardiomyopathy Identification

Open access
Rahman, Quazi Abidur, Tereshchenko, Larisa G., Kongkatong, Matthew, Abraham, Theodore, Abraham, M. Roselle, Shatkay, Hagit · 2015 · IEEE Transactions on NanoBioscience
Cited by 101

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Hypertrophic cardiomyopathy (HCM) is a cardiovascular disease where the heart muscle is partially thickened and blood flow is (potentially fatally) obstructed. A test based on electrocardiograms (ECG) that record the heart electrical activity can help in early detection of HCM patients. This paper presents a cardiovascular-patient classifier we developed to identify HCM patients using standard 10-second, 12-lead ECG signals. Patients are classified as having HCM if the majority of their recorded heartbeats are recognized as characteristic of HCM. Thus, the classifier's underlying task is to recognize individual heartbeats segmented from 12-lead ECG signals as HCM beats, where heartbeats from non-HCM cardiovascular patients are used as controls. We extracted 504 morphological and temporal features—both commonly used and newly-developed ones—from ECG signals for heartbeat classification. To assess classification performance, we trained and tested a random forest classifier and a support vector machine classifier using 5-fold cross validation. We also compared the performance of these two classifiers to that obtained by a logistic regression classifier, and the first two methods performed better than logistic regression. The patient-classification precision of random forests and of support vector machine classifiers is close to 0.85. Recall (sensitivity) and specificity are approximately 0.90. We also conducted feature selection experiments by gradually removing the least informative features; the results show that a relatively small subset of 264 highly informative features can achieve performance measures comparable to those achieved by using the complete set of features.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tnb.2015.2426213

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 101

Metadata

Authors
Rahman, Q. A., Tereshchenko, L. G., Kongkatong, M., Abraham, T., Abraham, M. R., & Shatkay, H.
Venue
IEEE Transactions on NanoBioscience
Published
2015-07
Volume
14
Issue
5
Pages
505-512
ISSN
  • 1536-1241 (ISSN-L)
  • 1558-2639
OpenAlex
W2095804932
Cited by
101
References
3
FWCI
4.24
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Utilizing ECG-Based Heartbeat Classification for Hypertrophic Cardiomyopathy Identification. https://app.cochat.ai/papers/10.1109/tnb.2015.2426213
The paper
Rahman, Q. A., Tereshchenko, L. G., Kongkatong, M., Abraham, T., Abraham, M. R., & Shatkay, H. (2015). Utilizing ECG-Based Heartbeat Classification for Hypertrophic Cardiomyopathy Identification. IEEE Transactions on NanoBioscience. https://doi.org/10.1109/tnb.2015.2426213

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.