The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Block-Based Neural Networks for Personalized ECG Signal Classification
Abstract
This paper presents evolvable block-based neural networks (BbNNs) for personalized ECG heartbeat pattern classification. A BbNN consists of a 2-D array of modular component NNs with flexible structures and internal configurations that can be implemented using reconfigurable digital hardware such as field-programmable gate arrays (FPGAs). Signal flow between the blocks determines the internal configuration of a block as well as the overall structure of the BbNN. Network structure and the weights are optimized using local gradient-based search and evolutionary operators with the rates changing adaptively according to their effectiveness in the previous evolution period. Such adaptive operator rate update scheme ensures higher fitness on average compared to predetermined fixed operator rates. The Hermite transform coefficients and the time interval between two neighboring R-peaks of ECG signals are used as inputs to the BbNN. A BbNN optimized with the proposed evolutionary algorithm (EA) makes a personalized heartbeat pattern classifier that copes with changing operating environments caused by individual difference and time-varying characteristics of ECG signals. Simulation results using the Massachusetts Institute of Technology/Beth Israel Hospital (MIT-BIH) arrhythmia database demonstrate high average detection accuracies of ventricular ectopic beats (98.1%) and supraventricular ectopic beats (96.6%) patterns for heartbeat monitoring, being a significant improvement over previously reported electrocardiogram (ECG) classification results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Learning representations by back-propagating errors
Rumelhart, D. E., Hinton, G. E., & Williams, R. J. (1986) · Nature · doi:10.1038/323533a0 · Cited by 31,892
Cited by
ECG beat classification using PCA, LDA, ICA and Discrete Wavelet Transform
Martis, R. J., Acharya, U. R., & Min, L. C. (2013) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.01.005 · Cited by 722
Heartbeat Classification Using Morphological and Dynamic Features of ECG Signals
Ye, C., Kumar, B. V. K. V., & Coimbra, M. T. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2213253 · Cited by 522
A novel application of deep learning for single-lead ECG classification
Mathews, S. M., Kambhamettu, C., & Barner, K. E. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.05.013 · Cited by 322
Convolutional Neural Networks for patient-specific ECG classification
Kiranyaz, S., Ince, T., Hamila, R., & Gabbouj, M. (2015) · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318926 · Cited by 309
Satija, U., Ramkumar, B., & Manikandan, M. S. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2877055 · Cited by 102
Metadata
- Authors
- Jiang, W., & Seong Kong, G.
- Venue
- IEEE Transactions on Neural Networks
- Published
- 2007-11
- Volume
- 18
- Issue
- 6
- Pages
- 1750-1761
- ISSN
- 1045-9227 (ISSN-L)
- 1941-0093
- OpenAlex
- W2101166342
- Cited by
- 366
- References
- 1
- FWCI
- 3.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Block-Based Neural Networks for Personalized ECG Signal Classification. https://app.cochat.ai/papers/10.1109/tnn.2007.900239
- The paper
- Jiang, W., & Seong Kong, G. (2007). Block-Based Neural Networks for Personalized ECG Signal Classification. IEEE Transactions on Neural Networks. https://doi.org/10.1109/tnn.2007.900239
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.