CoChat

Conceptual design of a proton computed tomography system for applications in proton radiation therapy

Schulte, R., Bashkirov, V., Tianfang Li, Zhengrong Liang, Mueller, K., Heimann, J., Johnson, L.R., Keeney, B., Sadrozinski, H.F.-W., Seiden, A., Williams, D.C., Lan Zhang, Zhang Li, Peggs, S., Satogata, T., Woody, C. · 2004 · IEEE Transactions on Nuclear Science
Cited by 224

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Proton computed tomography (pCT) has the potential to improve the accuracy of dose calculations for proton treatment planning, and will also be useful for pretreatment verification of patient positioning relative to the proton beam. A design study was performed to define the optimal approach to a pCT system based on specifications for applications in proton therapy. Conceptual and detailed design of a pCT system is presented; the system consists of a silicon-based particle tracking system and a crystal calorimeter to measure energy loss of individual protons. We discuss the formation of pCT images based on the reconstruction of volume electron density maps and the suitability of analytic and statistical algorithms for image reconstruction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tns.2004.829392

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 224

Metadata

Authors
Schulte, R., Bashkirov, V., Li, T., Liang, Z., Mueller, K., Heimann, J., Johnson, L. R., Keeney, B., Sadrozinski, H. F.-W., Seiden, A., Williams, D. C., Zhang, L., Li, Z., Peggs, S., Satogata, T., & Woody, C.
Venue
IEEE Transactions on Nuclear Science
Published
2004-06
Volume
51
Issue
3
Pages
866-872
ISSN
0018-9499 (ISSN-L)
OpenAlex
W2126636772
Cited by
224
References
10
FWCI
3.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Conceptual design of a proton computed tomography system for applications in proton radiation therapy. https://app.cochat.ai/papers/10.1109/tns.2004.829392
The paper
Schulte, R., Bashkirov, V., Li, T., Liang, Z., Mueller, K., Heimann, J., Johnson, L. R., Keeney, B., Sadrozinski, H. F.-W., Seiden, A., Williams, D. C., Zhang, L., Li, Z., Peggs, S., Satogata, T., & Woody, C. (2004). Conceptual design of a proton computed tomography system for applications in proton radiation therapy. IEEE Transactions on Nuclear Science. https://doi.org/10.1109/tns.2004.829392

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.