Model-based registration of X-ray mammograms and MR images of the female breast
The DOI matches its Crossref record.
Abstract
We present a new approach for automatic registration of X-ray mammograms and MR images. Multimodal breast cancer diagnosis is supported by automatic localization of small lesions, which are only visible in the mammograms or in the MR image. To cope with the huge deformation of the breast during mammography, a finite element model of the deformable behavior of the breast is applied during the registration. An evaluation of the registration with six clinical data sets resulted in an accurate localization with a mean displacement of 4.3 mm (/spl plusmn/1 mm) and 3.9 mm (/spl plusmn/1.7 mm) for predicting the lesion position in mammograms and in the MR images, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“Lastly, maybe the most important choice regards the boundary conditions and whether it is the interaction of compression plates and the breast [207,208,212,214 218], displacement loading [210,219] or both [211,213].”
BackgroundBreast Image Analysis for Risk Assessment, Detection, Diagnosis, and Treatment of Cancer
Giger, M. L., Karssemeijer, N., & Schnabel, J. A. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071812-152416 · Cited by 206
“A more automated approach was developed to relate 3D MRI to 2D X-rays using a homogeneous biomechanical model, for solving this rather complex registration task (141).”
MethodBreast MRI and X-ray mammography registration using gradient values
García, E., Diez, Y., Diaz, O., Lladó, X., Gubern-Mérida, A., Martí, R., Martí, J., & Oliver, A. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.02.013 · Cited by 26
MRI to X-ray mammography registration using a volume-preserving affine transformation
Mertzanidou, T., Hipwell, J., Cardoso, M. J., Zhang, X., Tanner, C., Ourselin, S., Bick, U., Huisman, H., Karssemeijer, N., & Hawkes, D. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.03.001 · Cited by 24
Metadata
- Authors
- Ruiter, N. V., Stotzka, R., Muller, T.-O., Gemmeke, H., Reichenbach, J. R., & Kaiser, W. A.
- Venue
- IEEE Transactions on Nuclear Science
- Published
- 2006-02
- Volume
- 53
- Issue
- 1
- Pages
- 204-211
- ISSN
- 0018-9499 (ISSN-L)
- OpenAlex
- W2145913256
- Cited by
- 100
- References
- 0
- FWCI
- 4.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.