The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
The Medipix3 Prototype, a Pixel Readout Chip Working in Single Photon Counting Mode With Improved Spectrometric Performance
Abstract
A prototype pixel detector readout chip has been developed with a new front-end architecture aimed at eliminating the spectral distortion produced by charge diffusion in highly segmented semiconductor detectors. In the new architecture neighbouring pixels communicate with one another. At the corner of each pixel summing circuits add the total charge deposited in each sub-group of 4 pixels. Arbitration logic assigns a hit to the summing circuit with the highest charge. In the case where incoming X-ray photons produce fluorescence-a particular issue in high-Z materials-the charge deposited by those fluorescent photons will be included in the charge sum provided that the deposition takes place within the volume of the pixels neighbouring the initial impact point. The chip is configurable such that either the dimensions of each detector pixel match those of one readout pixel or detector pixels are 4 times greater in area than the readout pixels. In the latter case event-by-event summing is still possible between the larger pixels. As well as this innovative analog front-end circuit, each pixel contains comparators, logic circuits and two 15-bit counters. When the larger detector pixels are used these counters can be configured to permit multiple thresholds in a pixel providing spectroscopic information. The prototype chip has been designed and manufactured in an 8-metal 0.13 mum CMOS technology. First measurements show an electronic pixel noise of ~ 72 e-rms (Single Pixel Mode) and ~ 140 e-rms (Charge Summing Mode).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cramming More Components onto Integrated Circuits (1965)
Moore, G. (2021) · Ideas That Created the Future · doi:10.7551/mitpress/12274.003.0027 · Cited by 6,241
Cramming More Components Onto Integrated Circuits
Moore, G. E. (1998) · Proceedings of the IEEE · doi:10.1109/jproc.1998.658762 · Cited by 5,926
Pixel detectors with local intelligence: an IC designer point of view
Krummenacher, F. (1991) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/0168-9002(91)90152-g · Cited by 256
Cited by
Vision 20/20: Single photon counting x‐ray detectors in medical imaging
Taguchi, K., & Iwanczyk, J. S. (2013) · Medical Physics · doi:10.1118/1.4820371 · Cited by 948
Radiation dose reduction in computed tomography: techniques and future perspective
Yu, L., Liu, X., Leng, S., Kofler, J. M., Ramirez-Giraldo, J. C., Qu, M., Christner, J., Fletcher, J. G., & McCollough, C. H. (2009) · Imaging in Medicine · doi:10.2217/iim.09.5 · Cited by 395
Advances in solid state photon detectors
Renker, D., & Lorenz, E. (2009) · Journal of Instrumentation · doi:10.1088/1748-0221/4/04/p04004 · Cited by 385
Badea, C. T., Clark, D. P., Holbrook, M., Srivastava, M., Mowery, Y., & Ghaghada, K. B. (2019) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab03e2 · Cited by 74
Metadata
- Authors
- Ballabriga, R., Campbell, M., Heijne, E. H. M., Llopart, X., & Tlustos, L.
- Venue
- IEEE Transactions on Nuclear Science
- Published
- 2007-10
- Volume
- 54
- Issue
- 5
- Pages
- 1824-1829
- ISSN
- 0018-9499 (ISSN-L)
- OpenAlex
- W2123232003
- Cited by
- 361
- References
- 3
- FWCI
- 17.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Medipix3 Prototype, a Pixel Readout Chip Working in Single Photon Counting Mode With Improved Spectrometric Performance. https://app.cochat.ai/papers/10.1109/tns.2007.906163
- The paper
- Ballabriga, R., Campbell, M., Heijne, E. H. M., Llopart, X., & Tlustos, L. (2007). The Medipix3 Prototype, a Pixel Readout Chip Working in Single Photon Counting Mode With Improved Spectrometric Performance. IEEE Transactions on Nuclear Science. https://doi.org/10.1109/tns.2007.906163
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.