Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 361

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

The Medipix3 Prototype, a Pixel Readout Chip Working in Single Photon Counting Mode With Improved Spectrometric Performance

Ballabriga, R., Campbell, M., Heijne, E. H. M., Llopart, X., Tlustos, L.·2007·IEEE Transactions on Nuclear Science

Abstract

A prototype pixel detector readout chip has been developed with a new front-end architecture aimed at eliminating the spectral distortion produced by charge diffusion in highly segmented semiconductor detectors. In the new architecture neighbouring pixels communicate with one another. At the corner of each pixel summing circuits add the total charge deposited in each sub-group of 4 pixels. Arbitration logic assigns a hit to the summing circuit with the highest charge. In the case where incoming X-ray photons produce fluorescence-a particular issue in high-Z materials-the charge deposited by those fluorescent photons will be included in the charge sum provided that the deposition takes place within the volume of the pixels neighbouring the initial impact point. The chip is configurable such that either the dimensions of each detector pixel match those of one readout pixel or detector pixels are 4 times greater in area than the readout pixels. In the latter case event-by-event summing is still possible between the larger pixels. As well as this innovative analog front-end circuit, each pixel contains comparators, logic circuits and two 15-bit counters. When the larger detector pixels are used these counters can be configured to permit multiple thresholds in a pixel providing spectroscopic information. The prototype chip has been designed and manufactured in an 8-metal 0.13 mum CMOS technology. First measurements show an electronic pixel noise of ~ 72 e-rms (Single Pixel Mode) and ~ 140 e-rms (Charge Summing Mode).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tns.2007.906163

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 361

Metadata

Authors
Ballabriga, R., Campbell, M., Heijne, E. H. M., Llopart, X., & Tlustos, L.
Venue
IEEE Transactions on Nuclear Science
Published
2007-10
Volume
54
Issue
5
Pages
1824-1829
ISSN
0018-9499 (ISSN-L)
OpenAlex
W2123232003
Cited by
361
References
3
FWCI
17.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Medipix3 Prototype, a Pixel Readout Chip Working in Single Photon Counting Mode With Improved Spectrometric Performance. https://app.cochat.ai/papers/10.1109/tns.2007.906163
The paper
Ballabriga, R., Campbell, M., Heijne, E. H. M., Llopart, X., & Tlustos, L. (2007). The Medipix3 Prototype, a Pixel Readout Chip Working in Single Photon Counting Mode With Improved Spectrometric Performance. IEEE Transactions on Nuclear Science. https://doi.org/10.1109/tns.2007.906163

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.