The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Advances in solid state photon detectors
Open accessAbstract
Semiconductor photodiodes were developed in the early `Forties approximately at the time when the photomultiplier tube became a commercial product (RCA 1939). Only in recent years, with the invention of the Geiger-mode avalanche photodiodes, have the semiconductor photo detectors reached sensitivity comparable to that of photomultiplier tubes. The evolution started in the `Sixties with the p-i-n (PIN) photodiode, a very successful device, which is still used in many detectors for high energy physics and a large number of other applications like radiation detection and medical imaging. The next step was the development of the avalanche photodiode (APD) leading to a substantial reduction of noise but not yet achieving single photon response. The weakest light flashes that can be detected by the PIN diode need to contain several hundreds of photons. An improvement of the sensitivity by 2 orders of magnitude was achieved by the development of the avalanche photodiode, a device with internal gain. At the end of the millennium, the semiconductor detectors evolved with the Geiger-mode avalanche photodiode into highly sensitive devices, which have an internal gain comparable to the gain of photomultiplier tubes and a response to single photons. A review of the semiconductor photo detector design and development, the properties and problems, some applications and a speculative outlook on the future evolution will be presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new recombination model for device simulation including tunneling
Hurkx, G. A. M., Klaassen, D. B. M., & Knuvers, M. P. G. (1992) · IEEE Transactions on Electron Devices · doi:10.1109/16.121690 · Cited by 938
Silicon photomultiplier and its possible applications
Buzhan, P., Dolgoshein, B., Filatov, L., Ilyin, A., Kantzerov, V., Kaplin, V., Karakash, A., Kayumov, F., Klemin, S., Popova, E., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)00749-6 · Cited by 636
Broennimann, C., Eikenberry, E. F., Henrich, B., Horisberger, R., Huelsen, G., Pohl, E., Schmitt, B., Schulze‐Briese, C., Suzuki, M., Tomizaki, T., et al. (2006) · Journal of Synchrotron Radiation · doi:10.1107/s0909049505038665 · Cited by 488
The distribution of gains in uniformly multiplying avalanche photodiodes: Theory
McIntyre, R. J. (1972) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1972.17485 · Cited by 478
Ionization Rates of Holes and Electrons in Silicon
Lee, C. A., Logan, R. A., Batdorf, R. L., Kleimack, J. J., & Wiegmann, W. (1964) · Physical Review · doi:10.1103/physrev.134.a761 · Cited by 477
Ballabriga, R., Campbell, M., Heijne, E. H. M., Llopart, X., & Tlustos, L. (2007) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2007.906163 · Cited by 361
Principles and features of single-photon avalanche diode arrays
Zappa, F., Tisa, S., Tosi, A., & Cova, S. (2007) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2007.06.021 · Cited by 329
Evolution and prospects for single-photon avalanche diodes and quenching circuits
Cova, S., Ghioni, M., Lotito, A., Rech, I., & Zappa, F. (2004) · Journal of Modern Optics · doi:10.1080/09500340408235272 · Cited by 322
On the bremsstrahlung origin of hot-carrier-induced photons in silicon devices
Lacaita, A. L., Zappa, F., Bigliardi, S., & Manfredi, M. (1993) · IEEE Transactions on Electron Devices · doi:10.1109/16.199363 · Cited by 288
Pichler, B. J., Wehrl, H. F., Kolb, A., & Judenhofer, M. S. (2008) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2008.02.001 · Cited by 258
Cited by
Invited Review Article: Single-photon sources and detectors
Eisaman, M. D., Fan, J., Migdall, A., & Polyakov, S. V. (2011) · Review of Scientific Instruments · doi:10.1063/1.3610677 · Cited by 1,358
Advances in InGaAs/InP single-photon detector systems for quantum communication
Zhang, J., Itzler, M. A., Zbinden, H., & Pan, J.-W. (2015) · Light: Science & Applications · doi:10.1038/lsa.2015.59 · Cited by 436
Esmaeil Zadeh, I., Chang, J., Los, J. W. N., Gyger, S., Elshaari, A. W., Steinhauer, S., Dorenbos, S. N., & Zwiller, V. (2021) · Applied Physics Letters · doi:10.1063/5.0045990 · Cited by 331
The digital silicon photomultiplier — Principle of operation and intrinsic detector performance
Frach, T., Prescher, G., Degenhardt, C., de Gruyter, R., Schmitz, A., & Ballizany, R. (2009) · 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) · doi:10.1109/nssmic.2009.5402143 · Cited by 317
Metadata
- Authors
- Renker, D., & Lorenz, E.
- Venue
- Journal of Instrumentation
- Publisher
- IOP Publishing
- Published
- 2009-04-07
- Volume
- 4
- Issue
- 04
- Pages
- P04004-P04004
- ISSN
- 1748-0221 (ISSN-L)
- OpenAlex
- W2034937129
- Cited by
- 385
- References
- 17
- FWCI
- 14.83
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Advances in solid state photon detectors. https://app.cochat.ai/papers/10.1088/1748-0221/4/04/p04004
- The paper
- Renker, D., & Lorenz, E. (2009). Advances in solid state photon detectors. Journal of Instrumentation. https://doi.org/10.1088/1748-0221/4/04/p04004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.