A BCI-based environmental controller for the motion-disabled
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
With the development of brain-computer interface (BCI) technology, researchers are now attempting to put current BCI techniques into practical application. This paper presents an environmental controller using a BCI technique based on steady-state visual evoked potential. The system is composed of a stimulator, a digital signal processor, and a trainable infrared remote-controller. The attractive features of this system include noninvasive signal recording, little training requirement, and a high information transfer rate. Our test results have shown that this system can distinguish at least 48 targets and provide a transfer rate up to 68 b/min. The system has been applied to the control of an electric apparatus successfully.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Human Brain Electrophysiology: Evoked Potentials and Evoked Magnetic Fields in Science and Medicine
Regan, D. M. (1989) · Medical Entomology and Zoology · Cited by 1,300
An EEG-based brain-computer interface for cursor control
Wolpaw, J. R., McFarland, D. J., Neat, G. W., & Forneris, C. A. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90040-b · Cited by 1,114
Design and implementation of a brain-computer interface with high transfer rates
Cheng, M., Gao, X., Gao, S., & Xu, D. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.803536 · Cited by 818
Self-citationBrain-computer interfaces based on the steady-state visual-evoked response
Middendorf, M., McMillan, G., Calhoun, G., & Jones, K. S. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847819 · Cited by 685
Current trends in Graz brain-computer interface (BCI) research
Pfurtscheller, G., Neuper, C., Guger, C., Harkam, W., Ramoser, H., Schlogl, A., Obermaier, B., & Pregenzer, M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847821 · Cited by 518
Multichannel EEG-based brain-computer communication
Wolpaw, J. R., & McFarland, D. J. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90135-x · Cited by 449
Brain-computer interface research at the Wadsworth Center
Wolpaw, J. R., McFarland, D. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847823 · Cited by 440
The brain response interface: communication through visually-induced electrical brain responses
Sutter, E. E. (1992) · Journal of Microcomputer Applications · doi:10.1016/0745-7138(92)90045-7 · Cited by 417
EEG-based communication: a pattern recognition approach
Penny, W. D., Roberts, S. J., Curran, E. A., & Stokes, M. J. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847820 · Cited by 221
An EEG-based cursor control system
Ming, C., & Shangkai, G. (2003) · Proceedings of the First Joint BMES/EMBS Conference. 1999 IEEE Engineering in Medicine and Biology 21st Annual Conference and the 1999 Annual Fall Meeting of the Biomedical Engineering Society (Cat. No.99CH37015) · doi:10.1109/iembs.1999.802747 · Cited by 50
EEG-based control for human-computer interaction
Calhoun, G. L., & McMillan, G. R. (2002) · Proceedings Third Annual Symposium on Human Interaction with Complex Systems. HICS'96 · doi:10.1109/huics.1996.549486 · Cited by 34
Cited by
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
“frequency of visual stimulation is below 6 Hz, while SSVEPs occur in reaction to stimuli of a higher frequency [101,104].”
BackgroundSteady-state visually evoked potentials: Focus on essential paradigms and future perspectives
Vialatte, F.-B., Maurice, M., Dauwels, J., & Cichocki, A. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2009.11.005 · Cited by 1,066
Bashashati, A., Fatourechi, M., Ward, R. K., & Birch, G. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r03 · Cited by 907
Frequency recognition based on canonical correlation analysis for SSVEP-based BCIs
Lin, Z., Zhang, C., Wu, W., & Gao, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889197 · Cited by 867
Self-citationCombining brain-computer interfaces and assistive technologies: state-of-the-art and challenges
Millán, J. D. R. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00161 · Cited by 866
Metadata
- Authors
- Gao, X., Xu, D., Cheng, M., & Gao, S.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2003-06
- Volume
- 11
- Issue
- 2
- Pages
- 137-140
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2102837100
- Cited by
- 637
- References
- 12
- FWCI
- 5.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.