A BCI-based environmental controller for the motion-disabled
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
With the development of brain-computer interface (BCI) technology, researchers are now attempting to put current BCI techniques into practical application. This paper presents an environmental controller using a BCI technique based on steady-state visual evoked potential. The system is composed of a stimulator, a digital signal processor, and a trainable infrared remote-controller. The attractive features of this system include noninvasive signal recording, little training requirement, and a high information transfer rate. Our test results have shown that this system can distinguish at least 48 targets and provide a transfer rate up to 68 b/min. The system has been applied to the control of an electric apparatus successfully.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Human Brain Electrophysiology: Evoked Potentials and Evoked Magnetic Fields in Science and Medicine
Regan, D. M. (1989) · Medical Entomology and Zoology · Cited by 1,300
An EEG-based brain-computer interface for cursor control
Wolpaw, J. R., McFarland, D. J., Neat, G. W., & Forneris, C. A. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90040-b · Cited by 1,114
Design and implementation of a brain-computer interface with high transfer rates
Cheng, M., Gao, X., Gao, S., & Xu, D. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.803536 · Cited by 818
Self-citationBrain-computer interfaces based on the steady-state visual-evoked response
Middendorf, M., McMillan, G., Calhoun, G., & Jones, K. S. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847819 · Cited by 685
Current trends in Graz brain-computer interface (BCI) research
Pfurtscheller, G., Neuper, C., Guger, C., Harkam, W., Ramoser, H., Schlogl, A., Obermaier, B., & Pregenzer, M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847821 · Cited by 518
Multichannel EEG-based brain-computer communication
Wolpaw, J. R., & McFarland, D. J. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90135-x · Cited by 449
Brain-computer interface research at the Wadsworth Center
Wolpaw, J. R., McFarland, D. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847823 · Cited by 440
The brain response interface: communication through visually-induced electrical brain responses
Sutter, E. E. (1992) · Journal of Microcomputer Applications · doi:10.1016/0745-7138(92)90045-7 · Cited by 417
EEG-based communication: a pattern recognition approach
Penny, W. D., Roberts, S. J., Curran, E. A., & Stokes, M. J. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847820 · Cited by 221
Cited by
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
“frequency of visual stimulation is below 6 Hz, while SSVEPs occur in reaction to stimuli of a higher frequency [101,104].”
BackgroundSteady-state visually evoked potentials: Focus on essential paradigms and future perspectives
Vialatte, F.-B., Maurice, M., Dauwels, J., & Cichocki, A. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2009.11.005 · Cited by 1,066
Bashashati, A., Fatourechi, M., Ward, R. K., & Birch, G. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r03 · Cited by 907
Frequency recognition based on canonical correlation analysis for SSVEP-based BCIs
Lin, Z., Zhang, C., Wu, W., & Gao, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889197 · Cited by 867
Self-citationCombining brain-computer interfaces and assistive technologies: state-of-the-art and challenges
Millán, J. D. R. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00161 · Cited by 866
Brain-Computer Interfaces in Medicine
Shih, J. J., Krusienski, D. J., & Wolpaw, J. R. (2012) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2011.12.008 · Cited by 724
Frequency Recognition Based on Canonical Correlation Analysis for SSVEP-Based BCIs
Lin, Z., Zhang, C., Wu, W., & Gao, X. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886577 · Cited by 724
Self-citationA Survey of Stimulation Methods Used in SSVEP-Based BCIs
Zhu, D., Bieger, J., Garcia Molina, G., & Aarts, R. M. (2010) · Computational Intelligence and Neuroscience · doi:10.1155/2010/702357 · Cited by 654
EMG and EOG artifacts in brain computer interface systems: A survey
Fatourechi, M., Bashashati, A., Ward, R. K., & Birch, G. E. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.10.019 · Cited by 638
A practical VEP-based brain-computer interface
Wang, Y., Wang, R., Gao, X., Hong, B., & Gao, S. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875576 · Cited by 617
Self-citationMultiple Channel Detection of Steady-State Visual Evoked Potentials for Brain-Computer Interfaces
Friman, O., Volosyak, I., & Graser, A. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889160 · Cited by 541
Müller-Putz, G. R., Scherer, R., Brauneis, C., & Pfurtscheller, G. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/008 · Cited by 534
Clinical Applications of Brain-Computer Interfaces: Current State and Future Prospects
Mak, J. N., & Wolpaw, J. R. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2035356 · Cited by 509
Visual and Auditory Brain–Computer Interfaces
Gao, S., Wang, Y., Gao, X., & Hong, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2300164 · Cited by 449
Self-citationBrain-Computer Interfaces Based on Visual Evoked Potentials
Wang, Y., Gao, X., Hong, B., Jia, C., & Gao, S. (2008) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2008.923958 · Cited by 423
“Using such a stimulator, a 48-target BCI was reported in [8].”
MethodSelf-citationBrain–computer interface systems: progress and prospects
Allison, B. Z., Wolpaw, E. W., & Wolpaw, J. R. (2007) · Expert Review of Medical Devices · doi:10.1586/17434440.4.4.463 · Cited by 420
An improved P300-based brain-computer interface
Serby, H., Yom-Tov, E., & Inbar, G. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.841878 · Cited by 403
EEG-Based Brain-Controlled Mobile Robots: A Survey
Bi, L., Fan, X.-A., & Liu, Y. (2013) · IEEE Transactions on Human-Machine Systems · doi:10.1109/tsmcc.2012.2219046 · Cited by 386
Guest editorial brain-computer interface technology: a review of the second international meeting
Vaughan, T. M. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814799 · Cited by 352
Towards an independent brain–computer interface using steady state visual evoked potentials
Allison, B. Z., McFarland, D. J., Schalk, G., Zheng, S. D., Jackson, M. M., & Wolpaw, J. R. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.09.121 · Cited by 327
Kübler, A., Furdea, A., Halder, S., Hammer, E. M., Nijboer, F., & Kotchoubey, B. (2009) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2008.04122.x · Cited by 303
A high-ITR SSVEP-based BCI speller
Chen, X., Chen, Z., Gao, S., & Gao, X. (2014) · Brain-Computer Interfaces · doi:10.1080/2326263x.2014.944469 · Cited by 301
Self-citationA Comprehensive Survey of Brain Interface Technology Designs
Mason, S. G., Bashashati, A., Fatourechi, M., Navarro, K. F., & Birch, G. E. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9170-0 · Cited by 299
Brain–Computer Interfaces: A Gentle Introduction
Graimann, B., Allison, B., & Pfurtscheller, G. (2009) · The Frontiers Collection · doi:10.1007/978-3-642-02091-9_1 · Cited by 298
Steady-state somatosensory evoked potentials: suitable brain signals for brain-computer interfaces?
Muller-Putz, G. R., Scherer, R., Neuper, C., & Pfurtscheller, G. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.863842 · Cited by 288
Open Access Dataset for EEG+NIRS Single-Trial Classification
Shin, J., von Luhmann, A., Blankertz, B., Kim, D.-W., Jeong, J., Hwang, H.-J., & Muller, K.-R. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2628057 · Cited by 287
A Real-Time Wireless Brain–Computer Interface System for Drowsiness Detection
Lin, C.-T., Chang, C.-J., Lin, B.-S., Hung, S.-H., Chao, C.-F., & Wang, I.-J. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2046415 · Cited by 282
L1-Regularized Multiway Canonical Correlation Analysis for SSVEP-Based BCI
Zhang, Y., Zhou, G., Jin, J., Wang, M., Wang, X., & Cichocki, A. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2279680 · Cited by 267
Trejo, L. J., Rosipal, R., & Matthews, B. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875578 · Cited by 267
Liao, L.-D., Chen, C.-Y., Wang, I.-J., Chen, S.-F., Li, S.-Y., Chen, B.-W., Chang, J.-Y., & Lin, C.-T. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-5 · Cited by 258
VEP-based brain-computer interfaces: time, frequency, and code modulations [Research Frontier
Bin, G., Gao, X., Wang, Y., Hong, B., & Gao, S. (2009) · IEEE Computational Intelligence Magazine · doi:10.1109/mci.2009.934562 · Cited by 256
Self-citationA Dynamically Optimized SSVEP Brain–Computer Interface (BCI) Speller
Yin, E., Zhou, Z., Jiang, J., Yu, Y., & Hu, D. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2320948 · Cited by 254
A Self-Paced and Calibration-Less SSVEP-Based Brain–Computer Interface Speller
Cecotti, H. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039594 · Cited by 253
Development of an SSVEP-based BCI spelling system adopting a QWERTY-style LED keyboard
Hwang, H.-J., Lim, J.-H., Jung, Y.-J., Choi, H., Lee, S. W., & Im, C.-H. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.04.011 · Cited by 251
“The minimum frequency resolution of SSVEPs investigated so far was approximately 0.2 Hz (Gao et al., 2003).”
InfluentialNoninvasive Brain-Computer Interfaces Based on Sensorimotor Rhythms
He, B., Baxter, B., Edelman, B. J., Cline, C. C., & Ye, W. W. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2407272 · Cited by 233
“Of these, while the steady-state visual evoked potential (SSVEP)based BCI can provide many commands [26], the SMR-”
Ica: a potential tool for bci systems
Kachenoura, A., Albera, L., Senhadji, L., & Comon, P. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408442 · Cited by 225
“Authors also showed that their method had been successfully applied to a BCI-based environmental controller presented in [22].”
MethodA novel hybrid BCI speller based on the incorporation of SSVEP into the P300 paradigm
Yin, E., Zhou, Z., Jiang, J., Chen, F., Liu, Y., & Hu, D. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026012 · Cited by 225
“In some other studies, only one-channel EEG signals were used for the SSVEP detection by a simple power spectral density (PSD) analysis [28].”
MethodHuggins, J. E., Wren, P. A., & Gruis, K. L. (2011) · Amyotrophic Lateral Sclerosis · doi:10.3109/17482968.2011.572978 · Cited by 215
“BCIs have enabled individuals to spell messages (3 – 5), operate an on-screen mouse (6 – 8), and control environmental features (9,10).”
Background(2013) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-52901-5.00006-x · Cited by 212
Stimulator selection in SSVEP-based BCI
Wu, Z., Lai, Y., Xia, Y., Wu, D., & Yao, D. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.01.004 · Cited by 192
“[3] Gao XR, Xu DF, Cheng M, Gao SK.”
BackgroundMethodInfluentialHow Many People Could Use an SSVEP BCI?
Guger, C., Allison, B. Z., Großwindhager, B., Prückl, R., Hintermüller, C., Kapeller, C., Bruckner, M., Krausz, G., & Edlinger, G. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00169 · Cited by 176
“…(EEG): event-related desynchronization/synchronization (ERD/ERS), P300, or steady-state visual evoked potential (SSVEP; Middendorf et al., 2000; Wolpaw et al., 2002; Gao et al., 2003; Guger et al., 2003, 2009, 2012a; Sellers et al., 2006; Pfurtscheller et al., 2010; Ortner et al., 2011).”
BackgroundBCI Demographics II: How Many (and What Kinds of) People Can Use a High-Frequency SSVEP BCI?
Volosyak, I., Valbuena, D., Luth, T., Malechka, T., & Graser, A. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2121919 · Cited by 175
“This measure depends on three factors: speed, accuracy, and number of targets, which can vary from two [13] up to 48 [14].”
BackgroundLin, S., Liu, J., Li, W., Wang, D., Huang, Y., Jia, C., Li, Z., Murtaza, M., Wang, H., Song, J., et al. (2019) · Nano Letters · doi:10.1021/acs.nanolett.9b02019 · Cited by 171
Biosensor Technologies for Augmented Brain–Computer Interfaces in the Next Decades
Liao, L.-D., Lin, C.-T., McDowell, K., Wickenden, A. E., Gramann, K., Jung, T.-P., Ko, L.-W., & Chang, J.-Y. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2012.2184829 · Cited by 169
A Speedy Hybrid BCI Spelling Approach Combining P300 and SSVEP
Yin, E., Zhou, Z., Jiang, J., Chen, F., Liu, Y., & Hu, D. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2281976 · Cited by 167
“Several different electroencephalogram (EEG) signals can be used for spelling in BCIs, such as P300 event-related potential (ERP) [4], steady-state visually evoked potential (SSVEP) [5], and sensorimotor rhythm”
MethodA brain–computer interface using motion-onset visual evoked potential
Guo, F., Hong, B., Gao, X., & Gao, S. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/4/011 · Cited by 163
“Employing a coding scheme in the spectral domain, Gao et al [7, 8] and Middendorf et al [9] reported a method for discriminating the visual targets flashing at different frequencies by using spectral analysis of a steady-state VEP (SSVEP) signal, which provided an even more robust way of determining…”
MethodSelf-citationYuan, P., Gao, X., Allison, B., Wang, Y., Bin, G., & Gao, S. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026014 · Cited by 160
“T may be fixed, such as in classical P300 BCIs (e.g., Farwell and Donchin 1988), or may require testing, such as if the system continues monitoring the user’s brain activity until reaching an adequate accuracy threshold (Gao et al 2003, Jin et al 2011).”
BackgroundSelf-citationAn adaptive P300-based control system
Jin, J., Allison, B. Z., Sellers, E. W., Brunner, C., Horki, P., Wang, X., & Neuper, C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036006 · Cited by 158
“Untrained subjects have used BCIs based on SSVEPs in speller systems (Gao et al 2003, Friman et al 2007, Sugiarto et al 2009).”
MethodA Collaborative Brain-Computer Interface for Improving Human Performance
Wang, Y., & Jung, T.-P. (2011) · PLoS ONE · doi:10.1371/journal.pone.0020422 · Cited by 147
“In practice, portable data processing platforms such as a digital signal processor (DSP) platform can be integrated into the EEG recording device to reduce the overall system cost, and improve system practicality [29].”
Lin, C.-T., Ko, L.-W., Chang, M.-H., Duann, J.-R., Chen, J.-Y., Su, T.-P., & Jung, T.-P. (2010) · Gerontology · doi:10.1159/000230807 · Cited by 133
Li, G., & Zhang, D. (2016) · PLOS ONE · doi:10.1371/journal.pone.0150667 · Cited by 80
“Even though SSVEP can be elicited by visual stimulation with a wide range of frequencies from 1–100 Hz, the better SSVEP performance is achieved under visual stimulation with lower frequencies range of 6–15 Hz in general [12, 13].”
BackgroundNovel semi-dry electrodes for brain–computer interface applications
Wang, F., Li, G., Chen, J., Duan, Y., & Zhang, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046021 · Cited by 77
Benchmarking Brain-Computer Interfaces Outside the Laboratory: The Cybathlon 2016
Novak, D., Sigrist, R., Gerig, N. J., Wyss, D., Bauer, R., Götz, U., & Riener, R. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00756 · Cited by 41
“…a desired BCI command by looking at its corresponding part of the screen, and the BCI recognizes the command by measuring the dominant frequency of the visual cortex’s EEG activity (Middendorf et al., 2000; Gao et al., 2003; Pfurtscheller et al., 2010; Ortner et al., 2011; Sakurada et al., 2013).”
BackgroundMondada, L., Karim, M. E., & Mondada, F. (2016) · Swarm Intelligence · doi:10.1007/s11721-016-0127-0 · Cited by 16
Metadata
- Authors
- Gao, X., Xu, D., Cheng, M., & Gao, S.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2003-06
- Volume
- 11
- Issue
- 2
- Pages
- 137-140
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2102837100
- Cited by
- 637
- References
- 12
- FWCI
- 5.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.