Conversion of EEG activity into cursor movement by a brain-computer interface (BCI)
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
The Wadsworth electroencephalogram (EEG)-based brain-computer interface (BCI) uses amplitude in mu or beta frequency bands over sensorimotor cortex to control cursor movement. Trained users can move the cursor in one or two dimensions. The primary goal of this research is to provide a new communication and control option for people with severe motor disabilities. Currently, cursor movements in each dimension are determined 10 times/s by an empirically derived linear function of one or two EEG features (i.e., spectral bands from different electrode locations). This study used offline analysis of data collected during system operation to explore methods for improving the accuracy of cursor movement. The data were gathered while users selected among three possible targets by controlling vertical [i.e., one-dimensional (1-D)] cursor movement. The three methods analyzed differ in the dimensionality of the cursor movement [1-D versus two-dimensional (2-D)] and in the type of the underlying function (linear versus nonlinear). We addressed two questions: Which method is best for classification (i.e., to determine from the EEG which target the user wants to hit)? How does the number of EEG features affect the performance of each method? All methods reached their optimal performance with 10-20 features. In offline simulation, the 2-D linear method and the 1-D nonlinear method improved performance significantly over the 1-D linear method. The 1-D linear method did not do so. These offline results suggest that the 1-D nonlinear or the 2-D linear cursor function will improve online operation of the BCI system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural networks for pattern recognition
(1994) · Choice Reviews Online · doi:10.5860/choice.31-5500 · Cited by 18,538
Neural Networks for Pattern Recognition
Bishop, C. M. (1995) · doi:10.1093/oso/9780198538493.001.0001 · Cited by 12,287
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 1×
“those that use time-domain EEG components (e.g., [2] and [ 5 ]) and those that use frequency-domain components (e.g., [10] and [14]–[16]).”
BackgroundDevijver, P. A., & Kittler, J. (1982) · Prentice-Hall International eBooks · Cited by 2,910
Design and Analysis of Experiments
Montgomery, D. C. (1976) · Cited by 1,962
Electroencephalography: Basic Principles, Clinical Applications and Related Fields
Torres, F. (1983) · Archives of Neurology · doi:10.1001/archneur.1983.04050030085025 · Cited by 1,812
Calculating the Singular Values and Pseudo-Inverse of a Matrix
Golub, G., & Kahan, W. (1965) · Journal of the Society for Industrial and Applied Mathematics Series B Numerical Analysis · doi:10.1137/0702016 · Cited by 1,786
Design and Analysis of Experiments.
Kupper, L. L., & Montgomery, D. C. (1978) · Journal of the American Statistical Association · doi:10.2307/2286559 · Cited by 1,728
American Electroencephalographic Society Guidelines for Standard Electrode Position Nomenclature
&NA; (1991) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199104000-00007 · Cited by 1,050
Spatial filter selection for EEG-based communication
McFarland, D. J., McCane, L. M., David, S. V., & Wolpaw, J. R. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00022-2 · Cited by 936
Self-citation
Cited by
Bashashati, A., Fatourechi, M., Ward, R. K., & Birch, G. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r03 · Cited by 907
Toward Brain-Computer Interfacing
(2007) · The MIT Press eBooks · doi:10.7551/mitpress/7493.001.0001 · Cited by 785
Skinput: appropriating the body as an input surface
Harrison, C., Tan, D., & Morris, D. (2010) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/1753326.1753394 · Cited by 694
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
EMG and EOG artifacts in brain computer interface systems: A survey
Fatourechi, M., Bashashati, A., Ward, R. K., & Birch, G. E. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.10.019 · Cited by 638
Chang, C.-Y., Hsu, S.-H., Pion-Tonachini, L., & Jung, T.-P. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2930186 · Cited by 544
A Brain Controlled Wheelchair to Navigate in Familiar Environments
Rebsamen, B., Guan, C., Zhang, H., Wang, C., Teo, C., Ang, M. H., & Burdet, E. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2049862 · Cited by 405
The wadsworth BCI research and development program: at home with BCI
Vaughan, T. M., McFarland, D. J., Schalk, G., Sarnacki, W. A., Krusienski, D. J., Sellers, E. W., & Wolpaw, J. R. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875577 · Cited by 334
Self-citationLotte, F. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2404941 · Cited by 327
“, [2] and [3].”
A high-ITR SSVEP-based BCI speller
Chen, X., Chen, Z., Gao, S., & Gao, X. (2014) · Brain-Computer Interfaces · doi:10.1080/2326263x.2014.944469 · Cited by 301
A Comprehensive Survey of Brain Interface Technology Designs
Mason, S. G., Bashashati, A., Fatourechi, M., Navarro, K. F., & Birch, G. E. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9170-0 · Cited by 299
Brain–Computer Interfaces: A Gentle Introduction
Graimann, B., Allison, B., & Pfurtscheller, G. (2009) · The Frontiers Collection · doi:10.1007/978-3-642-02091-9_1 · Cited by 298
Self-citationAn EEG-Based BCI System for 2-D Cursor Control by Combining Mu/Beta Rhythm and P300 Potential
Li, Y., Long, J., Yu, T., Yu, Z., Wang, C., Zhang, H., & Guan, C. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2055564 · Cited by 298
Development of an SSVEP-based BCI spelling system adopting a QWERTY-style LED keyboard
Hwang, H.-J., Lim, J.-H., Jung, Y.-J., Choi, H., Lee, S. W., & Im, C.-H. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.04.011 · Cited by 251
“…have been developed in order to improve people’s quality of lives, e.g., mental typing of a keyboard (Sellers et al., 2010), controlling of a mouse cursor (Fabiani et al., 2004), navigating of a web browser (Mugler et al., 2010), operating of a wheelchair (Rebsamen et al., 2010), and so on.”
Neural Interface Technology for Rehabilitation: Exploiting and Promoting Neuroplasticity
Wang, W., Collinger, J. L., Perez, M. A., Tyler-Kabara, E. C., Cohen, L. G., Birbaumer, N., Brose, S. W., Schwartz, A. B., Boninger, M. L., & Weber, D. J. (2010) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/j.pmr.2009.07.003 · Cited by 213
A Direct Brain-to-Brain Interface in Humans
Rao, R. P. N., Stocco, A., Bryan, M., Sarma, D., Youngquist, T. M., Wu, J., & Prat, C. S. (2014) · PLoS ONE · doi:10.1371/journal.pone.0111332 · Cited by 210
Neurotechnologies for Human Cognitive Augmentation: Current State of the Art and Future Prospects
Cinel, C., Valeriani, D., & Poli, R. (2019) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2019.00013 · Cited by 178
“Communication BCI systems based on the recording technologies presented in section 2 have typically been used to detect specific (intentionally and unintentionally induced) patterns of brain activity, and translate them into commands for devices or into communication acts (Wolpaw et al., 1991, 2002; Pfurtscheller et a…”
BackgroundMethodCritical issues in state-of-the-art brain–computer interface signal processing
Krusienski, D. J., Grosse-Wentrup, M., Galán, F., Coyle, D., Miller, K. J., Forney, E., & Anderson, C. W. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025002 · Cited by 168
“To account for short-term biasness, debiasing the classifier output, in its simplest form, can be performed in an unsupervised manner by removing the mean calculated from a window of recent classifier outputs from the instantaneous value of the classifier [58], referred to as normalization in [19] where the standard d…”
Distributed cortical adaptation during learning of a brain–computer interface task
Wander, J. D., Blakely, T., Miller, K. J., Weaver, K. E., Johnson, L. A., Olson, J. D., Fetz, E. E., Rao, R. P. N., & Ojemann, J. G. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1221127110 · Cited by 157
Simistira Liwicki, F., Gupta, V., Saini, R., De, K., Abid, N., Rakesh, S., Wellington, S., Wilson, H., Liwicki, M., & Eriksson, J. (2023) · Scientific Data · doi:10.1038/s41597-023-02286-w · Cited by 28
Afergan, D., Shibata, T., Hincks, S. W., Peck, E. M., Yuksel, B. F., Chang, R., & Jacob, R. J. K. (2014) · Proceedings of the 27th annual ACM symposium on User interface software and technology · doi:10.1145/2642918.2647414 · Cited by 19
Metadata
- Authors
- Fabiani, G. E., McFarland, D. J., Wolpaw, J. R., & Pfurtscheller, G.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2004-09
- Volume
- 12
- Issue
- 3
- Pages
- 331-338
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2113019943
- Cited by
- 292
- References
- 26
- FWCI
- 5.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.