The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Evaluation of Artifact Subspace Reconstruction for Automatic Artifact Components Removal in Multi-Channel EEG Recordings
Abstract
OBJECTIVE: Artifact subspace reconstruction (ASR) is an automatic, online-capable, component-based method that can effectively remove transient or large-amplitude artifacts contaminating electroencephalographic (EEG) data. However, the effectiveness of ASR and the optimal choice of its parameter have not been systematically evaluated and reported, especially on actual EEG data. METHODS: This paper systematically evaluates ASR on 20 EEG recordings taken during simulated driving experiments. Independent component analysis (ICA) and an independent component classifier are applied to separate artifacts from brain signals to quantitatively assess the effectiveness of the ASR. RESULTS: ASR removes more eye and muscle components than brain components. Even though some eye and muscle components retain after ASR cleaning, the power of their temporal activities is reduced. Study results also showed that ASR cleaning improved the quality of a subsequent ICA decomposition. CONCLUSIONS: Empirical results show that the optimal ASR parameter is between 20 and 30, balancing between removing non-brain signals and retaining brain activities. SIGNIFICANCE: With an appropriate choice of parameter, ASR can be a powerful and automatic artifact removal approach for offline data analysis or online real-time EEG applications such as clinical monitoring and brain-computer interfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371
The Hungarian method for the assignment problem
Kuhn, H. W. (1955) · Naval Research Logistics Quarterly · doi:10.1002/nav.3800020109 · Cited by 13,120
Oostenveld, R., Fries, P., Maris, E., & Schoffelen, J.-M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/156869 · Cited by 10,323
The ten-twenty electrode system of the international federation
Jasper, H. H. (1958) · Electroencephalography and Clinical Neurophysiology · Cited by 6,567
Removing electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334
Self-citationICLabel: An automated electroencephalographic independent component classifier, dataset, and website
Pion-Tonachini, L., Kreutz-Delgado, K., & Makeig, S. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.026 · Cited by 2,267
Self-citationLee, T.-W., Girolami, M., & Sejnowski, T. J. (1999) · Neural Computation · doi:10.1162/089976699300016719 · Cited by 1,967
EEG artifact removal—state-of-the-art and guidelines
Urigüen, J. A., & Garcia-Zapirain, B. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/031001 · Cited by 963
Independent EEG Sources Are Dipolar
Delorme, A., Palmer, J., Onton, J., Oostenveld, R., & Makeig, S. (2012) · PLoS ONE · doi:10.1371/journal.pone.0030135 · Cited by 810
Real-time neuroimaging and cognitive monitoring using wearable dry EEG
Mullen, T. R., Kothe, C. A. E., Chi, Y. M., Ojeda, A., Kerth, T., Makeig, S., Jung, T.-P., & Cauwenberghs, G. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2481482 · Cited by 795
Self-citation
Cited by
Klug, M., & Gramann, K. (2021) · European Journal of Neuroscience · doi:10.1111/ejn.14992 · Cited by 268
Chuang, C.-H., Chang, K.-Y., Huang, C.-S., & Jung, T.-P. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119586 · Cited by 88
Self-citationBilleci, L., Callara, A. L., Guiducci, L., Prosperi, M., Morales, M. A., Calderoni, S., Muratori, F., & Santocchi, E. (2023) · Autism · doi:10.1177/13623613221082710 · Cited by 69
A data augmentation scheme for geometric deep learning in personalized brain–computer interfaces.
Kalaganis, F. P., Laskaris, N. A., Chatzilari, E., Nikolopoulos, S., & Kompatsiaris, I. (2020) · IEEE Access · doi:10.1109/access.2020.3021580 · Cited by 26
The effect of alpha neurofeedback training on cognitive performance in healthy adults
Nawaz, R., Nisar, H., Yap, V. V., & Tsai, C.-Y. (2022) · Mathematics · doi:10.3390/math10071095 · Cited by 25
“After that, an automatic method known as artifact subspace reconstruction (ASR) is used to reconstruct the artifacts portion of the data with clean data [44].”
Metadata
- Authors
- Chang, C.-Y., Hsu, S.-H., Pion-Tonachini, L., & Jung, T.-P.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2020-04
- Volume
- 67
- Issue
- 4
- Pages
- 1114-1121
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2963881755
- Cited by
- 544
- References
- 40
- FWCI
- 25.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of Artifact Subspace Reconstruction for Automatic Artifact Components Removal in Multi-Channel EEG Recordings. https://app.cochat.ai/papers/10.1109/tbme.2019.2930186
- The paper
- Chang, C.-Y., Hsu, S.-H., Pion-Tonachini, L., & Jung, T.-P. (2020). Evaluation of Artifact Subspace Reconstruction for Automatic Artifact Components Removal in Multi-Channel EEG Recordings. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2019.2930186
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.