CoChat

Investigating the stationarity of paediatric aspiration signals

Chau, T., Chau, D., Casas, M., Berall, G., Kenny, D.J. · 2005 · IEEE Transactions on Neural Systems and Rehabilitation Engineering
Cited by 64

The DOI matches its Crossref record.

Abstract

An aspiration signal is the time-varying anterior-posterior acceleration measured infero-anterior to the thyroid notch when foreign material enters the airway during inspiration. The hypothesis of weak stationarity is tested on aspiration signals by the reverse arrangements test. Results indicate that aspiration signals cannot be uniformly regarded as weakly stationary. Forty-five percent of the examined signals violated the stationarity hypothesis. For these signals, time-varying variance and spectral density structure are identified as major sources of nonstationarity. Stationarity test results generally corroborate qualitative clinical descriptions of aspiration. However, stationarity analysis indicates that aspiration signals are highly heterogenous, a finding which poses significant challenges to the automatic detection of aspirations by accelerometry.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tnsre.2004.841384

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 48

  1. bouguerra, 1996, spectral analysis of swallowing sounds, Gastroenterology, 110, 638a
  2. duchene, 1993, surface electromyogram during voluntary contractions: processing tools and relation to physiological events, Critical Review in Biomedical Engineering, 21, 313
  3. 10.1103/PhysRevE.58.5153 · DOI
  4. 10.1016/S0378-4371(99)00081-3 · doi:10.1016/s0378-4371(99)00081-3
  5. gibbons, 1997, Nonparametric Methods for Quantitative Analysis
  6. chatfield, 1996, The Analysis of Time Series An Introduction
  7. kendall, 1961, The Advanced Theory of Statistics, 2
  8. 10.1175/1520-0469(1994)051<1682:ADATTS>2.0.CO;2 · doi:10.1175/1520-0469(1994)051<1682:adatts>2.0.co;2
  9. 10.1111/1467-9892.00200 · doi:10.1111/1467-9892.00200
  10. 10.1103/PhysRevLett.78.843 · DOI · Paper page
  11. logemann, 1997, Evaluation and Treatment of Swallowing Disorders
  12. 10.1007/PL00009548 · DOI
  13. jelm, 1994, treatment of feeding and swallowing disorders in children: an overview, Clinical Management of Dysphagia in Adults and Children, 185
  14. 10.1007/PL00009544 · DOI · Paper page
  15. 10.1161/01.STR.28.9.1773 · DOI
  16. sorin, 1987, electro-glottographic examination of swallowing, Arch Phys Med Rehab, 68, 232
  17. 10.1007/PL00009524 · DOI
  18. reddy, 1994, toward classification of dysphagic patients using biomechanical measurements, J Rehab Res Develop, 31, 335
  19. 10.1016/S0169-2607(00)00099-7 · DOI
  20. 10.1016/S1350-4533(00)00047-3 · DOI
  21. 10.1109/10.52346 · DOI · Paper page
  22. schreiber, 1999, interdisciplinary application of nonlinear time series methods, Phys Rep, 308, 2, 10.1016/S0370-1573(98)00035-0 · DOI · Paper page
  23. 10.1007/BF01383388 · doi:10.1007/bf01383388
  24. papoulis, 1991, Probability random variables and stochastic processes
  25. 10.1016/S0003-9993(98)90200-3 · DOI · Paper page
  26. sheppard, 1997, pediatric dysphagia and related medical, behavioral, and developmental issues, Dysphagia A Continuum of Care, 55
  27. box, 1970, Time Series Analysis Forecasting and Control
  28. 10.1007/PL00009579 · DOI
  29. 10.1113/jphysiol.1995.sp020584 · DOI · Paper page
  30. prontnicki, 1995, presentation: symptomatology and etiology of dysphagia, Dysphagia and the Child with Developmental Disabilities, 1
  31. 10.1136/jnnp.63.4.456 · DOI
  32. rubin, 2000, The Swallowing Manual
  33. 10.1007/s004550000047 · doi:10.1007/s004550000047
  34. shumway, 2000, Time Series Applications and Its Application
  35. 10.1016/0141-5425(91)90018-3 · DOI
  36. 10.1007/978-1-4614-7572-9 · DOI · Paper page
  37. 10.1016/S1050-6411(96)00024-7 · DOI
  38. stevenson, 1991, the development of normal feeding and swallowing, Pediat Clin North Amer, 38, 1439, 10.1016/S0031-3955(16)38229-3 · DOI · Paper page
  39. 10.1016/S0002-9343(01)00860-9 · DOI · Paper page
  40. firmin, 1997, “non-invasive monitoring of reflexive swallowing”, Speech Hearing Lang Electron J, 10
  41. 10.1137/1.9781611970104 · DOI · Paper page
  42. bendat, 2000, Random Data Analysis and Measurement Procedures
  43. mallat, 1999, A Wavelet Tour of Signal Processing
  44. 10.1016/0013-4694(95)00198-8 · DOI
  45. 10.1016/S0025-5564(98)10088-3 · DOI
  46. tong, 1990, Non-Linear Time Series A Dynamical Systems Approach, 10.1093/oso/9780198522249.001.0001 · DOI · Paper page
  47. shevlyalpv, 2002, Robustness in Data Analysis
  48. 10.1088/0967-3334/23/1/201 · DOI · Paper page

Cited by

See all 64

Metadata

Authors
Chau, T., Chau, D., Casas, M., Berall, G., & Kenny, D. J.
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2005-03
Volume
13
Issue
1
Pages
99-105
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2153915745
Cited by
64
References
0
FWCI
2.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Investigating the stationarity of paediatric aspiration signals. https://app.cochat.ai/papers/10.1109/tnsre.2004.841384
The paper
Chau, T., Chau, D., Casas, M., Berall, G., & Kenny, D. J. (2005). Investigating the stationarity of paediatric aspiration signals. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2004.841384

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.