A rehabilitation robot with force-position hybrid fuzzy controller: hybrid fuzzy control of rehabilitation robot
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
The goal of this study was to design a robot system for assisting in the rehabilitation of patients with neuromuscular disorders by performing various facilitation movements. The robot should be able to guide patient's wrist to move along planned linear or circular trajectories. A hybrid position/force controller incorporating fuzzy logic was developed to constrain the movement in the desired direction and to maintain a constant force along the moving direction. The controller was stable in the application range of movements and forces. Offline analyses of data were used to quantitatively assess the progress of rehabilitation. The results show that the robot could guide the upper limbs of subjects in linear and circular movements under predefined external force levels and apply a desired force along the tangential direction of the movements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fuzzy logic in control systems: fuzzy logic controller. I
Lee, C. C. (1990) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/21.52551 · Cited by 5,616
Hybrid Position/Force Control of Manipulators
Raibert, M. H., & Craig, J. J. (1981) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3139652 · Cited by 3,015 · cited 2×
“For the overall control scheme, we adopted the hybrid position/force control [6], i.”
BackgroundMethodAdaptive Fuzzy Systems and Control: Design and Stability Analysis
Wang, L. (1994) · Medical Entomology and Zoology · Cited by 2,736
Robot-aided neurorehabilitation
Krebs, H. I., Hogan, N., Aisen, M. L., & Volpe, B. T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.662623 · Cited by 1,425 · cited 4×
“The basic construction principle of our robot and MIT-MANUS is similar.”
BackgroundMethodInfluentialFuzzy logic in control systems: fuzzy logic controller. II
Lee, C. C. (1990) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/21.52552 · Cited by 1,315
Lum, P. S., Burgar, C. G., Shor, P. C., Majmundar, M., & Van der Loos, M. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.33101 · Cited by 1,159 · cited 5×
“An alternative approach was adopted in the active-constrained mode of mirror image movement enabler (MIME) system [8], [9].”
MethodInfluentialDevelopment of robots for rehabilitation therapy: the Palo Alto VA/Stanford experience.
Burgar, C. G., Lum, P. S., Shor, P. C., & der Loos, H. F. M. V. (2000) · PubMed · Cited by 800
Foundations of robotics: analysis and control
(1991) · Choice Reviews Online · doi:10.5860/choice.28-5104 · Cited by 535
Application of rubber artificial muscle manipulator as a rehabilitation robot
Noritsugu, T., & Tanaka, T. (1997) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/3516.653050 · Cited by 243
Analysis and Design of a Direct-Drive Arm With a Five-Bar-Link Parallel Drive Mechanism
Asada, H., & Youcef-Toumi, K. (1984) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3149676 · Cited by 189 · cited 1×
“mechanism [20] for constructing the robot.”
Applying fuzzy logic to control cycling movement induced by functional electrical stimulation
Chen, J. J., Yu, N., Huang, D.-G., Ann, B.-T., & Chang, G.-C. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.593285 · Cited by 127 · cited 1×
“In the past, we successfully applied fuzzy control to the above-knee prostheses and cycling exercise by functional electrical stimulation [17]‐[ 19 ].”
MethodRobotic assistance of an active upper limb exercise in neurologically impaired patients
Cozens, J. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.769416 · Cited by 106 · cited 1×
“Cozens [ 4 ], using a single axis robot and torque control mode, applied resistive or assistive torque to the elbow for rehabilitation of patients with spasticity and weakness.”
MethodExperimental determination of dynamic parameters of robotic arms
Lu, Z., Shimoga, K. B., & Goldenberg, A. A. (1993) · Journal of Robotic Systems · doi:10.1002/rob.4620100803 · Cited by 42 · cited 1×
“where and were torques to be compensated, was a constant for viscous friction term and was a static for Coulomb friction torque [21]. and were determined empirically [ 22 ].”
BackgroundJu, M., Lin, C. K., Chen, J. R., Cheng, H., & Lin, C.-J. (2002) · Clinical Biomechanics · doi:10.1016/s0268-0033(02)00131-6 · Cited by 35
Self-citation
Cited by
A survey on robotic devices for upper limb rehabilitation
Maciejasz, P., Eschweiler, J., Gerlach-Hahn, K., Jansen-Troy, A., & Leonhardt, S. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-3 · Cited by 1,210
Review of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, L., & Reinkensmeyer, D. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-20 · Cited by 1,182
Recent development of mechanisms and control strategies for robot-assisted lower limb rehabilitation
Meng, W., Liu, Q., Zhou, Z., Ai, Q., Sheng, B., & Xie, S. (. (2015) · Mechatronics · doi:10.1016/j.mechatronics.2015.04.005 · Cited by 464
Metadata
- Authors
- Ju, M.-S., Lin, C.-C. K., Lin, D.-H., Hwang, I.-S., & Chen, S.-M.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2005-09
- Volume
- 13
- Issue
- 3
- Pages
- 349-358
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2125213782
- Cited by
- 179
- References
- 14
- FWCI
- 1.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.