Ambulatory measurement of ground reaction forces
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
The measurement of ground reaction forces is important in the biomechanical analysis of gait and other motor activities. Many applications require full ambulatory measurement of these forces, but this is not supported by current measurement systems. We propose the use of two six-degrees-of-freedom force and moment sensors under each shoe, which enables the ambulatory measurement of ground reaction forces and centers of pressure (CoP). The feasibility of this method is illustrated by experimental results in a healthy subject, using a force plate as a reference. The ground reaction forces and CoP recordings show good correspondence when they are evaluated for forces above 40 N and when it is simply assumed that the sensors are flat on the ground when they are loaded. The root mean square (rms) difference of the magnitude of the ground reaction force over 12 gait trials was 15 +/- 2 N, corresponding to 1.9 +/- 0.3% of the maximum ground reaction force magnitude. The rms difference of the horizontal component of the ground reaction force was 3 +/- 2 N, corresponding to 0.4 +/- 0.2% of the maximum ground reaction force magnitude and to 2 +/- 1% of the maximum of the horizontal component of the ground reaction force. The rms distance between both CoP recordings is 2.9 +/- 0.4 mm, corresponding to 1.1 +/- 0.2% of the length of the shoe, when the trajectories are optimally aligned.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Biomechanics and Motor Control of Human Movement
Winter, D. A. (2009) · Wiley eBooks · doi:10.1002/9780470549148 · Cited by 6,066 · cited 2×
“THE ACCEPTED measurement system for biomechanical assessment of human ambulation today is a laboratorybound system with optical measurement of movement and force plate measurement of ground reaction forces (GRF) [1].”
MethodActive control of lateral balance in human walking
Bauby, C. E., & Kuo, A. D. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00101-9 · Cited by 851 · cited 1×
“In order to balance the body during gait, each step needs to be different [14].”
BackgroundInclination measurement of human movement using a 3-D accelerometer with autocalibration
Luinge, H. J., & Veltink, P. H. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.822759 · Cited by 307 · cited 2×
“movement analysis methods reported in recent years [6]–[9], [13], this may allow for full biomechanical analysis of movement tasks at any place and outside of a movement analysis laboratory.”
BackgroundSelf-citationInertial sensing of human movement
Luinge, H. J. (2002) · University of Twente Research Information · Cited by 194
Bachmann, E. R. (2000) · Calhoun: The Naval Postgraduate School Institutional Archive (Naval Postgraduate School) · Cited by 178
An inverse dynamics model for the analysis, reconstruction and prediction of bipedal walking
Koopman, B., Grootenboer, H. J., & de Jongh, H. J. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00185-7 · Cited by 178 · cited 1×
“From the body movements and ground reaction forces measured with these laboratory systems, joint moments can be estimated by inverse dynamics methods [1], [2].”
MethodReal-time gait assessment utilizing a new way of accelerometry
Willemsen, A., van Alste, J. A., & Boom, H. B. K. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90033-y · Cited by 130 · cited 2×
“movement analysis methods reported in recent years [6]–[9], [13], this may allow for full biomechanical analysis of movement tasks at any place and outside of a movement analysis laboratory.”
BackgroundBussmann, H. B., Reuvekamp, P. J., Veltink, P. H., Martens, W. L., & Stam, H. J. (1998) · Physical Therapy · doi:10.1093/ptj/78.9.989 · Cited by 120
Self-citationVeltink, P. H., Slycke, P., Hemssems, J., Buschman, R., Bultstra, G., & Hermens, H. (2003) · Medical Engineering & Physics · doi:10.1016/s1350-4533(02)00041-3 · Cited by 99 · cited 1×
“movement analysis methods reported in recent years [6]–[9], [13], this may allow for full biomechanical analysis of movement tasks at any place and outside of a movement analysis laboratory.”
BackgroundSelf-citationSurface electromyography analysis for variable gait
Roetenberg, D., Buurke, J. H., Veltink, P. H., Forner‐Cordero, A., & Hermens, H. J. (2003) · Gait & Posture · doi:10.1016/s0966-6362(03)00005-5 · Cited by 73 · cited 1×
“The analysis of the variability of gait, and thus the measurement of all steps, is even more important in patients with neuromuscular disorders like stroke [ 15 ].”
BackgroundSelf-citationBussmann, J. B., Veltink, P. H., Koelma, F., van Lummel, R. C., & Stam, H. J. (1995) · University of Twente Research Information · Cited by 68
Self-citationInertial sensing in ambulatory back load estimation
Baten, C. T. M., Oosterhoff, P., Kingma, I., Veltink, P. H., & Hermens, H. J. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1996.651834 · Cited by 18 · cited 1×
“Ambulatory assessment is, however, required in many applications of human movement analysis, including the evaluation of the impact of rehabilitation treatments in daily life [3], [4] and the ergonomic evaluation of working tasks and environments [ 5 ].”
BackgroundSelf-citation
Cited by
Gait Analysis Using Wearable Sensors
Tao, W., Liu, T., Zheng, R., & Feng, H. (2012) · Sensors · doi:10.3390/s120202255 · Cited by 1,165
Activity identification using body-mounted sensors—a review of classification techniques
Preece, S. J., Goulermas, J. Y., Kenney, L. P. J., Howard, D., Meijer, K., & Crompton, R. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/4/r01 · Cited by 600
Toward Pervasive Gait Analysis With Wearable Sensors: A Systematic Review
Chen, S., Lach, J., Lo, B., & Yang, G.-Z. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2608720 · Cited by 443
Heart rate measurement based on a time-lapse image.
Takano, C., & Ohta, Y. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.09.006 · Cited by 345
Ambulatory Position and Orientation Tracking Fusing Magnetic and Inertial Sensing
Roetenberg, D., Slycke, P. J., & Veltink, P. H. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889184 · Cited by 334
Self-citation
Metadata
- Authors
- Veltink, P. H., Liedtke, C., Droog, E., & van der Kooij, H.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2005-09
- Volume
- 13
- Issue
- 3
- Pages
- 423-427
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2800390133
- Cited by
- 161
- References
- 13
- FWCI
- 3.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.