Robotic techniques for upper limb evaluation and rehabilitation of stroke patients
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
This paper presents two robot devices for use in the rehabilitation of upper limb movements and reports the quantitative parameters obtained to characterize the rate of improvement, thus allowing a precise monitoring of patient's recovery. A one degree of freedom (DoF) wrist manipulator and a two-DoF elbow-shoulder manipulator were designed using an admittance control strategy; if the patient could not move the handle, the devices completed the motor task. Two groups of chronic post-stroke patients (G1 n = 7, and G2 n = 9) were enrolled in a three week rehabilitation program including standard physical therapy (45 min daily) plus treatment by means of robot devices, respectively, for wrist and elbow-shoulder movements (40 min, twice daily). Both groups were evaluated by means of standard clinical assessment scales and a new robot measured evaluation metrics that included an active movement index quantifying the patient's ability to execute the assigned motor task without robot assistance, the mean velocity, and a movement accuracy index measuring the distance of the executed path from the theoretic one. After treatment, both groups improved their motor deficit and disability. In G1, there was a significant change in the clinical scale values (p < 0.05) and range of motion wrist extension (p < 0.02). G2 showed a significant change in clinical scales (p < 0.01), in strength (p < 0.05) and in the robot measured parameters (p < 0.01). The relationship between robot measured parameters and the clinical assessment scales showed a moderate and significant correlation (r > 0.53 p < 0.03). Our findings suggest that robot-aided neurorehabilitation may improve the motor outcome and disability of chronic post-stroke patients. The new robot measured parameters may provide useful information about the course of treatment and its effectiveness at discharge.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The post-stroke hemiplegic patient. 1. a method for evaluation of physical performance
Fugl-Meyer, A., Jääskö, L., Leyman, I., Olsson, S., & Steglind, S. (1975) · Journal of Rehabilitation Medicine · doi:10.2340/1650197771331 · Cited by 5,564
Impedance Control: An Approach to Manipulation: Part I—Theory
Hogan, N. (1985) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3140702 · Cited by 3,673
Robot-aided neurorehabilitation
Krebs, H. I., Hogan, N., Aisen, M. L., & Volpe, B. T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.662623 · Cited by 1,425
Lum, P. S., Burgar, C. G., Shor, P. C., Majmundar, M., & Van der Loos, M. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.33101 · Cited by 1,159 · cited 1×
“In particular, the MIT-Manus [13], [15], [17], [19], [20] and the mirror-image motion enabler (MIME) robots [16], [18], which were developed for unrestricted unilateral or bilateral shoulder and elbow movement, show that the recovery can be improved through additional therapy aided by robot technology.”
BackgroundTHE RESTORATION OF MOTOR FUNCTION FOLLOWING HEMIPLEGIA IN MAN
TWITCHELL, T. E. (1951) · Brain · doi:10.1093/brain/74.4.443 · Cited by 940
Intensity of leg and arm training after primary middle-cerebral-artery stroke: a randomised trial
Kwakkel, G., Wagenaar, R. C., Twisk, J. W., Lankhorst, G. J., & Koetsier, J. C. (1999) · The Lancet · doi:10.1016/s0140-6736(98)09477-x · Cited by 938
Development of robots for rehabilitation therapy: the Palo Alto VA/Stanford experience.
Burgar, C. G., Lum, P. S., Shor, P. C., & der Loos, H. F. M. V. (2000) · PubMed · Cited by 800
A novel approach to stroke rehabilitation: Robot-aided sensorimotor stimulation
Volpe, B. T., Krebs, H. I., Hogan, N., Edelstein, L., Diels, C., & Aisen, M. (2000) · Neurology · doi:10.1212/wnl.54.10.1938 · Cited by 582
Reinkensmeyer, D. J., Kahn, L. E., Averbuch, M., McKenna-Cole, A. N., Schmit, B. D., & Rymer, W. Z. (2000) · PubMed · Cited by 558
Hesse, S., Schulte-Tigges, G., Konrad, M., Bardeleben, A., & Werner, C. (2003) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(02)04954-7 · Cited by 489
Cited by
Effects of Robot-Assisted Therapy on Upper Limb Recovery After Stroke: A Systematic Review
Kwakkel, G., Kollen, B. J., & Krebs, H. I. (2008) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968307305457 · Cited by 1,503
Review of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, L., & Reinkensmeyer, D. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-20 · Cited by 1,182
Optimizing Compliant, Model-Based Robotic Assistance to Promote Neurorehabilitation
Wolbrecht, E. T., Chan, V., Reinkensmeyer, D. J., & Bobrow, J. E. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.918389 · Cited by 506
Robotic-Assisted Rehabilitation of the Upper Limb After Acute Stroke
Masiero, S., Celia, A., Rosati, G., & Armani, M. (2007) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2006.10.032 · Cited by 409
Admittance control for physical human–robot interaction
Keemink, A. Q., van der Kooij, H., & Stienen, A. H. (2018) · The International Journal of Robotics Research · doi:10.1177/0278364918768950 · Cited by 395
Design strategies to improve patient motivation during robot-aided rehabilitation
Colombo, R., Pisano, F., Mazzone, A., Delconte, C., Micera, S., Carrozza, M. C., Dario, P., & Minuco, G. (2007) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-4-3 · Cited by 385
Self-citationAn EMG-Controlled Robotic Hand Exoskeleton for Bilateral Rehabilitation
Leonardis, D., Chisari, C., Bergamasco, M., Frisoli, A., Barsotti, M., Loconsole, C., Solazzi, M., Troncossi, M., Mazzotti, C., Castelli, V. P., et al. (2015) · IEEE Transactions on Haptics · doi:10.1109/toh.2015.2417570 · Cited by 339
Poststroke Upper Extremity Rehabilitation: A Review of Robotic Systems and Clinical Results
Brewer, B. R., McDowell, S. K., & Worthen-Chaudhari, L. C. (2007) · Topics in Stroke Rehabilitation · doi:10.1310/tsr1406-22 · Cited by 301
Bosecker, C., Dipietro, L., Volpe, B., & Igo Krebs, H. (2010) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968309343214 · Cited by 300
Assessment of movement quality in robot- assisted upper limb rehabilitation after stroke: a review
Nordin, N., Xie, S., & Wünsche, B. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-137 · Cited by 271
Chiri, A., Vitiello, N., Giovacchini, F., Roccella, S., Vecchi, F., & Carrozza, M. C. (2012) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2011.2144614 · Cited by 254
Self-citationAdvances in upper limb stroke rehabilitation: a technology push
Loureiro, R. C. V., Harwin, W. S., Nagai, K., & Johnson, M. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0797-0 · Cited by 252
Emken, J. L., Benitez, R., & Reinkensmeyer, D. J. (2007) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-4-8 · Cited by 199
de los Reyes-Guzmán, A., Dimbwadyo-Terrer, I., Trincado-Alonso, F., Monasterio-Huelin, F., Torricelli, D., & Gil-Agudo, A. (2014) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2014.06.013 · Cited by 194
The Present and Future of Robotic Technology in Rehabilitation
Laut, J., Porfiri, M., & Raghavan, P. (2016) · Current Physical Medicine and Rehabilitation Reports · doi:10.1007/s40141-016-0139-0 · Cited by 179
“End-effector devices for the treatment of the upper limb interface with the user through a manipulandum that is held in the hand [20]; end-effector devices for gait training interface at the foot or feet [21].”
Assessing Mechanisms of Recovery During Robot-Aided Neurorehabilitation of the Upper Limb
Colombo, R., Pisano, F., Micera, S., Mazzone, A., Delconte, C., Carrozza, M. C., Dario, P., & Minuco, G. (2008) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968307303401 · Cited by 167
“Three control strategies were implemented to allow the possibility of 1) completely voluntary movements, 2) shared control of the movements, that is, the system helps the patient to carry out the part of the task he or she is not able to do autonomously, and 3) completely passive movements.(28) Seamless transition amo…”
MethodResultSelf-citationLiu, J., Cramer, S. C., & Reinkensmeyer, D. (2006) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-3-20 · Cited by 119
Atashzar, S. F., Polushin, I. G., & Patel, R. V. (2017) · IEEE Transactions on Robotics · doi:10.1109/tro.2016.2623336 · Cited by 57
“There are significant advantages with the use of haptics-enabled robotic rehabilitation systems, such as accelerating recovery of disabled patients [2], [4] and helping therapists in quantifying the severity of movement disorders [5], [6].”
BackgroundMethodInfluentialOn the Use of Divergent Force Fields in Robot-Mediated Neurorehabilitation
Cesqui, B., Aliboni, S., Mazzoleni, S., Carrozza, M. C., Posteraro, F., & Micera, S. (2008) · 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics · doi:10.1109/biorob.2008.4762927 · Cited by 34
“It is obtained normalizing the effective length path with the ideal one (Lt)[4, 31]:”
BackgroundSelf-citation
Metadata
- Authors
- Colombo, R., Pisano, F., Micera, S., Mazzone, A., Delconte, C., Carrozza, M. C., Dario, P., & Minuco, G.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2005-09
- Volume
- 13
- Issue
- 3
- Pages
- 311-324
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2110171919
- Cited by
- 399
- References
- 30
- FWCI
- 12.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.