Kinematic Design to Improve Ergonomics in Human Machine Interaction
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
This paper introduces a novel kinematic design paradigm for ergonomic human machine interaction. Goals for optimal design are formulated generically and applied to the mechanical design of an upper-arm exoskeleton. A nine degree-of-freedom (DOF) model of the human arm kinematics is presented and used to develop, test, and optimize the kinematic structure of an human arm interfacing exoskeleton. The resulting device can interact with an unprecedented portion of the natural limb workspace, including motions in the shoulder-girdle, shoulder, elbow, and the wrist. The exoskeleton does not require alignment to the human joint axes, yet is able to actuate each DOF of our redundant limb unambiguously and without reaching into singularities. The device is comfortable to wear and does not create residual forces if misalignments exist. Implemented in a rehabilitation robot, the design features of the exoskeleton could enable longer lasting training sessions, training of fully natural tasks such as activities of daily living and shorter dress-on and dress-off times. Results from inter-subject experiments with a prototype are presented, that verify usability over the entire workspace of the human arm, including shoulder and shoulder girdle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wu, G., van der Helm, F. C. T., (DirkJan) Veeger, H. E. J., Makhsous, M., Van Roy, P., Anglin, C., Nagels, J., Karduna, A. R., McQuade, K., Wang, X., et al. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.042 · Cited by 4,558
Self-citationA Kinematic Notation for Lower-Pair Mechanisms Based on Matrices
Denavit, J., & Hartenberg, R. S. (1955) · Journal of Applied Mechanics · doi:10.1115/1.4011045 · Cited by 4,551
Impedance Control: An Approach to Manipulation: Part I—Theory
Hogan, N. (1985) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3140702 · Cited by 3,673
Treadmill training of paraplegic patients using a robotic orthosis.
Colombo, G., Joerg, M., Schreier, R., & Dietz, V. (2000) · PubMed · Cited by 1,292
Bütefisch, C., Hummelsheim, H., Denzler, P., & Mauritz, K.-H. (1995) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(95)00003-k · Cited by 840
Development of robots for rehabilitation therapy: the Palo Alto VA/Stanford experience.
Burgar, C. G., Lum, P. S., Shor, P. C., & der Loos, H. F. M. V. (2000) · PubMed · Cited by 800
Dewald, J. P. A., Pope, P. S., Given, J. D., Buchanan, T. S., & Rymer, W. Z. (1995) · Brain · doi:10.1093/brain/118.2.495 · Cited by 711
Reinkensmeyer, D. J., Kahn, L. E., Averbuch, M., McKenna-Cole, A. N., Schmit, B. D., & Rymer, W. Z. (2000) · PubMed · Cited by 558
Gray, M. I. (1985) · Journal of Occupational Accidents · doi:10.1016/0376-6349(85)90024-0 · Cited by 525
Increasing productivity and quality of care: robot-aided neuro-rehabilitation.
Krebs, H. I., Volpe, B. T., Aisen, M. L., & Hogan, N. (2000) · PubMed · Cited by 441
Cited by
A survey on robotic devices for upper limb rehabilitation
Maciejasz, P., Eschweiler, J., Gerlach-Hahn, K., Jansen-Troy, A., & Leonhardt, S. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-3 · Cited by 1,210
ARMin III – Arm Therapy Exoskeleton with an Ergonomic Shoulder Actuation
Nef, T., Guidali, M., & Riener, R. (2009) · Applied Bionics and Biomechanics · doi:10.1080/11762320902840179 · Cited by 522
Kim, B., & Deshpande, A. D. (2017) · The International Journal of Robotics Research · doi:10.1177/0278364917706743 · Cited by 309
NEUROExos: a powered elbow exoskeleton for physical rehabilitation
Vitiello, N., Lenzi, T., Roccella, S., De Rossi, S. M. M., Cattin, E., Giovacchini, F., Vecchi, F., & Carrozza, M. C. (2013) · IEEE Transactions on Robotics · doi:10.1109/tro.2012.2211492 · Cited by 272
“The robot should be lightweight and take into account the user's joints range of motion (ROM), anthropometry, and kinematics [32], [34].”
BackgroundConnecting a Human Limb to an Exoskeleton
Jarrasse, N., & Morel, G. (2012) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2178151 · Cited by 263
A light-weight active orthosis for hip movement assistance
Giovacchini, F., Vannetti, F., Fantozzi, M., Cempini, M., Cortese, M., Parri, A., Yan, T., Lefeber, D., & Vitiello, N. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.015 · Cited by 258
Biomechanical and Physiological Evaluation of Multi-Joint Assistance With Soft Exosuits
Ding, Y., Galiana, I., Asbeck, A. T., De Rossi, S. M. M., Bae, J., Santos, T. R. T., de Araujo, V. L., Lee, S., Holt, K. G., & Walsh, C. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2523250 · Cited by 217
“While these are impressive achievements, the rigid nature of existing exoskeletons presents a number of challenges towards the goal of enhancing or restoring locomotion: 1) they may interfere with joint movement due to misalignment between the robot and biological joints and thus cause the wearer to deviate from their…”
BackgroundPassive Back Support Exoskeleton Improves Range of Motion Using Flexible Beams
Näf, M. B., Koopman, A. S., Baltrusch, S., Rodriguez-Guerrero, C., Vanderborght, B., & Lefeber, D. (2018) · Frontiers in Robotics and AI · doi:10.3389/frobt.2018.00072 · Cited by 207
Crea, S., Beckerle, P., De Looze, M., De Pauw, K., Grazi, L., Kermavnar, T., Masood, J., O’Sullivan, L. W., Pacifico, I., Rodriguez-Guerrero, C., et al. (2021) · Wearable Technologies · doi:10.1017/wtc.2021.11 · Cited by 206
“Based on their kinematic structures , rigid exoskeletons can be classified as anthropomorphic or nonanthropomorphic (e.g., end-effector-like) devices (Schiele and van der Helm, 2006; Naf et al., 2018).”
Oscillator-based assistance of cyclical movements: model-based and model-free approaches
Ronsse, R., Lenzi, T., Vitiello, N., Koopman, B., van Asseldonk, E., De Rossi, S. M. M., van den Kieboom, J., van der Kooij, H., Carrozza, M. C., & Ijspeert, A. J. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0816-1 · Cited by 188
“Ergonomics studies [41] provide the main design guidelines for these interfaces, which are particularly critical in the case of wearable robots [7], due to the close interaction with the user.”
BackgroundHuman Movement Training With a Cable Driven ARm EXoskeleton (CAREX)
Mao, Y., Jin, X., Gera Dutta, G., Scholz, J. P., & Agrawal, S. K. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2329018 · Cited by 178
A structured overview of trends and technologies used in dynamic hand orthoses
Bos, R. A., Haarman, C. J. W., Stortelder, T., Nizamis, K., Herder, J. L., Stienen, A. H. A., & Plettenburg, D. H. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0168-z · Cited by 162
“Even tissue damage can occur, where pressure sores, joint dislocations or cartilage damage are among the possibilities depending on the user [102, 103].”
Background
Metadata
- Authors
- Schiele, A., & van der Helm, F. C. T.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2006-12
- Volume
- 14
- Issue
- 4
- Pages
- 456-469
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2134525555
- Cited by
- 386
- References
- 27
- FWCI
- 7.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.