The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Kinematic Design to Improve Ergonomics in Human Machine Interaction
Abstract
This paper introduces a novel kinematic design paradigm for ergonomic human machine interaction. Goals for optimal design are formulated generically and applied to the mechanical design of an upper-arm exoskeleton. A nine degree-of-freedom (DOF) model of the human arm kinematics is presented and used to develop, test, and optimize the kinematic structure of an human arm interfacing exoskeleton. The resulting device can interact with an unprecedented portion of the natural limb workspace, including motions in the shoulder-girdle, shoulder, elbow, and the wrist. The exoskeleton does not require alignment to the human joint axes, yet is able to actuate each DOF of our redundant limb unambiguously and without reaching into singularities. The device is comfortable to wear and does not create residual forces if misalignments exist. Implemented in a rehabilitation robot, the design features of the exoskeleton could enable longer lasting training sessions, training of fully natural tasks such as activities of daily living and shorter dress-on and dress-off times. Results from inter-subject experiments with a prototype are presented, that verify usability over the entire workspace of the human arm, including shoulder and shoulder girdle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wu, G., van der Helm, F. C. T., (DirkJan) Veeger, H. E. J., Makhsous, M., Van Roy, P., Anglin, C., Nagels, J., Karduna, A. R., McQuade, K., Wang, X., et al. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.042 · Cited by 4,558
Self-citationA Kinematic Notation for Lower-Pair Mechanisms Based on Matrices
Denavit, J., & Hartenberg, R. S. (1955) · Journal of Applied Mechanics · doi:10.1115/1.4011045 · Cited by 4,551
Impedance Control: An Approach to Manipulation: Part I—Theory
Hogan, N. (1985) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3140702 · Cited by 3,673
Treadmill training of paraplegic patients using a robotic orthosis.
Colombo, G., Joerg, M., Schreier, R., & Dietz, V. (2000) · PubMed · Cited by 1,114
Bütefisch, C., Hummelsheim, H., Denzler, P., & Mauritz, K.-H. (1995) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(95)00003-k · Cited by 840
Dewald, J. P. A., Pope, P. S., Given, J. D., Buchanan, T. S., & Rymer, W. Z. (1995) · Brain · doi:10.1093/brain/118.2.495 · Cited by 711
Development of robots for rehabilitation therapy: the Palo Alto VA/Stanford experience.
Burgar, C. G., Lum, P. S., Shor, P. C., & der Loos, H. F. M. V. (2000) · PubMed · Cited by 672
Reinkensmeyer, D. J., Kahn, L. E., Averbuch, M., McKenna-Cole, A. N., Schmit, B. D., & Rymer, W. Z. (2000) · PubMed · Cited by 549
Gray, M. I. (1985) · Journal of Occupational Accidents · doi:10.1016/0376-6349(85)90024-0 · Cited by 525
Increasing productivity and quality of care: robot-aided neuro-rehabilitation.
Krebs, H. I., Volpe, B. T., Aisen, M. L., & Hogan, N. (2000) · PubMed · Cited by 441
Robot-aided neurorehabilitation of the upper extremities
Riener, R., Nef, T., & Colombo, G. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345116 · Cited by 407
A mechanized gait trainer for restoration of gait.
Hesse, S., & Uhlenbrock, D. (2000) · PubMed · Cited by 388
Locomotor activity in spinal cord-injured persons
Dietz, V., & Harkema, S. J. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00942.2003 · Cited by 351
Sunderland, A., Tinson, D. J., Bradley, E. L., Fletcher, D., Langton Hewer, R., & Wade, D. T. (1992) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.55.7.530 · Cited by 332
Alterations in muscle activation patterns during robotic-assisted walking
Hidler, J. M., & Wall, A. E. (2005) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2004.09.016 · Cited by 309
Lum, P. S., Burgar, C. G., & Shor, P. C. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.827225 · Cited by 281
Impedance Control:An Approach to Manipulation,Parts I,II,III
Hogan, N. (1985) · Medical Entomology and Zoology · Cited by 254
Tapping into spinal circuits to restore motor function
Barbeau, H., McCrea, D. A., O'Donovan, M. J., Rossignol, S., Grill, W. M., & Lemay, M. A. (1999) · Brain Research Reviews · doi:10.1016/s0165-0173(99)00008-9 · Cited by 212
An arm exoskeleton system for teleoperation and virtual environments applications
Bergamasco, M., Allotta, B., Bosio, L., Ferretti, L., Parrini, G., Prisco, G. M., Salsedo, F., & Sartini, G. (2002) · Proceedings of the 1994 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.1994.351286 · Cited by 196
A mechanized gait trainer for restoring gait in nonambulatory subjects
Hesse, S., Uhlenbrock, D., Werner, C., & Bardeleben, A. (2000) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2000.6280 · Cited by 193
Design of an arm exoskeleton with scapula motion for shoulder rehabilitation
Roderick, S., Liszka, M., & Carignan, C. (2005) · ICAR '05. Proceedings., 12th International Conference on Advanced Robotics, 2005. · doi:10.1109/icar.2005.1507459 · Cited by 178
Veneman, J. F., Ekkelenkamp, R., Kruidhof, R., van der Helm, F. C. T., & van der Kooij, H. (2005) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2005.1501150 · Cited by 136
Therapy impact on functional outcome in a controlled trial of stroke rehabilitation.
Smith, M., GARRAWAY, W. M., SMITH, D. L., & Akhtar, A. (1982) · PubMed · Cited by 116
Spasticity: Mechanisms and Management
Thilmann, A. F., Burke, D. J., & Rymer, W. Z. (1994) · Cited by 88
Driven gait orthosis to do locomotor training of paraplegic patients
Colombo, G., Jorg, M., & Dietz, V. (2002) · Proceedings of the 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (Cat. No.00CH37143) · doi:10.1109/iembs.2000.901556 · Cited by 72
Design of a Robotic Upper Extremity Repetitive Therapy Device
He, J., Koeneman, E. J., Schultz, R. S., Huang, H., Wanberg, J., Herring, D. E., Sugar, T. G., Herman, R. M., & Koeneman, J. B. (2005) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2005.1501060 · Cited by 56
Issues in impedance selection and input devices for multijoint powered orthotics
Lemay, M. A., Hogan, N., & van Dorsten, J. W. A. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.662626 · Cited by 31
Cited by
A survey on robotic devices for upper limb rehabilitation
Maciejasz, P., Eschweiler, J., Gerlach-Hahn, K., Jansen-Troy, A., & Leonhardt, S. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-3 · Cited by 1,210
ARMin III – Arm Therapy Exoskeleton with an Ergonomic Shoulder Actuation
Nef, T., Guidali, M., & Riener, R. (2009) · Applied Bionics and Biomechanics · doi:10.1080/11762320902840179 · Cited by 522
Kim, B., & Deshpande, A. D. (2017) · The International Journal of Robotics Research · doi:10.1177/0278364917706743 · Cited by 309
NEUROExos: a powered elbow exoskeleton for physical rehabilitation
Vitiello, N., Lenzi, T., Roccella, S., De Rossi, S. M. M., Cattin, E., Giovacchini, F., Vecchi, F., & Carrozza, M. C. (2013) · IEEE Transactions on Robotics · doi:10.1109/tro.2012.2211492 · Cited by 272
Connecting a Human Limb to an Exoskeleton
Jarrasse, N., & Morel, G. (2012) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2178151 · Cited by 263
Metadata
- Authors
- Schiele, A., & van der Helm, F. C. T.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2006-12
- Volume
- 14
- Issue
- 4
- Pages
- 456-469
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2134525555
- Cited by
- 386
- References
- 27
- FWCI
- 7.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.