In 1991, a novel robot, MIT-MANUS, was introduced to study the potential that robots might assist in and quantify the neuro-rehabilitation of motor function. MIT-MANUS proved an excellent tool for shoulder and elbow rehabilitation in stroke patients, showing in clinical trials a reduction of impairment in movements confined to the exercised joints. This successful proof of principle as to additional targeted and intensive movement treatment prompted a test of robot training examining other limb segments. This paper focuses on a robot for wrist rehabilitation designed to provide three rotational degrees-of-freedom. The first clinical trial of the device will enroll 200 stroke survivors. Ultimately 160 stroke survivors will train with both the proximal shoulder and elbow MIT-MANUS robot, as well as with the novel distal wrist robot, in addition to 40 stroke survivor controls. So far 52 stroke patients have completed the robot training (ongoing protocol). Here, we report on the initial results on 36 of these volunteers. These results demonstrate that further improvement should be expected by adding additional training to other limb segments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Technique to improve chronic motor deficit after stroke.
Taub, E., Miller, N. E., Novack, T. A., Cook, E. W., Fleming, W. C., Nepomuceno, C., Connell, J., & Crago, J. E. (1993) · PubMed · Cited by 1,557
Motor Control: Theory and Practical Applications
Shumway‐Cook, A., & Woollacott, M. H. (1995) · Cited by 1,494
Robot-aided neurorehabilitation
Krebs, H. I., Hogan, N., Aisen, M. L., & Volpe, B. T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.662623 · Cited by 1,425
Self-citationTreatment-Induced Cortical Reorganization After Stroke in Humans
Liepert, J., Bauder, H., Miltner, W. H. R., Taub, E., & Weiller, C. (2000) · Stroke · doi:10.1161/01.str.31.6.1210 · Cited by 1,404
Motor Control: Theory and practical applications
Lennon, S. (1996) · Physiotherapy · doi:10.1016/s0031-9406(05)66312-2 · Cited by 1,205
Recovery of upper extremity function in stroke patients: The Copenhagen stroke study
Nakayama, H., Stig Jørgensen, H., Otto Raaschou, H., & Skyhøj Olsen, T. (1994) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/0003-9993(94)90161-9 · Cited by 1,056
Consolidation in human motor memory
Brashers-Krug, T., Shadmehr, R., & Bizzi, E. (1996) · Nature · doi:10.1038/382252a0 · Cited by 985
THE RESTORATION OF MOTOR FUNCTION FOLLOWING HEMIPLEGIA IN MAN
TWITCHELL, T. E. (1951) · Brain · doi:10.1093/brain/74.4.443 · Cited by 940
Early stroke treatment associated with better outcome: The NINDS rt-PA Stroke Study
Marler, J. R., Tilley, B. C., Lu, M., Brott, T. G., Lyden, P. C., Grotta, J. C., Broderick, J. P., Levine, S. R., Frankel, M. P., Horowitz, S. H., et al. (2000) · Neurology · doi:10.1212/wnl.55.11.1649 · Cited by 862
van der Lee, J. H., Wagenaar, R. C., Lankhorst, G. J., Vogelaar, T. W., Devillé, W. L., & Bouter, L. M. (1999) · Stroke · doi:10.1161/01.str.30.11.2369 · Cited by 745
Cited by
A survey on robotic devices for upper limb rehabilitation
Maciejasz, P., Eschweiler, J., Gerlach-Hahn, K., Jansen-Troy, A., & Leonhardt, S. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-3 · Cited by 1,210
Review of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, L., & Reinkensmeyer, D. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-20 · Cited by 1,182
Mehrholz, J., Pohl, M., Platz, T., Kugler, J., & Elsner, B. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006876.pub4 · Cited by 678
Mehrholz, J., Pohl, M., Platz, T., Kugler, J., & Elsner, B. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006876.pub5 · Cited by 402
Robot-assisted rehabilitation of hand function
Balasubramanian, S., Klein, J., & Burdet, E. (2010) · Current Opinion in Neurology · doi:10.1097/wco.0b013e32833e99a4 · Cited by 287
Mehrholz, J., Hädrich, A., Platz, T., Kugler, J., & Pohl, M. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006876.pub3 · Cited by 274
An EMG-Controlled Exoskeleton for Hand Rehabilitation
Mulas, M., Folgheraiter, M., & Gini, G. (2005) · 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005. · doi:10.1109/icorr.2005.1501122 · Cited by 225
Mehrholz, J., Platz, T., Kugler, J., & Pohl, M. (2008) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006876.pub2 · Cited by 219
Hu, X. L., Tong, K.-Y., Song, R., Zheng, X. J., & Leung, W. W. F. (2009) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968309338191 · Cited by 212
“These observations were consistent with previous findings that poststroke training on the distal joints could increase the motor capacity related to the intralimb proximal joint.(20,21) In this study, we found a total change of 9 points in the FMA (max 66) for the interactive group after the training with an admission…”
ResultAdaptive Human–Robot Interaction Control for Robots Driven by Series Elastic Actuators
Li, X., Pan, Y., Chen, G., & Yu, H. (2017) · IEEE Transactions on Robotics · doi:10.1109/tro.2016.2626479 · Cited by 203
“IN RECENT years, rapid advances in computing and sensor technologies have led to the development of a variety of initiatives that involve physical interactions with humans, such as rehabilitation robots [1]–[3] and exoskeleton or wearable robots”
BackgroundAn IoT-Enabled Stroke Rehabilitation System Based on Smart Wearable Armband and Machine Learning
Yang, G., Deng, J., Pang, G., Zhang, H., Li, J., Deng, B., Pang, Z., Xu, J., Jiang, M., Liljeberg, P., et al. (2018) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2018.2822681 · Cited by 191
“One-on-one interaction with a therapist who assists and motivates the patient is generally involved in conventional therapy, where patient’s willingness of the involvement is low due the day-by-day repeated passive training [3], [4].”
BackgroundBabaiasl, M., Mahdioun, S. H., Jaryani, P., & Yazdani, M. (2015) · Disability and Rehabilitation: Assistive Technology · doi:10.3109/17483107.2014.1002539 · Cited by 182
“In the second class, the focus of training is on distal parts of the human arm such as hand [27], the wrist and the lower arm [28,29].”
BackgroundMethodStaubli, P., Nef, T., Klamroth-Marganska, V., & Riener, R. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-46 · Cited by 181
Liao, W.-W., Wu, C.-Y., Hsieh, Y.-W., Lin, K.-C., & Chang, W.-Y. (2012) · Clinical Rehabilitation · doi:10.1177/0269215511416383 · Cited by 172
“Moreover, wrists and forearms play an important role in enhancing object manipulations that are required for almost all everyday tasks.(42,43) Therefore, a robotic type of wrist and forearm training could be beneficial for arm activity and daily function recovery of stroke patients.”
BackgroundHigh-Density Myoelectric Pattern Recognition Toward Improved Stroke Rehabilitation
Zhang, X., & Zhou, P. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2191551 · Cited by 170
“, the MIT-Manus robot [4], [5] and the MIME robot [6], [7]) have been designed as assistive tools for robot-aided stroke rehabilitation to improve upper limb function [3]–[14].”
MethodBrain-Computer Interface-Based Soft Robotic Glove Rehabilitation for Stroke
Cheng, N., Phua, K. S., Lai, H. S., Tam, P. K., Tang, K. Y., Cheng, K. K., Yeow, R. C.-H., Ang, K. K., Guan, C., & Lim, J. H. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.2984003 · Cited by 165
“, Amadeo [14], [15] and MIT-Manus [16], [17], exoskeleton, e.”
A paradigm shift for rehabilitation robotics
Krebs, H., Dipietro, L., Levy-Tzedek, S., Fasoli, S., Rykman-Berland, A., Zipse, J., Fawcett, J., Stein, J., Poizner, H., Lo, A., et al. (2008) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2008.919498 · Cited by 162
Self-citationLambercy, O., Dovat, L., Yun, H., Wee, S. K., Kuah, C. W., Chua, K. S., Gassert, R., Milner, T. E., Teo, C. L., & Burdet, E. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-63 · Cited by 144
“elbow and shoulder, which may lead to improved control of the entire arm [10,12,13].”
BackgroundMethodResultInfluentialAtashzar, S. F., Polushin, I. G., & Patel, R. V. (2017) · IEEE Transactions on Robotics · doi:10.1109/tro.2016.2623336 · Cited by 57
“PVT is an interactive virtual-reality-based environment that can provide the patient with assistive and resistive therapeutic forces during various tasks [2], [9].”
Background(2008) · doi:10.1109/aim.2008.4601855 · Cited by 15
“motion capture system for objective diagnoses [1] and humancentered robots for assistance [2-6] and for rehabilitation [ 7- 9 ].”
Background
Metadata
- Authors
- Krebs, H. I., Volpe, B. T., Williams, D., Celestino, J., Charles, S. K., Lynch, D., & Hogan, N.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2007-09
- Volume
- 15
- Issue
- 3
- Pages
- 327-335
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2100970834
- Cited by
- 553
- References
- 40
- FWCI
- 20.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.