Improved Myoelectric Prosthesis Control Using Targeted Reinnervation Surgery: A Case Series
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Targeted reinnervation is a surgical technique developed to increase the number of myoelectric input sites available to control an upper-limb prosthesis. Because signals from the nerves related to specific movements are used to control those missing degrees-of-freedom, the control of a prosthesis using this procedure is more physiologically appropriate compared to conventional control. This procedure has successfully been performed on three people with a shoulder disarticulation level amputation and three people with a transhumeral level amputation. Performance on timed tests, including the box-and-blocks test and clothespin test, has increased two to six times. Options for new control strategies are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743 · cited 1×
“It is possible, with more advanced control algorithms such as pattern recognition, to utilize more information from the targeted reinnervation muscle [21].”
MethodKuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583 · cited 3×
“In these patients, a combination of segmented pectoralis major, pectoralis minor, serratus anterior and latissimus dorsi muscles were used (see [9] and [10] for surgical detail).”
BackgroundMethodSelf-citationBION ™ system for distributed neural prosthetic interfaces
Loeb, G. E., Peck, R. A., Moore, W. H., & Hood, K. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00011-x · Cited by 243 · cited 1×
“Another promising technology that could benefit TMR is implantable myoelectric electrode systems (IMES) [19], [20].”
BackgroundDecoding a New Neural–Machine Interface for Control of Artificial Limbs
Zhou, P., Lowery, M. M., Englehart, K. B., Huang, H., Li, G., Hargrove, L., Dewald, J. P. A., & Kuiken, T. A. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00178.2007 · Cited by 215 · cited 1×
“The bilateral shoulder disarticulation level subject achieved higher than 90% accuracies in pattern recognition testing [22].”
BackgroundSelf-citation
Cited by
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
“Currently the latter devices tend to be easier to use and offer better benefit/cost ratios [258,259].”
BackgroundLiterature Review on Needs of Upper Limb Prosthesis Users
Cordella, F., Ciancio, A. L., Sacchetti, R., Davalli, A., Cutti, A. G., Guglielmelli, E., & Zollo, L. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00209 · Cited by 752
Control of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Upper limb amputees can be induced to experience a rubber hand as their own
Ehrsson, H. H., Rosen, B., Stockselius, A., Ragno, C., Kohler, P., & Lundborg, G. (2008) · Brain · doi:10.1093/brain/awn297 · Cited by 343
Ison, M., & Artemiadis, P. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/051001 · Cited by 225
“However, recent advances with targeted muscle reinnervation (TMR) surgery [268], in which nerves associated with amputated muscles are redirected to residual muscle to form new functional connections, have provided an opportunity detect contractions from a full assortment of major muscles on subjects with amputations…”
Background
Metadata
- Authors
- Miller, L. A., Stubblefield, K. A., Lipschutz, R. D., Lock, B. A., & Kuiken, T. A.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2008-02
- Volume
- 16
- Issue
- 1
- Pages
- 46-50
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2148108509
- Cited by
- 157
- References
- 4
- FWCI
- 7.89
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.