An Adaptive P300-Based Online Brain–Computer Interface
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
The P300 component of an event related potential is widely used in conjunction with brain-computer interfaces (BCIs) to translate the subjects intent by mere thoughts into commands to control artificial devices. A well known application is the spelling of words while selection of the letters is carried out by focusing attention to the target letter. In this paper, we present a P300-based online BCI which reaches very competitive performance in terms of information transfer rates. In addition, we propose an online method that optimizes information transfer rates and/or accuracies. This is achieved by an algorithm which dynamically limits the number of subtrial presentations, according to the subject's current online performance in real-time. We present results of two studies based on 19 different healthy subjects in total who participated in our experiments (seven subjects in the first and 12 subjects in the second one). In the first, study peak information transfer rates up to 92 bits/min with an accuracy of 100% were achieved by one subject with a mean of 32 bits/min at about 80% accuracy. The second experiment employed a dynamic classifier which enables the user to optimize bitrates and/or accuracies by limiting the number of subtrial presentations according to the current online performance of the subject. At the fastest setting, mean information transfer rates could be improved to 50.61 bits/min (i.e., 13.13 symbols/min). The most accurate results with 87.5% accuracy showed a transfer rate of 29.35 bits/min.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 1×
“A more detailed discussion of the different types of BCIs can be found in [ 6 ].”
BackgroundThe Design and Implementation of FFTW3
Frigo, M., & Johnson, S. G. (2005) · Proceedings of the IEEE · doi:10.1109/jproc.2004.840301 · Cited by 5,086 · cited 1×
“Each channel was bandpass filtered with upper and lower corner frequencies of 1 and 9 Hz (using a DFT of the FFTW library [ 13 ]).”
MethodFarwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 2×
“P300-Speller Paradigm. The experimental setup consists of a computer CRT screen that displays a 6 6 matrix consisting of the letters A–Z and the digits 0–9 (see Fig. 1). According to [ 1 ], the term event denotes the intensification of either a row”
BackgroundEvoked-potential correlates of stimulus uncertainty
Sutton, S., Braren, M., Zubin, J., & John, E. R. (1965) · Science · doi:10.1126/science.150.3700.1187 · Cited by 3,061 · cited 1×
“Our BCI is based on a modifiedOddballParadigm [ 11 ] called”
MethodReport of the committee on methods of clinical examination in electroencephalography
(1958) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(58)90053-1 · Cited by 2,717
Mu rhythm (de)synchronization and EEG single-trial classification of different motor imagery tasks
Pfurtscheller, G., Brunner, C., Schlögl, A., & Lopes da Silva, F. H. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.12.003 · Cited by 1,587 · cited 1×
“Examples for the most common types are slow cortical potentials [2], mu and beta rhythms [3], event related (de)synchronization [ 4 ], and steady-state visual evoked potentials [5].”
BackgroundBrain-computer interfaces based on the steady-state visual-evoked response
Middendorf, M., McMillan, G., Calhoun, G., & Jones, K. S. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847819 · Cited by 685 · cited 1×
“Examples for the most common types are slow cortical potentials [2], mu and beta rhythms [3], event related (de)synchronization [4], and steady-state visual evoked potentials [ 5 ].”
BackgroundBCI Competition 2003—Data Set IIb: Support Vector Machines for the P300 Speller Paradigm
Kaper, M., Meinicke, P., Grossekathoefer, U., Lingner, T., & Ritter, H. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826698 · Cited by 496 · cited 1×
“Taking the offline BCI of Kaper that was ranked at first place in [ 14 ] as our basis, the classification system was modified to an online version and a first experiment to assess its performance was conducted.”
MethodSelf-citationAn improved P300-based brain-computer interface
Serby, H., Yom-Tov, E., & Inbar, G. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.841878 · Cited by 403 · cited 5×
“A similar approach was introduced by [ 7 ] which also adapts to the subjects online performance by limiting the number of subtrial presentations.”
BackgroundMethodResultInfluentialThe Wadsworth Center brain-computer interface (BCI) research and development program
Wolpaw, J. R., McFarland, D. J., Vaughan, T. M., & Schalk, G. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814442 · Cited by 209 · cited 1×
“Examples for the most common types are slow cortical potentials [2], mu and beta rhythms [ 3 ], event related (de)synchronization [4], and steady-state visual evoked potentials [5].”
Background
Cited by
Brain–computer interfaces in neurological rehabilitation
Daly, J. J., & Wolpaw, J. R. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70223-0 · Cited by 1,149
Townsend, G., LaPallo, B. K., Boulay, C. B., Krusienski, D. J., Frye, G. E., Hauser, C. K., Schwartz, N. E., Vaughan, T. M., Wolpaw, J. R., & Sellers, E. W. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.030 · Cited by 570
“Although they did not correct for errors (similar to this study), Lenhardt et al. (2008) reported the highest P300 online accuracies and bit rates prior to this study.”
BackgroundMethodResultInfluentialSimon, N., Käthner, I., Ruf, C. A., Pasqualotto, E., Kübler, A., & Halder, S. (2015) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.01039 · Cited by 478
Visual and Auditory Brain–Computer Interfaces
Gao, S., Wang, Y., Gao, X., & Hong, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2300164 · Cited by 449
Brain-Computer Interfaces Using Electrocorticographic Signals
Schalk, G., & Leuthardt, E. C. (2011) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2011.2172408 · Cited by 427
(C)overt attention and visual speller design in an ERP-based brain-computer interface
Treder, M. S., & Blankertz, B. (2010) · Behavioral and Brain Functions · doi:10.1186/1744-9081-6-28 · Cited by 362
Allison, B. Z., & Neuper, C. (2010) · Human-Computer Interaction Series · doi:10.1007/978-1-84996-272-8_3 · Cited by 350
Toward Unsupervised Adaptation of LDA for Brain–Computer Interfaces
Vidaurre, C., Kawanabe, M., von Bünau, P., Blankertz, B., & Müller, K. R. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2093133 · Cited by 296
Does the ‘P300’ speller depend on eye gaze?
Brunner, P., Joshi, S., Briskin, S., Wolpaw, J. R., Bischof, H., & Schalk, G. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/5/056013 · Cited by 291
A New Auditory Multi-Class Brain-Computer Interface Paradigm: Spatial Hearing as an Informative Cue
Schreuder, M., Blankertz, B., & Tangermann, M. (2010) · PLoS ONE · doi:10.1371/journal.pone.0009813 · Cited by 276
A novel hybrid BCI speller based on the incorporation of SSVEP into the P300 paradigm
Yin, E., Zhou, Z., Jiang, J., Chen, F., Liu, Y., & Hu, D. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026012 · Cited by 225
“time by using too many trials [39].”
N200-speller using motion-onset visual response
Hong, B., Guo, F., Liu, T., Gao, X., & Gao, S. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.06.026 · Cited by 192
“Up to the present, P300 related BCI has focused on feature extraction and classification procedures to enhance the information transfer rate and applicability of the system (Xu et al., 2004; Serby et al., 2005; Thulasidas et al., 2006; Piccione et al., 2006; Zhang et al., 2008; Lenhardt et al., 2008; Nijboer et al., 2…”
BackgroundThe MindGame: A P300-based brain–computer interface game
Finke, A., Lenhardt, A., & Ritter, H. (2009) · Neural Networks · doi:10.1016/j.neunet.2009.07.003 · Cited by 175
Self-citationA Speedy Hybrid BCI Spelling Approach Combining P300 and SSVEP
Yin, E., Zhou, Z., Jiang, J., Chen, F., Liu, Y., & Hu, D. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2281976 · Cited by 167
“First, in addition to different individuals having different spelling capabilities when using the P300 and SSVEP spellers, the performance of any one individual varies to some extent from one recording session to the next [39], [40].”
BackgroundA High Performance Spelling System based on EEG-EOG Signals With Visual Feedback
Lee, M.-H., Williamson, J., Won, D.-O., Fazli, S., & Lee, S.-W. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2839116 · Cited by 163
“Lenhardt et al. [71] proposed the P300 speller system which dynamically limits the number of subtrial presentations according to the user’s current online performance.”
BackgroundKaufmann, T., Herweg, A., & Kübler, A. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-7 · Cited by 159
“, [56-60]; for comparison of techniques [61,62]).”
BackgroundAn adaptive P300-based control system
Jin, J., Allison, B. Z., Sellers, E. W., Brunner, C., Horki, P., Wang, X., & Neuper, C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036006 · Cited by 158
“Indeed, this precedent was established in the first P300 BCI paper (Farwell and Donchin 1988) and has since become commonplace (Lenhardt et al 2008, Krusienski et al 2008, Jin et al 2010a).”
BackgroundMethodInfluentialEffects of training and motivation on auditory P300 brain-computer interface performance
Baykara, E., Ruf, C. A., Fioravanti, C., Käthner, I., Simon, N., Kleih, S. C., Kübler, A., & Halder, S. (2016) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.04.054 · Cited by 91
“…86.1 5.13 Online Healthy Hill and Schölkopf (2012) Auditory 2 84.8 4.38 Online Healthy Nijboer et al. (2008b) Visual 36 78.8 9.7 Online ALS patients Lenhardt et al. (2008) Visual 36 65.5 – 87.5 29.35 – 50.61 Online Healthy Furdea et al. (2009) Visual 36 94.6 6.8 Online Healthy Kaufmann and Kübler…”
InfluentialFuhrmann Alpert, G., Manor, R., Spanier, A. B., Deouell, L. Y., & Geva, A. B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2289898 · Cited by 74
“observer has in mind, are reported to achieve near 76%–80% single-trial classification accuracy [27], [28].”
BackgroundAsynchronous gaze-independent event-related potential-based brain–computer interface
Aloise, F., Aricò, P., Schettini, F., Salinari, S., Mattia, D., & Cincotti, F. (2013) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2013.07.006 · Cited by 43
Metadata
- Authors
- Lenhardt, A., Kaper, M., & Ritter, H. J.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2008-04
- Volume
- 16
- Issue
- 2
- Pages
- 121-130
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2148475805
- Cited by
- 190
- References
- 14
- FWCI
- 8.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.