The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Assistive Control System Using Continuous Myoelectric Signal in Robot-Aided Arm Training for Patients After Stroke
Abstract
In some stroke rehabilitation programs, robotic systems have been used to aid the patient to train. In this study, a myoelectrically controlled robotic system with 1 degree-of-freedom was developed to assist elbow training in a horizontal plane with intention involvement for people after stroke. The system could provide continuous assistance in extension torque, which was proportional to the amplitude of the subject's electromyographic (EMG) signal from the triceps, and could provide resistive torques during movement. This study investigated the system's effect on restoring the upper limb functions of eight subjects after chronic stroke in a twenty-session rehabilitation training program. In each session, there were 18 trials comprising different combinations of assistive and resistive torques and an evaluation trial. Each trial consisted of five cycles of repetitive elbow flexion and extension between 90 degrees and 0 degrees at a constant velocity of 10 degrees/s. With the assistive extension torque, subjects could reach a more extended position in the first session. After 20 sessions of training, there were statistically significant improvements in the modified Ashworth scale, Fugl-Meyer scale for shoulder and elbow, motor status scale, elbow extension range, muscle strength, and root mean square error between actual elbow angle and target angle. The results showed that the twenty-session training program improved upper limb functions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ouellette, M. M., LeBrasseur, N. K., Bean, J. F., Phillips, E., Stein, J., Frontera, W. R., & Fielding, R. A. (2004) · Stroke · doi:10.1161/01.str.0000127785.73065.34 · Cited by 334
Cited by
Review of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, L., & Reinkensmeyer, D. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-20 · Cited by 1,182
Rehabilitation of gait after stroke: a review towards a top-down approach
Belda-Lois, J.-M., Mena-del Horno, S., Bermejo-Bosch, I., Moreno, J. C., Pons, J. L., Farina, D., Iosa, M., Molinari, M., Tamburella, F., Ramos, A., et al. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-66 · Cited by 581
Recent development of mechanisms and control strategies for robot-assisted lower limb rehabilitation
Meng, W., Liu, Q., Zhou, Z., Ai, Q., Sheng, B., & Xie, S. (. (2015) · Mechatronics · doi:10.1016/j.mechatronics.2015.04.005 · Cited by 464
Basteris, A., Nijenhuis, S. M., Stienen, A. H., Buurke, J. H., Prange, G. B., & Amirabdollahian, F. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-111 · Cited by 408
Intention-Based EMG Control for Powered Exoskeletons
Lenzi, T., De Rossi, S. M. M., Vitiello, N., & Carrozza, M. C. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2198821 · Cited by 400
Metadata
- Authors
- Song, R., Tong, K.-Y., Hu, X., & Li, L.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2008-08
- Volume
- 16
- Issue
- 4
- Pages
- 371-379
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2148796737
- Cited by
- 195
- References
- 1
- FWCI
- 8.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assistive Control System Using Continuous Myoelectric Signal in Robot-Aided Arm Training for Patients After Stroke. https://app.cochat.ai/papers/10.1109/tnsre.2008.926707
- The paper
- Song, R., Tong, K.-Y., Hu, X., & Li, L. (2008). Assistive Control System Using Continuous Myoelectric Signal in Robot-Aided Arm Training for Patients After Stroke. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2008.926707
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.