Assistive Control System Using Continuous Myoelectric Signal in Robot-Aided Arm Training for Patients After Stroke
The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
In some stroke rehabilitation programs, robotic systems have been used to aid the patient to train. In this study, a myoelectrically controlled robotic system with 1 degree-of-freedom was developed to assist elbow training in a horizontal plane with intention involvement for people after stroke. The system could provide continuous assistance in extension torque, which was proportional to the amplitude of the subject's electromyographic (EMG) signal from the triceps, and could provide resistive torques during movement. This study investigated the system's effect on restoring the upper limb functions of eight subjects after chronic stroke in a twenty-session rehabilitation training program. In each session, there were 18 trials comprising different combinations of assistive and resistive torques and an evaluation trial. Each trial consisted of five cycles of repetitive elbow flexion and extension between 90 degrees and 0 degrees at a constant velocity of 10 degrees/s. With the assistive extension torque, subjects could reach a more extended position in the first session. After 20 sessions of training, there were statistically significant improvements in the modified Ashworth scale, Fugl-Meyer scale for shoulder and elbow, motor status scale, elbow extension range, muscle strength, and root mean square error between actual elbow angle and target angle. The results showed that the twenty-session training program improved upper limb functions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The post-stroke hemiplegic patient. 1. a method for evaluation of physical performance
Fugl-Meyer, A., Jääskö, L., Leyman, I., Olsson, S., & Steglind, S. (1975) · Journal of Rehabilitation Medicine · doi:10.2340/1650197771331 · Cited by 5,564
Interrater Reliability of a Modified Ashworth Scale of Muscle Spasticity
Bohannon, R. W., & Smith, M. B. (1987) · Physical Therapy · doi:10.1093/ptj/67.2.206 · Cited by 5,424
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 1×
“EMG signals have been frequently applied in the control of prosthetics for more than forty years and can be classified in “on–off” control [21], proportional control [22], and a more complex form, for distinguishing different kinds of motion [19], [20].”
BackgroundThe Atlas of Heart Disease and Stroke
Mackay, J., Mensah, G. A., & Mendis, S. (2004) · Medical Entomology and Zoology · Cited by 1,550
PRELIMINARY TRIAL OF CARISOPRODOL IN MULTIPLE SCLEROSIS.
Ashworth, B. (1964) · PubMed · Cited by 1,475
Robot-aided neurorehabilitation
Krebs, H. I., Hogan, N., Aisen, M. L., & Volpe, B. T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.662623 · Cited by 1,425 · cited 2×
“MIT-Manus is a robotic system designed for upper limb stroke rehabilitation [5], [8].”
BackgroundMotor learning: its relevance to stroke recovery and neurorehabilitation
Krakauer, J. W. (2006) · Current Opinion in Neurology · doi:10.1097/01.wco.0000200544.29915.cc · Cited by 1,275 · cited 1×
“The criteria for recruiting the subjects included the following: 1) there should be at least six months after unilateral stroke in order to minimize the effect of spontaneous recovery [ 49 ] (the mean duration from stroke onset was 5.7 4.2 years, ranging from 10 months to 13 years), 2) the subjects should not have vis…”
BackgroundInfluentialThe atlas of heart disease and stroke
Beevers, D. G. (2005) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001852 · Cited by 1,247
Development of robots for rehabilitation therapy: the Palo Alto VA/Stanford experience.
Burgar, C. G., Lum, P. S., Shor, P. C., & der Loos, H. F. M. V. (2000) · PubMed · Cited by 800
A wavelet-based continuous classification scheme for multifunction myoelectric control
Englehart, K., Hudgin, B., & Parker, P. A. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914793 · Cited by 697 · cited 1×
“EMG signals have been frequently applied in the control of prosthetics for more than forty years and can be classified in “on–off” control [21], proportional control [22], and a more complex form, for distinguishing different kinds of motion [19], [20].”
BackgroundSpastic hypertonia: mechanisms and measurement.
Katz, R. T., & Rymer, W. Z. (1989) · PubMed · Cited by 624
Spasticity and muscle contracture following stroke
O'Dwyer, N. J., Ada, L., & Neilson, P. D. (1996) · Brain · doi:10.1093/brain/119.5.1737 · Cited by 616 · cited 1×
“However, it is difficult or even impossible for such patients to reach an extended elbow position due to contracture [45], spasticity [46] or muscle weakness [38], [47].”
BackgroundA novel approach to stroke rehabilitation: Robot-aided sensorimotor stimulation
Volpe, B. T., Krebs, H. I., Hogan, N., Edelstein, L., Diels, C., & Aisen, M. (2000) · Neurology · doi:10.1212/wnl.54.10.1938 · Cited by 582
Reinkensmeyer, D. J., Kahn, L. E., Averbuch, M., McKenna-Cole, A. N., Schmit, B. D., & Rymer, W. Z. (2000) · PubMed · Cited by 558
The Effect of Robot-Assisted Therapy and Rehabilitative Training on Motor Recovery Following Stroke
Aisen, M. L., Krebs, H. I., Hogan, N., McDowell, F., & Volpe, B. T. (1997) · Archives of Neurology · doi:10.1001/archneur.1997.00550160075019 · Cited by 516 · cited 1×
“Its therapeutic effect has been confirmed through a series of experiments [12]–[14].”
BackgroundHesse, S., Schulte-Tigges, G., Konrad, M., Bardeleben, A., & Werner, C. (2003) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(02)04954-7 · Cited by 489
Increasing productivity and quality of care: robot-aided neuro-rehabilitation.
Krebs, H. I., Volpe, B. T., Aisen, M. L., & Hogan, N. (2000) · PubMed · Cited by 441
A myosignal-based powered exoskeleton system
Rosen, J., Brand, M., Fuchs, M. B., & Arcan, M. (2001) · IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans · doi:10.1109/3468.925661 · Cited by 437 · cited 3×
“In such studies, the system is under the control of the subject’s intention, functioning like additional muscle groups [26]–[29].”
BackgroundMethodRobot-aided neurorehabilitation of the upper extremities
Riener, R., Nef, T., & Colombo, G. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345116 · Cited by 407 · cited 1×
“Recent developments involving rehabilitation robots have worked toward interactive control, with the robotic systems reacting to inputs from the subject [11].”
BackgroundRobotic techniques for upper limb evaluation and rehabilitation of stroke patients
Colombo, R., Pisano, F., Micera, S., Mazzone, A., Delconte, C., Carrozza, M. C., Dario, P., & Minuco, G. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848352 · Cited by 399 · cited 6×
“They used admittance control to reduce the inertia and facilitate the movement [6].”
BackgroundMethodResultInfluentialMotions or muscles? Some behavioral factors underlying robotic assistance of motor recovery
Hogan, N., Krebs, H. I., Rohrer, B., Palazzolo, J. J., Dipietro, L., Fasoli, S. E., Stein, J., Hughs, R., Frontera, W. R., Lynch, D., et al. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.06.0103 · Cited by 374 · cited 1×
“tance therapy [48], while other studies reported that high-intensity resistance training is effective for developing muscle”
BackgroundCauraugh, J., Light, K., Kim, S., Thigpen, M., & Behrman, A. (2000) · Stroke · doi:10.1161/01.str.31.6.1360 · Cited by 351 · cited 4×
“control of functional electrical stimulation (FES) systems in rehabilitation [18], [23], [24], since voluntary physical exercise is important to promote the recovery of brain function in patients after stroke [17].”
BackgroundMethodInfluentialOuellette, M. M., LeBrasseur, N. K., Bean, J. F., Phillips, E., Stein, J., Frontera, W. R., & Fielding, R. A. (2004) · Stroke · doi:10.1161/01.str.0000127785.73065.34 · Cited by 334 · cited 1×
“The clinical effect of resistive torque is still controversial, with some studies showing that there is no significant difference between robotic progressive-resistance therapy and active-assistance therapy [48], while other studies reported that high-intensity resistance training is effective for developing muscle st…”
ResultMIT-MANUS: a workstation for manual therapy and training. I
Hogan, N., Krebs, H. I., Charnnarong, J., Srikrishna, P., & Sharon, A. (2003) · [1992] Proceedings IEEE International Workshop on Robot and Human Communication · doi:10.1109/roman.1992.253895 · Cited by 314 · cited 3×
“MIT-Manus is a robotic system designed for upper limb stroke rehabilitation [ 5 ], [8].”
BackgroundMethodInfluentialHigh Intensity Strength Training Improves Strength and Functional Performance After Stroke
Weiss, A., Suzuki, T., Bean, J., & Fielding, R. A. (2000) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-200007000-00009 · Cited by 304 · cited 1×
“strength [40], [41].”
Lum, P. S., Burgar, C. G., & Shor, P. C. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.827225 · Cited by 281 · cited 1×
“Mirror-image movement enabler (MIME) is 3-D space [10], [15].”
BackgroundArm Training Induced Brain Plasticity in Stroke Studied with Serial Positron Emission Tomography
Nelles, G., Jentzen, W., Jueptner, M., Müller, S., & Diener, H. C. (2001) · NeuroImage · doi:10.1006/nimg.2001.0757 · Cited by 255 · cited 1×
“Interactive Control: Although passive movements have been shown to have beneficial effects on restoring upper limb functions [42], rehabilitation training with the subject’s intention input, such as interactive control, is preferred [43] and widely applied in current rehabilitation robots.”
BackgroundCustomized interactive robotic treatment for stroke: EMG-triggered therapy
Dipietro, L., Ferraro, M., Palazzolo, J. J., Krebs, H. I., Volpe, B. T., & Hogan, N. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.850423 · Cited by 241 · cited 2×
“The use of myoelectrically controlled robot-aided therapy for subjects after stroke has so far been studied in an EMG-triggered “on–off” control [25].”
BackgroundOccupational Therapy for Physical Dysfunction
Nazzal, M., & Ismaeel, N. (2003) · Cited by 195
The influence of depression, social activity, and family stress on functional outcome after stroke.
Angeleri, F., Angeleri, V. A., Foschi, N., Giaquinto, S., & Nolfe, G. (1993) · Stroke · doi:10.1161/01.str.24.10.1478 · Cited by 173 · cited 1×
“Poststroke depression is also reported in patients after stroke with impaired QOL [4].”
BackgroundStein, J., Narendran, K., McBean, J., Krebs, K., & Hughes, R. (2007) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e3180383cc5 · Cited by 170 · cited 2×
“The improvements in Fugl–Meyer score for the shoulder and elbow, MSS, and modified Ashworth score in the present study were comparable with that reported in others’ work [6], [9], [36].”
BackgroundResultQuality of life after a first ischemic stroke
Jonkman, E. J., de Weerd, A. W., & Vrijens, N. L. H. (1998) · Acta Neurologica Scandinavica · doi:10.1111/j.1600-0404.1998.tb07289.x · Cited by 165
Guidance-based quantification of arm impairment following brain injury: a pilot study
Reinkensmeyer, D. J., Dewald, J. P. A., & Rymer, W. Z. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.750543 · Cited by 149 · cited 1×
“ARM Guide was designed for both training and evaluation of upper limb reaching functions in a linear trajectory [9], [ 16 ].”
MethodPerformances of Hill-Type and Neural Network Muscle Models—Toward a Myosignal-Based Exoskeleton
Rosén, J., Fuchs, M. B., & Arcan, M. (1999) · Computers and Biomedical Research · doi:10.1006/cbmr.1999.1524 · Cited by 142 · cited 1×
“However, Rosen et al. only applied the robotic system using continuous EMG control on normal subjects to share the loading [26], [ 27 ].”
MethodTHE USE OF MYO-ELECTRIC CURRENTS IN THE OPERATION OF PROSTHESES
Battye, C. K., Nightingale, A., & Whillis, J. (1955) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.37b3.506 · Cited by 129 · cited 1×
“EMG signals have been frequently applied in the control of prosthetics for more than forty years and can be classified in “on–off” control [21], proportional control [22], and a more complex form, for distinguishing different kinds of motion [19], [20].”
BackgroundCorrelates of Subjective Well-being in Stroke Patients
Wyller, T. B., Holmen, J., Laake, P., & Laake, K. (1998) · Stroke · doi:10.1161/01.str.29.2.363 · Cited by 119 · cited 1×
“Patients after stroke are often reported to have a lower quality of life (QOL), due to stroke-induced disabilities, than normal subjects of similar age [2], [3].”
BackgroundVariation of Muscle Coactivation Patterns in Chronic Stroke During Robot-Assisted Elbow Training
Hu, X., Tong, R. K., Song, R., Tsang, V. S., Leung, P. O., & Li, L. (2007) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.05.006 · Cited by 114 · cited 1×
“The improvement in extension range might also relate to the increase in muscle strength shown in Fig. 10 and the decrease in muscle cocontraction [ 39 ].”
BackgroundSelf-citationStroke patients have selective muscle weakness in shortened range
Ada, L., Canning, C. G., & Low, S.-L. (2003) · Brain · doi:10.1093/brain/awg066 · Cited by 109 · cited 2×
“However, it is difficult or even impossible for such patients to reach an extended elbow position due to contracture [45], spasticity [46] or muscle weakness [ 38 ], [47].”
BackgroundRobotic assistance of an active upper limb exercise in neurologically impaired patients
Cozens, J. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.769416 · Cited by 106 · cited 2×
“proposed an assist feedback control scheme that could detect spasticity from acceleration and provide a ramp torque in the movement if the acceleration was beyond the preset value [43].”
BackgroundFerraro, M., Demaio, J. H., Krol, J., Trudell, C., Rannekleiv, K., Edelstein, L., Christos, P., Aisen, M., England, J., Fasoli, S., et al. (2002) · Neurorehabilitation and Neural Repair · doi:10.1177/154596830201600306 · Cited by 105
Graupe, D. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32103 · Cited by 96 · cited 1×
“control of functional electrical stimulation (FES) systems in rehabilitation [18], [23], [24], since voluntary physical exercise is important to promote the recovery of brain function in patients after stroke [17].”
BackgroundMYO-ELECTRIC CONTROL OF POWERED PROSTHESES
Bottomley, A. H. (1965) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.47b3.411 · Cited by 86 · cited 1×
“EMG signals have been frequently applied in the control of prosthetics for more than forty years and can be classified in “on–off” control [21], proportional control [22], and a more complex form, for distinguishing different kinds of motion [19], [20].”
BackgroundPower assist control for leg with HAL-3 based on virtual torque and impedance adjustment
Lee, S., & Sankai, Y. (2002) · IEEE International Conference on Systems, Man and Cybernetics · doi:10.1109/icsmc.2002.1173329 · Cited by 75 · cited 1×
“In such studies, the system is under the control of the subject’s intention, functioning like additional muscle groups [26]–[29].”
BackgroundEffect of muscle length on strength and dexterity after stroke
Ada, L., Canning, C. G., & Dwyer, T. (2000) · Clinical Rehabilitation · doi:10.1191/026921500671430626 · Cited by 53 · cited 1×
“voluntary efforts. Ada et al. suggested that the training of muscles at their shortened lengths was more effective in developing muscle strength in patients after stroke as they have selective muscle weakness at shortened ranges [ 37 ], [38].”
BackgroundImproving Elbow Torque Output of Stroke Patients with Assistive Torque Controlled by EMG Signals
Cheng, H., Ju, M., & Lin, C. K. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1634284 · Cited by 52 · cited 3×
“applied their system to provide continuous assistive torque for subjects after stroke [28].”
BackgroundMethodMuscle substitutes and myo-electric control
Bottomley, A. H., Wilson, A. B. K., & Nightingale, A. (1963) · Radio and Electronic Engineer · doi:10.1049/ree.1963.0169 · Cited by 40
Recent Advances in Stroke Rehabilitation
Hallett, M. (2002) · Neurorehabilitation and neural repair · doi:10.1177/08839002016002003 · Cited by 40
Graupe, D., Kohn, K. H., & Basseas, S. P. (1989) · IEEE Transactions on Automatic Control · doi:10.1109/9.21084 · Cited by 19 · cited 1×
“Myoelectric control has also been reported for the control of functional electrical stimulation (FES) systems in rehabilitation [18], [23], [ 24 ], since voluntary physical exercise is important to promote the recovery of brain function in patients after stroke [17].”
Background
Cited by
A survey on robotic devices for upper limb rehabilitation
Maciejasz, P., Eschweiler, J., Gerlach-Hahn, K., Jansen-Troy, A., & Leonhardt, S. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-3 · Cited by 1,210
Review of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, L., & Reinkensmeyer, D. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-20 · Cited by 1,182
Rehabilitation of gait after stroke: a review towards a top-down approach
Belda-Lois, J.-M., Mena-del Horno, S., Bermejo-Bosch, I., Moreno, J. C., Pons, J. L., Farina, D., Iosa, M., Molinari, M., Tamburella, F., Ramos, A., et al. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-66 · Cited by 581
Recent development of mechanisms and control strategies for robot-assisted lower limb rehabilitation
Meng, W., Liu, Q., Zhou, Z., Ai, Q., Sheng, B., & Xie, S. (. (2015) · Mechatronics · doi:10.1016/j.mechatronics.2015.04.005 · Cited by 464
Basteris, A., Nijenhuis, S. M., Stienen, A. H., Buurke, J. H., Prange, G. B., & Amirabdollahian, F. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-111 · Cited by 408
Metadata
- Authors
- Song, R., Tong, K.-Y., Hu, X., & Li, L.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2008-08
- Volume
- 16
- Issue
- 4
- Pages
- 371-379
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2148796737
- Cited by
- 195
- References
- 48
- FWCI
- 8.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.