A Self-Paced and Calibration-Less SSVEP-Based Brain–Computer Interface Speller
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
A brain-computer interface (BCI) is a communication system based on neural activity. Its goal is to provide a new output channel for the brain that requires voluntary control. We propose a new self-paced BCI speller based on the detection of steady-state visual evoked potential (SSVEP). The speller does not require any training from the user or from the signal processing part. The system is ready once the subject is prepared. The speller introduces a selection based on a decision tree and an undo command for correcting eventual errors. It was tested on eight healthy subjects who had no prior experience with the application. The average accuracy and information transfer rate are 92.25% and 37.62 bits per minute, which is translated in the speller with an average speed of 5.51 letters per minute.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Mathematical Theory of Communication
Shannon, C. E. (1948) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1948.tb00917.x · Cited by 48,949
The Mathematical Theory of Communication
Shannon, C. E., Weaver, W., & Wiener, N. (1950) · Physics Today · doi:10.1063/1.3067010 · Cited by 9,801
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Mathematical Theory of Communication
(2013) · Encyclopedia of Systems Biology · doi:10.1007/978-1-4419-9863-7_100015 · Cited by 3,290
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 1×
“Indeed, contrary to a P300-Speller [20], [21], where the user selects what he is looking at, BCIs based on SSVEP use the visual stimuli as a mean to navigate in one other interface or to control some devices [22], [23].”
BackgroundA review of classification algorithms for EEG-based brain–computer interfaces
Lotte, F., Congedo, M., Lécuyer, A., Lamarche, F., & Arnaldi, B. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r01 · Cited by 2,665
Optimizing Spatial filters for Robust EEG Single-Trial Analysis
Blankertz, B., Tomioka, R., Lemm, S., Kawanabe, M., & Muller, K.-R. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408441 · Cited by 2,080 · cited 1×
“enhancement of the relevant signal [16], [29], [30].”
BackgroundThe mental prosthesis: assessing the speed of a P300-based brain-computer interface
Donchin, E., Spencer, K. M., & Wijesinghe, R. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847808 · Cited by 1,222
Herrmann, C. S. (2001) · Experimental Brain Research · doi:10.1007/s002210100682 · Cited by 1,080 · cited 1×
“However, it is actually possible to get an SSVEP response with a large number of frequencies, from 1 to 100 Hz, with resonance peaks at 10, 20, 40, and 80 Hz [27].”
BackgroundBashashati, A., Fatourechi, M., Ward, R. K., & Birch, G. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r03 · Cited by 907
Cited by
Brain-Computer Interfaces in Medicine
Shih, J. J., Krusienski, D. J., & Wolpaw, J. R. (2012) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2011.12.008 · Cited by 724
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Brain–Computer Interface Spellers: A Review
Rezeika, A., Benda, M., Stawicki, P., Gembler, F., Saboor, A., & Volosyak, I. (2018) · Brain Sciences · doi:10.3390/brainsci8040057 · Cited by 391
Norton, J. J. S., Lee, D. S., Lee, J. W., Lee, W., Kwon, O., Won, P., Jung, S.-Y., Cheng, H., Jeong, J.-W., Akce, A., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1424875112 · Cited by 387
The Berlin Brain–Computer Interface: Non-Medical Uses of BCI Technology
Blankertz, B., Tangermann, M., Vidaurre, C., Fazli, S., Sannelli, C., Haufe, S., Maeder, C., Ramsey, L., Sturm, I., Curio, G., et al. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00198 · Cited by 357
“…by means of specifically developed machine learning techniques, e.g., Kaper and Ritter (2004), Lu et al. (2009) for P300 and Allison et al. (2008), Cecotti (2010) for SSVEP as well as Krauledat et al. (2008) for SMR-based BCIs where feedback and calibration data of multiple sessions of…”
MethodA high-ITR SSVEP-based BCI speller
Chen, X., Chen, Z., Gao, S., & Gao, X. (2014) · Brain-Computer Interfaces · doi:10.1080/2326263x.2014.944469 · Cited by 301
EEG-Based Brain-Computer Interfaces: A Thorough Literature Survey
Hwang, H.-J., Kim, S., Choi, S., & Im, C.-H. (2013) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2013.780869 · Cited by 257
“Recently, some BCI studies started to introduce SSVEP-based mental spelling systems (Cecotti, 2010; Hwang et al., 2012; Volosyak, 2011).”
BackgroundDevelopment of an SSVEP-based BCI spelling system adopting a QWERTY-style LED keyboard
Hwang, H.-J., Lim, J.-H., Jung, Y.-J., Choi, H., Lee, S. W., & Im, C.-H. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.04.011 · Cited by 251
“…in the case of using computer monitors for presenting visual stimuli, as in the most developed SSVEP spelling systems, stimulating frequencies have to be set as divisors of the monitor refreshing rate to attain accurate SSVEP responses (Yan et al., 2009; Cecotti, 2010; Zhu et al., 2010).”
InfluentialMultivariate synchronization index for frequency recognition of SSVEP-based brain–computer interface
Zhang, Y., Xu, P., Cheng, K., & Yao, D. (2014) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2013.07.018 · Cited by 233
Neurotechnologies for Human Cognitive Augmentation: Current State of the Art and Future Prospects
Cinel, C., Valeriani, D., & Poli, R. (2019) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2019.00013 · Cited by 178
“This allows the BCI to recognise the command a user intends to issue and can, therefore, be used for communication (Cecotti, 2010; Hwang et al., 2012; Yin et al., 2015).”
MethodA Speedy Hybrid BCI Spelling Approach Combining P300 and SSVEP
Yin, E., Zhou, Z., Jiang, J., Chen, F., Liu, Y., & Hu, D. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2281976 · Cited by 167
Comparing user-dependent and user-independent training of CNN for SSVEP BCI
Ravi, A., Beni, N. H., Manuel, J., & Jiang, N. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab6a67 · Cited by 165
To train or not to train? A survey on training of feature extraction methods for SSVEP-based BCIs
Zerafa, R., Camilleri, T., Falzon, O., & Camilleri, K. P. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaca6e · Cited by 160
“Training-free [8, 47], training-less [48], calibration-less [49], zero-training [15] and plug-and-play [9], all refer to methods that do not make use of any training data to extract SSVEP features.”
BackgroundMethodHeading for new shores! Overcoming pitfalls in BCI design
Chavarriaga, R., Fried-Oken, M., Kleih, S., Lotte, F., & Scherer, R. (2017) · Brain-Computer Interfaces · doi:10.1080/2326263x.2016.1263916 · Cited by 97
“, without calibration at all for a new user [78, 79].”
Metadata
- Authors
- Cecotti, H.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2010-04
- Volume
- 18
- Issue
- 2
- Pages
- 127-133
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2126617441
- Cited by
- 253
- References
- 40
- FWCI
- 9.96
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.