We present a new wearable haptic device that provides a sense of position and motion by inducing rotational skin stretch on the user's skin. In the experiments described in this paper, the device was used to provide proprioceptive feedback from a virtual prosthetic arm controlled with myoelectric sensors on the bicep and tricep muscles in 15 able-bodied participants. Targeting errors in blind movements with the haptic device were compared to cases where no feedback and contralateral proprioception were provided. Average errors were lower with the device than with no feedback but larger than with contralateral proprioceptive feedback. Participants also had lower visual demand with the device than with no feedback while tracking a 30 ( degrees ) moving range. The results indicate that the rotational skin stretch may ultimately be effective for proprioceptive feedback in myoelectric prostheses, particularly when vision is otherwise occupied.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tnsre.2009.2039602

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 30

  1. 10.1115/1.2168480 · doi:10.1115/1.2168480
  2. bjorklund, 2004, Effects of repetitive work on proprioception and of stretching on sensory mechanisms
  3. 10.1109/TRO.2007.910708 · DOI · Paper page
  4. 10.1080/00140138408963474 · doi:10.1080/00140138408963474
  5. hogan, 1984, Mechanical Impedance Control in Assistive Devices and Manipulators, 361
  6. 10.1115/1.533549 · DOI
  7. spanner, 2006, Survey of the various operating principles of ultrasonic piezomotors, Proc 10th Int Conf New Actuators
  8. 10.1007/BF02478123 · DOI
  9. 10.1518/001872005774859944 · DOI · Paper page
  10. 10.1177/154193120104502305 · DOI
  11. 10.1038/35053191 · DOI · Paper page
  12. 10.1109/ICORR.2007.4428474 · DOI
  13. 10.1097/00008526-199600810-00003 · DOI · Paper page
  14. carlson, 1992, Control of powered arm prosthesis with extended physiological proprioception, Proc 7th World Congress Int Soc Prosthetics Orthotics
  15. 10.3233/TAD-2003-15207 · doi:10.3233/tad-2003-15207
  16. 10.2106/00004623-199312000-00007 · DOI · Paper page
  17. simpson, 1974, The choice of control system for the multimovement prosthesis: Extended physiological proprioception (E.P.P.), The Control of Upper-Extremity Prostheses and Orthoses
  18. 10.1152/jn.00191.2005 · DOI · Paper page
  19. childress, 1993, Modification of a bock hand for E.P.P. control by exteriorized tendons, Proc 19th Annu Meeting Am Acad Orthotics Prosthetics, 13
  20. heckathorne, 1995, E.P.P. control of an electric hand by exteriorized forearm tendons, Proc 8th World Conf Int Soc Prosthetics Orthotics, 101
  21. f weir, 2001, Cineplasty as a control input for externally powered prosthetic components, J of Rehab Research & Development, 38, 357
  22. 10.1109/HAPTICS.2008.4479916 · DOI
  23. 10.1113/jphysiol.1995.sp020875 · DOI · Paper page
  24. 10.1109/WHC.2009.4810850 · DOI
  25. y rita, 1970, Sensory substitution and limb prostheses, Adv External Contr Human Extremities IX, 9
  26. 10.1243/PIME_CONF_1968_183_183_02 · DOI
  27. 10.1007/BF02442481 · DOI
  28. 10.1007/BF02478841 · DOI
  29. clippenger, 1974, A sensory feedback system for an upper-limb amputation prosthesis, Bull Prosthetics Res, 10, 247
  30. 10.1007/BF02440956 · DOI

Cited by

See all 146

Metadata

Authors
Wheeler, J., Bark, K., Savall, J., & Cutkosky, M.
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2010-02
Volume
18
Issue
1
Pages
58-66
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2133432855
Cited by
146
References
5
FWCI
3.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.