Cited by 573Neuroscience and Neural EngineeringMuscle activation and electromyography studiesEEG and Brain-Computer Interfaces

Direct neural sensory feedback and control of a prosthetic arm

Dhillon, G.S., Horch, K.W.·2005·IEEE Transactions on Neural Systems and Rehabilitation Engineering

Abstract

Evidence indicates that user acceptance of modern artificial limbs by amputees would be significantly enhanced by a system that provides appropriate, graded, distally referred sensations of touch and joint movement, and that the functionality of limb prostheses would be improved by a more natural control mechanism. We have recently demonstrated that it is possible to implant electrodes within individual fascicles of peripheral nerve stumps in amputees, that stimulation through these electrodes can produce graded, discrete sensations of touch or movement referred to the amputee's phantom hand, and that recordings of motor neuron activity associated with attempted movements of the phantom limb through these electrodes can be used as graded control signals. We report here that this approach allows amputees to both judge and set grip force and joint position in an artificial arm, in the absence of visual input, thus providing a substrate for better integration of the artificial limb into the amputee's body image. We believe this to be the first demonstration of direct neural feedback from and direct neural control of an artificial arm in amputees.

Integrity signals

Registry

Crossref · 10.1109/tnsre.2005.856072

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In amputees, the motor-sensory areas of the lost limb in the brain were activated when the subject grabbed an object with a prosthetic hand while looking at the action and feeling electrical stimulation.

    “A. Hernandez et al., in [3], explored the effect of electro-tactile feedback on amputees’ cerebral cortex using fMRI data, showing that the motor-sensory areas of the lost limb in a subject’s brain were activated when the subject grabbed an object with a prosthetic hand while looking at the action and feeling the electrical stimulation.”
  • USEA and LIFEs have been used successfully in short-term (less than a month) experiments in humans.

    “However, the USEA and LIFEs have been used successfully in short-term (less than a month) experiments in humans [7–9, 12, 14].”
  • Intensity has been manipulated by changing pulse amplitude, pulse width, or pulse frequency.

    “Intensity has been manipulated by changing pulse amplitude (Raspopovic et al., 2014), pulse width (Tan et al., 2014), or pulse frequency (Dhillon and Horch, 2005).”

    From Biomimetic approaches to bionic touch through a peripheral nerve interface (2015) · cites this paper as Dhillon and Horch, 2005

  • Stimulation of the nerve can also occasionally evoke proprioceptive sensations, for example sensations of movement of a finger or a joint or a specific hand configuration.

    “Stimulation of the nerve can also occasionally evoke proprioceptive sensations, for example sensations of movement of a finger or a joint or a specific hand configuration (Clark et al., 2014;Dhillon and Horch, 2005;Tan et al., 2015;2014), though the quality and gradedness of these sensations has not been systematically explored.”

    From Biomimetic approaches to bionic touch through a peripheral nerve interface (2015) · cites this paper as Dhillon and Horch, 2005

  • Within the stimulation intensity range, graded sensations of pressure are evoked and patients are generally able to distinguish a small number of distinct pressure levels reliably.

    “Within that range, graded sensations of pressure are evoked and patients are generally able to distinguish a small number of distinct pressure levels reliably (Dhillon and Horch, 2005;Raspopovic et al., 2014;Tan et al., 2014).”

    From Biomimetic approaches to bionic touch through a peripheral nerve interface (2015) · cites this paper as Dhillon and Horch, 2005

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Dhillon, G. S., & Horch, K. W.
Affiliations
  • Baylor College of Medicine (US)
  • University of Utah (US)
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2005-12
Volume
13
Issue
4
Pages
468-472
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2103386113
Cited by
573
References
36
Citations by year
2026: 8 · 2025: 13 · 2024: 20 · 2023: 17 · 2022: 26 · 2021: 29 · 2020: 33 · 2019: 45 · 2018: 45 · 2017: 31 · 2016: 38 · 2015: 34 · 2014: 40 · 2013: 31 · 2012: 37
FWCI
5.54
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
Keywords
neuroprosthetics, prosthetic arm, peripheral nerve stimulation, sensory feedback, phantom limb, grip force control, joint position control, motor neuron activity, amputees, body image, visual deprivation
MeSH terms
Amputees, Arm, Artificial Limbs, Electric Stimulation, Electrodes, Implanted, Feedback, Humans, Male, Motor Neurons, Peripheral Nerves, Prosthesis Design, Sensory Receptor Cells, Treatment Outcome, Equipment Failure Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review