An Analysis of the Accuracy of Wearable Sensors for Classifying the Causes of Falls in Humans
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Falls are the number one cause of injury in older adults. Wearable sensors, typically consisting of accelerometers and/or gyroscopes, represent a promising technology for preventing and mitigating the effects of falls. At present, the goal of such "ambulatory fall monitors" is to detect the occurrence of a fall and alert care providers to this event. Future systems may also provide information on the causes and circumstances of falls, to aid clinical diagnosis and targeting of interventions. As a first step towards this goal, the objective of the current study was to develop and evaluate the accuracy of a wearable sensor system for determining the causes of falls. Sixteen young adults participated in experimental trials involving falls due to slips, trips, and "other" causes of imbalance. Three-dimensional acceleration data acquired during the falling trials were input to a linear discriminant analysis technique. This routine achieved 96% sensitivity and 98% specificity in distinguishing the causes of a falls using acceleration data from three markers (left ankle, right ankle, and sternum). In contrast, a single marker provided 54% sensitivity and two markers provided 89% sensitivity. These results indicate the utility of a three-node accelerometer array for distinguishing the cause of falls.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Activity Recognition from User-Annotated Acceleration Data
Bao, L., & Intille, S. S. (2004) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-24646-6_1 · Cited by 3,147
Portable preimpact fall detector with inertial sensors
Wu, G., & Xue, S. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.916282 · Cited by 227
Cited by
Wearable Sensors for Human Activity Monitoring: A Review
Mukhopadhyay, S. C. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2370945 · Cited by 1,401
Machine learning in medical applications: a review of state-of-the-art methods
Shehab, M., Abualigah, L., Shambour, Q., Abu-Hashem, M. A., Shambour, M. K. Y., Alsalibi, A. I., & Gandomi, A. H. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.105458 · Cited by 542
Flexible Hybrid Sensors for Health Monitoring: Materials and Mechanisms to Render Wearability
Gao, Y., Yu, L., Yeo, J. C., & Lim, C. T. (2020) · Advanced Materials · doi:10.1002/adma.201902133 · Cited by 505
Detecting Falls with Wearable Sensors Using Machine Learning Techniques
Özdemir, A., & Barshan, B. (2014) · Sensors · doi:10.3390/s140610691 · Cited by 375
Automatic Fall Monitoring: A Review
Pannurat, N., Thiemjarus, S., & Nantajeewarawat, E. (2014) · Sensors · doi:10.3390/s140712900 · Cited by 237
“…F18, F21 TB Sen = 100% Spe = 94% Fang et al. (2012) [106] 1 3 F5, F19 TB, RB Sen = 72.22% Spe = 73.78% Kangas et al. (2012) [69] 6 8 F5, F15 TB, RB N/A Aziz and Robinovitch (2011) [105] 9 - F1, F3 LDA Acc = 97%–98% Bagnasco et al.(2011) [79] 4 9 F5 TB, RB Sen = 71%–88% Spe = 89%–100% Gjoreski et…”
BackgroundInfluential
Metadata
- Authors
- Aziz, O., & Robinovitch, S. N.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2011-12
- Volume
- 19
- Issue
- 6
- Pages
- 670-676
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2040879679
- Cited by
- 97
- References
- 2
- FWCI
- 6.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.