The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Dry and Noncontact EEG Sensors for Mobile Brain–Computer Interfaces
Abstract
Dry and noncontact electroencephalographic (EEG) electrodes, which do not require gel or even direct scalp coupling, have been considered as an enabler of practical, real-world, brain-computer interface (BCI) platforms. This study compares wet electrodes to dry and through hair, noncontact electrodes within a steady state visual evoked potential (SSVEP) BCI paradigm. The construction of a dry contact electrode, featuring fingered contact posts and active buffering circuitry is presented. Additionally, the development of a new, noncontact, capacitive electrode that utilizes a custom integrated, high-impedance analog front-end is introduced. Offline tests on 10 subjects characterize the signal quality from the different electrodes and demonstrate that acquisition of small amplitude, SSVEP signals is possible, even through hair using the new integrated noncontact sensor. Online BCI experiments demonstrate that the information transfer rate (ITR) with the dry electrodes is comparable to that of wet electrodes, completely without the need for gel or other conductive media. In addition, data from the noncontact electrode, operating on the top of hair, show a maximum ITR in excess of 19 bits/min at 100% accuracy (versus 29.2 bits/min for wet electrodes and 34.4 bits/min for dry electrodes), a level that has never been demonstrated before. The results of these experiments show that both dry and noncontact electrodes, with further development, may become a viable tool for both future mobile BCI and general EEG applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review
Chi, Y. M., Jung, T.-P., & Cauwenberghs, G. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084078 · Cited by 1,061
Self-citationBin, G., Gao, X., Yan, Z., Hong, B., & Gao, S. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046002 · Cited by 773
A practical VEP-based brain-computer interface
Wang, Y., Wang, R., Gao, X., Hong, B., & Gao, S. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875576 · Cited by 617
Self-citationBrain-Computer Interfaces Based on Visual Evoked Potentials
Wang, Y., Gao, X., Hong, B., Jia, C., & Gao, S. (2008) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2008.923958 · Cited by 423
Self-citationNovel Dry Polymer Foam Electrodes for Long-Term EEG Measurement
Lin, C.-T., Liao, L.-D., Liu, Y.-H., Wang, I.-J., Lin, B.-S., & Chang, J.-Y. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2102353 · Cited by 336
A Dry EEG-System for Scientific Research and Brain–Computer Interfaces
Zander, T. O., Lehne, M., Ihme, K. A., Jatzev, S., Correia, J., Kothe, C. A., Picht, B., & Nijboer, F. (2011) · Frontiers in Neuroscience · doi:10.3389/fnins.2011.00053 · Cited by 177
A dry electrode for EEG recording
Taheri, B. A., Knight, R. T., & Smith, R. L. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90053-1 · Cited by 176
A cell-phone-based brain–computer interface for communication in daily life
Wang, Y.-T., Wang, Y., & Jung, T.-P. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025018 · Cited by 173
Self-citationNoninvasive Neural Prostheses Using Mobile and Wireless EEG
Lin, C.-T., Ko, L.-W., Chiou, J.-C., Duann, J.-R., Huang, R.-S., Liang, S.-F., Chiu, T.-W., & Jung, T.-P. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922561 · Cited by 160
Self-citationCharacterization of micromachined spiked biopotential electrodes
Griss, P., Tolvanen-Laakso, H., Meriläinen, P., & Stemme, G. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.1001974 · Cited by 149
Brain-computer interface based on the high-frequency steady-state visual evoked potential
Yijun, W., Ruiping, W., Xiaorong, G., & Gao, S. (2005) · International Conference on Neural Interface and Control · doi:10.1109/icnic.2005.1499837 · Cited by 112
A mobile EEG system with dry electrodes
Gargiulo, G. D., Bifulco, P., Calvo, R. A., Cesarelli, M., Jin, C. T., & André, V. S. (2008) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2008.4696927 · Cited by 101
Chi, Y. M., & Cauwenberghs, G. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333527 · Cited by 92
Self-citationENOBIO dry electrophysiology electrode; first human trial plus wireless electrode system
Ruffini, G., Dunne, S., Farrés, E., Lozano, I., Watts, P. C. P., Silva, S. R. P., Grau, C., Fuentemilla, L., Marco‐Pallarés, J., & Vandecasteele, B. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353895 · Cited by 67
Validation of a Dry Electrode System for EEG
Estepp, J. R., Christensen, J. C., Monnin, J. W., Davis, I. M., & Wilson, G. F. (2009) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/154193120905301802 · Cited by 55
Extraction of SSVEP signals of a capacitive EEG helmet for Human Machine Interface
Oehler, M., Neumann, P., Becker, M., Curio, G., & Schilling, M. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650211 · Cited by 43
An active, microfabricated, scalp electrode array for EEG recording
Alizadeh-Taheri, B., Smith, R. L., & Knight, R. T. (1996) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(97)80023-4 · Cited by 36
Validation of a Dry Electrode System for EEG
Estepp, J. R., Christensen, J. C., Monnin, J. W., Davis, I. M., & Wilson, G. F. (2009) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1518/107118109x12524443346077 · Cited by 21
Hoffmann, U., Fimbel, E. J., & Keller, T. (2009) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2009.5109334 · Cited by 16
Integrated ultra-high impedance front-end for non-contact biopotential sensing
Yu, M., Maier, C., & Cauwenberghs, G. (2011) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2011.6107826 · Cited by 14
Self-citation
Cited by
Zheng, W.-L., & Lu, B.-L. (2015) · IEEE Transactions on Autonomous Mental Development · doi:10.1109/tamd.2015.2431497 · Cited by 2,595
EEG Emotion Recognition Using Dynamical Graph Convolutional Neural Networks
Song, T., Zheng, W., Song, P., & Cui, Z. (2020) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2018.2817622 · Cited by 1,597
Brain computer interface: control signals review
Ramadan, R. A., & Vasilakos, A. V. (2017) · Neurocomputing · doi:10.1016/j.neucom.2016.10.024 · Cited by 551
Brain–Computer Interfaces Using Sensorimotor Rhythms: Current State and Future Perspectives
Yuan, H., & He, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2312397 · Cited by 492
EEG-Based Spatio–Temporal Convolutional Neural Network for Driver Fatigue Evaluation
Gao, Z., Wang, X., Yang, Y., Mu, C., Cai, Q., Dang, W., & Zuo, S. (2019) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2018.2886414 · Cited by 482
Metadata
- Authors
- Chi, Y. M., Wang, Y.-T., Wang, Y., Maier, C., Jung, T.-P., & Cauwenberghs, G.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2012-03
- Volume
- 20
- Issue
- 2
- Pages
- 228-235
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2142239365
- Cited by
- 297
- References
- 21
- FWCI
- 9.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.