Powered Hip Exoskeletons Can Reduce the User's Hip and Ankle Muscle Activations During Walking
Open accessThe DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
In this paper, we study the human locomotor adaptation to the action of a powered exoskeleton providing assistive torque at the user's hip during walking. To this end, we propose a controller that provides the user's hip with a fraction of the nominal torque profile, adapted to the specific gait features of the user from Winter's reference data . The assistive controller has been implemented on the ALEX II exoskeleton and tested on ten healthy subjects. Experimental results show that when assisted by the exoskeleton, users can reduce the muscle effort compared to free walking. Despite providing assistance only to the hip joint, both hip and ankle muscles significantly reduced their activation, indicating a clear tradeoff between hip and ankle strategy to propel walking.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring Health: A Guide to Rating Scales and Questionnaires
McDowell, I., & Newell, C. (1987) · Cited by 4,207
Human balance and posture control during standing and walking
Winter, D. (1995) · Gait & Posture · doi:10.1016/0966-6362(96)82849-9 · Cited by 3,421
Emery, A. E. (2002) · The Lancet · doi:10.1016/s0140-6736(02)07815-7 · Cited by 1,667
Measuring Health: A Guide to Rating Scales and Questionnaires
Anderson, J. (1997) · The Journal of Nervous & Mental Disease · doi:10.1097/00005053-199711000-00018 · Cited by 1,527
The biomechanics and motor control of human gait : normal, elderly and pathological
Winter, D. A. (1991) · University of Waterloo Press eBooks · Cited by 1,428
Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327
Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., Van Asseldonk, E. H. F., & van der Kooij, H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903919 · Cited by 1,280
Neptune, R. R., Kautz, S. A., & Zajac, F. E. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00105-1 · Cited by 1,132
The biomechanics and motor control of human gait: Normal, elderly, and pathological
Brand, R. A. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90236-t · Cited by 1,103
The biomechanics and motor control of human gait
Winter, D. A. (1987) · University of Waterloo Press eBooks · Cited by 767
Cited by
State of the Art and Future Directions for Lower Limb Robotic Exoskeletons
Young, A. J., & Ferris, D. P. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2521160 · Cited by 901
Review of assistive strategies in powered lower-limb orthoses and exoskeletons
Yan, T., Cempini, M., Oddo, C. M., & Vitiello, N. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.09.032 · Cited by 715
A Review on Lower Limb Rehabilitation Exoskeleton Robots
Shi, D., Zhang, W., Zhang, W., & Ding, X. (2019) · Chinese Journal of Mechanical Engineering · doi:10.1186/s10033-019-0389-8 · Cited by 508
Review of control strategies for lower-limb exoskeletons to assist gait
Baud, R., Manzoori, A. R., Ijspeert, A., & Bouri, M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00906-3 · Cited by 381
Quintero, D., Villarreal, D. J., Lambert, D. J., Kapp, S., & Gregg, R. D. (2018) · IEEE Transactions on Robotics · doi:10.1109/tro.2018.2794536 · Cited by 252
“The hip exoskeletons in [37] and [38] use the hip angle to drive the dynamics of an artificial phase oscillator that determines when to inject or dissipate energy, which may not be sufficient to replicate joint kinematics in a prosthesis application.”
Effect of timing of hip extension assistance during loaded walking with a soft exosuit
Ding, Y., Panizzolo, F. A., Siviy, C., Malcolm, P., Galiana, I., Holt, K. G., & Walsh, C. J. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0196-8 · Cited by 249
“gated the effects of powering the hip joint via simulation [34–36] or experimental studies [4, 5, 21, 24, 37].”
Performance Evaluation of Lower Limb Exoskeletons: A Systematic Review
Pinto-Fernandez, D., Torricelli, D., Sanchez-Villamanan, M. D. C., Aller, F., Mombaur, K., Conti, R., Vitiello, N., Moreno, J. C., & Pons, J. L. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2989481 · Cited by 220
Biomechanical and Physiological Evaluation of Multi-Joint Assistance With Soft Exosuits
Ding, Y., Galiana, I., Asbeck, A. T., De Rossi, S. M. M., Bae, J., Santos, T. R. T., de Araujo, V. L., Lee, S., Holt, K. G., & Walsh, C. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2523250 · Cited by 217
“There have also been a few studies with various research platforms that have looked at the effects of applying torques at the hip on various biomechanical and physiological variables [16], [36]–[38].”
BackgroundDevelopment of Active Lower Limb Robotic-Based Orthosis and Exoskeleton Devices: A Systematic Review
Kalita, B., Narayan, J., & Dwivedy, S. K. (2021) · International Journal of Social Robotics · doi:10.1007/s12369-020-00662-9 · Cited by 203
A unified perspective on ankle push-off in human walking
Zelik, K. E., & Adamczyk, P. G. (2016) · Journal of Experimental Biology · doi:10.1242/jeb.140376 · Cited by 200
“There is empirical evidence in support of both of these contentions: increased ankle push-off reducing hip work (Caputo and Collins, 2014; Koller et al., 2015; Lewis and Ferris, 2008) and increased hip powering reducing ankle push-off (Lenzi et al., 2013).”
BackgroundLerner, Z. F., Damiano, D. L., & Bulea, T. C. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aam9145 · Cited by 187
Fully autonomous hip exoskeleton saves metabolic cost of walking
Seo, K., Lee, J., Lee, Y., Ha, T., & Shim, Y. (2016) · 2016 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2016.7487663 · Cited by 177
“The hip brace is fabricated using engineering plastic, and coated with carbon fiber, to be structurally flexible so it can fit tightly to the pelvis when its inner belt system is fastened.”
Simulating ideal assistive devices to reduce the metabolic cost of walking with heavy loads
Dembia, C. L., Silder, A., Uchida, T. K., Hicks, J. L., & Delp, S. L. (2017) · PLOS ONE · doi:10.1371/journal.pone.0180320 · Cited by 170
Simulating Ideal Assistive Devices to Reduce the Metabolic Cost of Running
Uchida, T. K., Seth, A., Pouya, S., Dembia, C. L., Hicks, J. L., & Delp, S. L. (2016) · PLOS ONE · doi:10.1371/journal.pone.0163417 · Cited by 164
Real-Time Gait Phase Estimation for Robotic Hip Exoskeleton Control During Multimodal Locomotion
Kang, I., Molinaro, D. D., Duggal, S., Chen, Y., Kunapuli, P., & Young, A. J. (2021) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2021.3062562 · Cited by 162
Kim, J., Quinlivan, B. T., Deprey, L.-A., Arumukhom Revi, D., Eckert-Erdheim, A., Murphy, P., Orzel, D., & Walsh, C. J. (2022) · Scientific Reports · doi:10.1038/s41598-022-14784-9 · Cited by 91
Molinaro, D. D., Kang, I., Camargo, J., Gombolay, M. C., & Young, A. J. (2022) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2022.3144025 · Cited by 90
Recognition of walking environments and gait period by surface electromyography
Kyeong, S., Shin, W., Yang, M., Heo, U., Feng, J.-R., & Kim, J. (2019) · Frontiers of Information Technology & Electronic Engineering · doi:10.1631/fitee.1800601 · Cited by 68
Metadata
- Authors
- Lenzi, T., Carrozza, M. C., & Agrawal, S. K.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2013-11
- Volume
- 21
- Issue
- 6
- Pages
- 938-948
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2094532097
- Cited by
- 215
- References
- 62
- FWCI
- 7.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.