The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Effect of timing of hip extension assistance during loaded walking with a soft exosuit
Open accessAbstract
BACKGROUND: Recent advances in wearable robotic devices have demonstrated the ability to reduce the metabolic cost of walking by assisting the ankle joint. To achieve greater gains in the future it will be important to determine optimal actuation parameters and explore the effect of assisting other joints. The aim of the present work is to investigate how the timing of hip extension assistance affects the positive mechanical power delivered by an exosuit and its effect on biological joint power and metabolic cost during loaded walking. In this study, we evaluated 4 different hip assistive profiles with different actuation timings: early-start-early-peak (ESEP), early-start-late-peak (ESLP), late-start-early-peak (LSEP), late-start-late-peak (LSLP). METHODS: while carrying a 23 kg backpack load. We tested five different conditions: four with the assistive profiles described above and one unpowered condition where no assistance was provided. We evaluated participants' lower limb kinetics, kinematics, metabolic cost and muscle activation. RESULTS: ) with respect to the other powered conditions. Biological joint power was significantly reduced at the hip (ESEP and ESLP) and at the knee (ESEP, ESLP and LSEP) with respect to the unpowered condition. Further, all assistive profiles significantly reduced the metabolic cost of walking compared to the unpowered condition by 5.7 ± 1.5 %, 8.5 ± 0.9 %, 6.3 ± 1.4 % and 7.1 ± 1.9 % (mean ± SE for ESEP, ESLP, LSEP, LSLP, respectively). CONCLUSIONS: The highest positive mechanical power delivered by the soft exosuit was reported in the ESLP condition, which showed also a significant reduction in both biological hip and knee joint power. Further, the ESLP condition had the highest average metabolic reduction among the powered conditions. Future work on autonomous hip exoskeletons may incorporate these considerations when designing effective control strategies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of recommendations for SEMG sensors and sensor placement procedures
Hermens, H. J., Freriks, B., Disselhorst-Klug, C., & Rau, G. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00027-4 · Cited by 7,213
Esquenazi, A., Talaty, M., Packel, A., & Saulino, M. (2012) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e318269d9a3 · Cited by 958
Robotic Orthosis Lokomat: a rehabilitation and research tool
Jezernik, S., Colombo, G., Keller, T., Frueh, H., & Morari, M. (2003) · Neuromodulation Technology at the Neural Interface · doi:10.1046/j.1525-1403.2003.03017.x · Cited by 503
A biologically inspired soft exosuit for walking assistance
Asbeck, A. T., De Rossi, S. M. M., Holt, K. G., & Walsh, C. J. (2015) · The International Journal of Robotics Research · doi:10.1177/0278364914562476 · Cited by 450
Self-citationA lightweight soft exosuit for gait assistance
Wehner, M., Quinlivan, B., Aubin, P. M., Martinez-Villalpando, E., Baumann, M., Stirling, L., Holt, K., Wood, R., & Walsh, C. (2013) · 2013 IEEE International Conference on Robotics and Automation · doi:10.1109/icra.2013.6631046 · Cited by 361
Self-citation
Cited by
Human-in-the-loop optimization of hip assistance with a soft exosuit during walking
Ding, Y., Kim, M., Kuindersma, S., & Walsh, C. J. (2018) · Science Robotics · doi:10.1126/scirobotics.aar5438 · Cited by 612
Self-citationReducing the metabolic rate of walking and running with a versatile, portable exosuit
Kim, J., Lee, G., Heimgartner, R., Arumukhom Revi, D., Karavas, N., Nathanson, D., Galiana, I., Eckert-Erdheim, A., Murphy, P., Perry, D., et al. (2019) · Science · doi:10.1126/science.aav7536 · Cited by 482
Self-citationThe exoskeleton expansion: improving walking and running economy
Sawicki, G. S., Beck, O. N., Kang, I., & Young, A. J. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00663-9 · Cited by 424
Review of control strategies for lower-limb exoskeletons to assist gait
Baud, R., Manzoori, A. R., Ijspeert, A., & Bouri, M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00906-3 · Cited by 381
Assistance magnitude versus metabolic cost reductions for a tethered multiarticular soft exosuit
Quinlivan, B. T., Lee, S., Malcolm, P., Rossi, D. M., Grimmer, M., Siviy, C., Karavas, N., Wagner, D., Asbeck, A., Galiana, I., et al. (2017) · Science Robotics · doi:10.1126/scirobotics.aah4416 · Cited by 370
Self-citation
Metadata
- Authors
- Ding, Y., Panizzolo, F. A., Siviy, C., Malcolm, P., Galiana, I., Holt, K. G., & Walsh, C. J.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2016-10-03
- Volume
- 13
- Issue
- 1
- Pages
- 87-87
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2528868074
- Cited by
- 249
- References
- 5
- FWCI
- 11.40
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of timing of hip extension assistance during loaded walking with a soft exosuit. https://app.cochat.ai/papers/10.1186/s12984-016-0196-8
- The paper
- Ding, Y., Panizzolo, F. A., Siviy, C., Malcolm, P., Galiana, I., Holt, K. G., & Walsh, C. J. (2016). Effect of timing of hip extension assistance during loaded walking with a soft exosuit. Journal of NeuroEngineering and Rehabilitation. https://doi.org/10.1186/s12984-016-0196-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.