The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
A Preliminary Assessment of Legged Mobility Provided by a Lower Limb Exoskeleton for Persons With Paraplegia
Open accessAbstract
This paper presents an assessment of a lower limb exoskeleton for providing legged mobility to people with paraplegia. In particular, the paper presents a single-subject case study comparing legged locomotion using the exoskeleton to locomotion using knee-ankle-foot orthoses (KAFOs) on a subject with a T10 motor and sensory complete injury. The assessment utilizes three assessment instruments to characterize legged mobility, which are the timed up-and-go test, the Ten-Meter Walk Test (10 MWT), and the Six-Minute Walk Test (6 MWT), which collectively assess the subject's ability to stand, walk, turn, and sit. The exertion associated with each assessment instrument was assessed using the Physiological Cost Index. Results indicate that the subject was able to perform the respective assessment instruments 25%, 70%, and 80% faster with the exoskeleton relative to the KAFOs for the timed up-and-go test, the 10 MWT, and the 6 MWT, respectively. Measurements of exertion indicate that the exoskeleton requires 1.6, 5.2, and 3.2 times less exertion than the KAFOs for each respective assessment instrument. The results indicate that the enhancement in speed and reduction in exertion are more significant during walking than during gait transitions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The Vanderbilt exoskeleton developed by Goldfarb et al [17], [35] is another LEE that enables paralyzed patients to perform basic motions such as walking, sitting, standing, and walking up and down stairs.”
From Recent developments and challenges of lower extremity exoskeletons (2016) · cites this paper as [35]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“With the help of the exoskeleton, the patient is able to stand up and sit down, walk, turn, and go up and down stairs.”
From Recent developments and challenges of lower extremity exoskeletons (2016) · cites this paper as [35]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This exoskeleton has been implemented in a patient with a T10 motor and sensory complete injury and the exoskeleton can provide a repeatable gait with knee and hip joint amplitudes that are similar to those observed during non-SCI walking [35].”
From Recent developments and challenges of lower extremity exoskeletons (2016) · cites this paper as [35]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Timed “Up & Go”: A Test of Basic Functional Mobility for Frail Elderly Persons
Podsiadlo, D., & Richardson, S. (1991) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1991.tb01616.x · Cited by 14,418
Predicting the Probability for Falls in Community-Dwelling Older Adults Using the Timed Up & Go Test
Shumway‐Cook, A., Brauer, S., & Woollacott, M. H. (2000) · Physical Therapy · doi:10.1093/ptj/80.9.896 · Cited by 3,355
Predicting the Probability for Falls in Community-Dwelling Older Adults
Shumway‐Cook, A., Baldwin, M., Polissar, N. L., & Gruber, W. C. (1997) · Physical Therapy · doi:10.1093/ptj/77.8.812 · Cited by 1,593
Esquenazi, A., Talaty, M., Packel, A., & Saulino, M. (2012) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e318269d9a3 · Cited by 958
Reliability of Measurements Obtained With the Timed “Up & Go” Test in People With Parkinson Disease
Morris, S., Morris, M. E., & Iansek, R. (2001) · Physical Therapy · doi:10.1093/ptj/81.2.810 · Cited by 664
Mobility-related function in older adults: Assessment with a 6-minute walk test
Harada, N. D., Chiu, V., & Stewart, A. L. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90236-8 · Cited by 548
Zeilig, G., Weingarden, H., Zwecker, M., Dudkiewicz, I., Bloch, A., & Esquenazi, A. (2012) · The Journal of Spinal Cord Medicine · doi:10.1179/2045772312y.0000000003 · Cited by 537
van Hedel, H. J. A., Wirz, M., & Dietz, V. (2005) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2004.02.010 · Cited by 484
Intention-based walking support for paraplegia patients with robot suit HAL
Suzuki, K., Mito, G., Kawamoto, H., Hasegawa, Y., & Sankai, Y. (2007) · Advanced Robotics · doi:10.1163/156855307781746061 · Cited by 474
Intention-Based Walking Support for Paraplegia Patients with Robot Suit HAL
Suzuki, K., Mito, G., Kawamoto, H., et al. (2010) · InTech eBooks · doi:10.5772/8835 · Cited by 401
Research works printed but not linked: 2
- 10.1682/JRRD.2008.07.0087 · DOI
- phillips, 1987, Spinal cord injury A guide for patient and family
Cited by
Sorted by citations
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
Recent developments and challenges of lower extremity exoskeletons
Chen, B., Ma, H., Qin, L.-Y., Gao, F., Chan, K.-M., Law, S.-W., Qin, L., & Liao, W.-H. (2016) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2015.09.007 · Cited by 501
“This exoskeleton has been implemented in a patient with a T10 motor and sensory complete injury and the exoskeleton can provide a repeatable gait with knee and hip joint Lower extremity exoskeletons amplitudes that are similar to those observed during non-SCI walking [35].”
Method
Metadata
- Authors
- Farris, R. J., Quintero, H. A., Murray, S. A., Ha, K. H., Hartigan, C., & Goldfarb, M.
- Affiliations
- Vanderbilt University (US)
- Shepherd Center (US)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2014-05
- Volume
- 22
- Issue
- 3
- Pages
- 482-490
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- PMC
- PMC4476394
- OpenAlex
- W2062363643
- Cited by
- 208
- References
- 49
- Citations by year
- 2026: 4 · 2025: 11 · 2024: 12 · 2023: 11 · 2022: 21 · 2021: 29 · 2020: 26 · 2019: 17 · 2018: 22 · 2017: 17 · 2016: 21 · 2015: 16 · 2014: 1
- FWCI
- 6.98
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- U.S. Department of Health and Human Services
- National Institutes of Health
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (R01HD059832)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- lower limb exoskeleton, paraplegia, knee-ankle-foot orthoses, complete spinal cord injury, walking speed, gait transition, Timed Up and Go test, 6-minute walk test, physiological cost index
- MeSH terms
- Adult, Artificial Limbs, Physical Exertion, Heart Rate, Humans, Male, Movement, Paraplegia, Prosthesis Design, Spinal Cord Injuries, Treatment Outcome, Lower Extremity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review