The DOI matches its Crossref record.
Extracting Signals Robust to Electrode Number and Shift for Online Simultaneous and Proportional Myoelectric Control by Factorization Algorithms
Abstract
Previous research proposed the extraction of myoelectric control signals by linear factorization of multi-channel electromyogram (EMG) recordings from forearm muscles. This paper further analyses the theoretical basis for dimensionality reduction in high-density EMG signals from forearm muscles. Moreover, it shows that the factorization of muscular activation patterns in weights and activation signals by non-negative matrix factorization (NMF) is robust with respect to the channel configuration from where the EMG signals are obtained. High-density surface EMG signals were recorded from the forearm muscles of six individuals. Weights and activation signals extracted offline from 10 channel configurations with varying channel numbers (6, 8, 16, 192 channels) were highly similar. Additionally, the method proved to be robust against electrode shifts in both transversal and longitudinal direction with respect to the muscle fibers. In a second experiment, six subjects directly used the activation signals extracted from high-density EMG for online goal-directed control tasks involving simultaneous and proportional control of two degrees-of-freedom of the wrist. The synergy weights for this control task were extracted from a reference configuration and activation signals were calculated online from the reference configuration as well as from the two shifted configurations, simulating electrode shift. Despite the electrode shift, the task completion rate, task completion time, and execution efficiency were generally not statistically different among electrode configurations. Online performances were also mostly similar when using either 6, 8, or 16 EMG channels. The robustness of the method to the number and location of channels, proved both offline and online, indicates that EMG signals recorded from forearm muscles can be approximated as linear instantaneous mixtures of activation signals and justifies the use of linear factorization algorithms for extracting, in a minimally supervised way, control signals for simultaneous multi-degree of freedom prosthesis control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Self-citationBi, L., Feleke, A. >., & Guan, C. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.02.011 · Cited by 418
Myoelectric control of prosthetic hands: state-of-the-art review
Geethanjali, P. (2016) · Medical Devices: Evidence and Research · doi:10.2147/mder.s91102 · Cited by 342
Prosthetic Myoelectric Control Strategies: A Clinical Perspective
Roche, A. D., Rehbaum, H., Farina, D., & Aszmann, O. C. (2014) · Current Surgery Reports · doi:10.1007/s40137-013-0044-8 · Cited by 261
Self-citationThe neural mechanisms of manual dexterity
Sobinov, A. R., & Bensmaia, S. J. (2021) · Nature Reviews Neuroscience · doi:10.1038/s41583-021-00528-7 · Cited by 248
Metadata
- Authors
- Muceli, S., Jiang, N., & Farina, D.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2014-05
- Volume
- 22
- Issue
- 3
- Pages
- 623-633
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2021320602
- Cited by
- 172
- References
- 0
- FWCI
- 6.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Extracting Signals Robust to Electrode Number and Shift for Online Simultaneous and Proportional Myoelectric Control by Factorization Algorithms. https://app.cochat.ai/papers/10.1109/tnsre.2013.2282898
- The paper
- Muceli, S., Jiang, N., & Farina, D. (2014). Extracting Signals Robust to Electrode Number and Shift for Online Simultaneous and Proportional Myoelectric Control by Factorization Algorithms. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2013.2282898
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.