Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 52 of the 60 references it cites were found in a registry or an index.

Quantifying the Deep Tendon Reflex Using Varying Tendon Indentation Depths: Applications to Spasticity

Chardon, Matthieu K., Rymer, W. Zev, Suresh, Nina L. · 2014 · IEEE Transactions on Neural Systems and Rehabilitation Engineering

Abstract

The deep tendon reflex (DTR) is often utilized to characterize the neuromuscular health of individuals because it is cheap, quick to implement, and requires limited equipment. However, DTR assessment is unreliable and assessor-dependent improve the reliability of the DTR assessment, we devised a novel standardization procedure. Our approach is based on the hypothesis that the neuromuscular state of a muscle changes systematically with respect to the indentation depth of its tendon. We tested the hypothesis by progressively indenting the biceps tendons on each side of nine hemiplegic stroke survivors to different depths, and then superimposing a series of brief controlled taps at each indentation depth to elicit a reflex response. Our results show that there exists a unique indentation depth at which reflex responses are consistently recorded (termed the Reflex Threshold) with increasing amplitude along increasing indentation depth. We further show that the reflex threshold depth is systematically smaller on the affected side of stroke survivors and that it is negatively correlated with the Modified Ashworth Score (VAF 70%). Our procedure also enables measurement of passive mechanical properties at the indentation location. In conclusion, our study shows that controlling for the indentation depth of the tendon of a muscle alters its reflex response predictably. Our novel device and method could be used to estimate neuromuscular changes in muscle (e.g., spasticity). Although some refinement is needed, this method opens the door to more reliable quantification of the DTR.

Overview

Integrity signals

Registry

Crossref · 10.1109/tnsre.2014.2299753

Cites

52 of 52 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 60 references

Research works printed but not linked: 13

  1. 1957, Hand reflex gun
  2. 1956, Machine for Testing Reflex Actions of Humans
  3. 1996, Apparatus for achilles tendon reflex testing
  4. 1955, Apparatus for testing and measuring human reflexes
  5. 1999, Method for testing reflexes using electrocardiograph
  6. 1954, Machine for Testing Reflex Actions of Humans
  7. 2010, Reflexometry and hormone function
  8. 1996, Reflex measuring device and method
  9. 1973, Reflex meter
  10. 1995, Quantitative neural percussion hammer
  11. 0, Reflex Hammer
  12. 2008, System and method for evaluating neuromuscular and joint properties
  13. lance, 1980, Symp Synopsis, 485

Cited by

See all 17

Metadata

Authors
Chardon, M. K., Rymer, W. Z., & Suresh, N. L.
Affiliations
  • Northwestern University (US)
  • Shirley Ryan AbilityLab (US)
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2014-03
Volume
22
Issue
2
Pages
280-289
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2098614977
Cited by
17
References
60
Citations by year
2026: 1 · 2025: 2 · 2023: 1 · 2021: 2 · 2020: 1 · 2019: 3 · 2018: 1 · 2017: 1 · 2016: 1 · 2015: 3 · 2014: 1
FWCI
1.30
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institute of Neurological Disorders and Stroke
  • Eunice Kennedy Shriver National Institute of Child Health and Human Development (R24HD050821)
Topics
  • Health Sciences › Medicine › Clinical Neurology › Botulinum Toxin and Related Neurological Disorders
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
Keywords
deep tendon reflexes, reflex threshold, spasticity, stroke, hemiplegia, biceps tendon, neuromuscular assessment, Modified Ashworth Scale, passive mechanical properties, assessment standardization
MeSH terms
Aged, Data Interpretation, Statistical, Electromyography, Female, Humans, Functional Laterality, Male, Middle Aged, Muscle Spasticity, Neurologic Examination, Physical Stimulation, Reflex, Stretch, Tendons, Survivors, Muscle, Skeletal, Stroke

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantifying the Deep Tendon Reflex Using Varying Tendon Indentation Depths: Applications to Spasticity. https://app.cochat.ai/papers/10.1109/tnsre.2014.2299753
The paper
Chardon, M. K., Rymer, W. Z., & Suresh, N. L. (2014). Quantifying the Deep Tendon Reflex Using Varying Tendon Indentation Depths: Applications to Spasticity. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2014.2299753

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.