Movement Error Rate for Evaluation of Machine Learning Methods for sEMG-Based Hand Movement Classification
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
There has been increasing interest in applying learning algorithms to improve the dexterity of myoelectric prostheses. In this work, we present a large-scale benchmark evaluation on the second iteration of the publicly released NinaPro database, which contains surface electromyography data for 6 DOF force activations as well as for 40 discrete hand movements. The evaluation involves a modern kernel method and compares performance of three feature representations and three kernel functions. Both the force regression and movement classification problems can be learned successfully when using a nonlinear kernel function, while the exp- χ(2) kernel outperforms the more popular radial basis function kernel in all cases. Furthermore, combining surface electromyography and accelerometry in a multimodal classifier results in significant increases in accuracy as compared to when either modality is used individually. Since window-based classification accuracy should not be considered in isolation to estimate prosthetic controllability, we also provide results in terms of classification mistakes and prediction delay. To this extent, we propose the movement error rate as an alternative to the standard window-based accuracy. This error rate is insensitive to prediction delays and it allows us therefore to quantify mistakes and delays as independent performance characteristics. This type of analysis confirms that the inclusion of accelerometry is superior, as it results in fewer mistakes while at the same time reducing prediction delay.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to Support Vector Machines and Other Kernel-based Learning Methods
Cristianini, N., & Shawe-Taylor, J. (2000) · doi:10.1017/cbo9780511801389 · Cited by 13,855
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743 · cited 1×
“A total of 40 intact subjects participated in the data acquisition, consisting of 28 men and 12 women, 34 right-handed and 6 left-handed subjects.”
BackgroundControl of upper limb prostheses: terminology and proportional myoelectric control-a review
Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2196711 · Cited by 495 · cited 1×
“M ACHINE learning is increasingly being employed in the research setting to improve myoelectric control of prostheses (see [1], [2] and references therein).”
BackgroundEMG feature evaluation for movement control of upper extremity prostheses
Zardoshti-Kermani, M., Wheeler, B. C., Badie, K., & Hashemi, R. M. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481972 · Cited by 477 · cited 1×
“The increment of the sliding window was set to 10 ms (20 samples).”
BackgroundQuantifying Pattern Recognition—Based Myoelectric Control of Multifunctional Transradial Prostheses
Li, G., Schultz, A. E., & Kuiken, T. A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039619 · Cited by 443 · cited 1×
“[34], who in their experiments found this time to be around 200 ms in amputated as well as intact arms.”
Background
Cited by
Electromyography data for non-invasive naturally-controlled robotic hand prostheses
Atzori, M., Gijsberts, A., Castellini, C., Caputo, B., Hager, A.-G. M., Elsig, S., Giatsidis, G., Bassetto, F., & Müller, H. (2014) · Scientific Data · doi:10.1038/sdata.2014.53 · Cited by 969
Self-citationAtzori, M., Cognolato, M., & Müller, H. (2016) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2016.00009 · Cited by 684
“Five signal features and three classification methods were considered, according to previous application to the Ninapro sEMG database and to sEMG in general (Englehart and Hudgins, 2003; Kuzborskij et al., 2012; Atzori et al., 2014b; Gijsberts et al., 2014).”
BackgroundMethodComparison of six electromyography acquisition setups on hand movement classification tasks
Pizzolato, S., Tagliapietra, L., Cognolato, M., Reggiani, M., Müller, H., & Atzori, M. (2017) · PLOS ONE · doi:10.1371/journal.pone.0186132 · Cited by 421
Self-citation
Metadata
- Authors
- Gijsberts, A., Atzori, M., Castellini, C., Muller, H., & Caputo, B.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2014-07
- Volume
- 22
- Issue
- 4
- Pages
- 735-744
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2129566274
- Cited by
- 199
- References
- 5
- FWCI
- 5.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.