Closed-Loop Control of Grasping With a Myoelectric Hand Prosthesis: Which Are the Relevant Feedback Variables for Force Control?
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
In closed-loop control of grasping by hand prostheses, the feedback information sent to the user is usually the actual controlled variable, i.e., the grasp force. Although this choice is intuitive and logical, the force production is only the last step in the process of grasping. Therefore, this study evaluated the performance in controlling grasp strength using a hand prosthesis operated through a complete grasping sequence while varying the feedback variables (e.g., closing velocity, grasping force), which were provided to the user visually or through vibrotactile stimulation. The experiments were conducted on 13 volunteers who controlled the Otto Bock Sensor Hand Speed prosthesis. Results showed that vibrotactile patterns were able to replace the visual feedback. Interestingly, the experiments demonstrated that direct force feedback was not essential for the control of grasping force. The subjects were indeed able to control the grip strength, predictively, by estimating the grasping force from the prosthesis velocity of closing. Therefore, grasping without explicit force feedback is not completely blind, contrary to what is usually assumed. In our study we analyzed grasping with a specific prosthetic device, but the outcomes are also applicable for other devices, with one or more degrees-of-freedom. The necessary condition is that the electromyography (EMG) signal directly and proportionally controls the velocity/grasp force of the hand, which is a common approach among EMG controlled prosthetic devices. The results provide important indications on the design of closed-loop EMG controlled prosthetic systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Electrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827
Closed-loop control in prosthetic systems: Historical perspective
Childress, D. S. (1980) · Annals of Biomedical Engineering · doi:10.1007/bf02363433 · Cited by 158
Design and Evaluation of a Low-Cost Force Feedback System for Myoelectric Prosthetic Hands
Pylatiuk, C., Kargov, A., & Schulz, S. (2006) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-200604000-00007 · Cited by 156 · cited 1×
“[10] also applied a miniature vibration motor.”
Patterson, P. E., & Katz, J. A. (1992) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.1992.01.0001 · Cited by 147 · cited 1×
“Patterson and Katz [11] used a force matching task in subjects operating a myoelectrically controlled gripper to compare several feedback modalities: vibrations (motors) and pressure (pressure cuff), with and without vision.”
Method
Cited by
Emerging Wearable Interfaces and Algorithms for Hand Gesture Recognition: A Survey
Jiang, S., Kang, P., Song, X., Lo, B., & Shull, P. (2022) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3078190 · Cited by 270
Restoration of sensory information via bionic hands
Bensmaia, S. J., Tyler, D. J., & Micera, S. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00630-8 · Cited by 257
Schiefer, M., Tan, D., Sidek, S. M., & Tyler, D. J. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/1/016001 · Cited by 255
“Other studies have found vibrotactile feedback improves control over gripping force [12, 42] and detection of state transitions, such as the transition from not touching an object to touching an object [43].”
BackgroundA Review of Non-Invasive Sensory Feedback Methods for Transradial Prosthetic Hands
Stephens-Fripp, B., Alici, G., & Mutlu, R. (2018) · IEEE Access · doi:10.1109/access.2018.2791583 · Cited by 210
“Vibration has typically been used to communicate grasping force, however, a few studies have examined its role in communicating proprioceptive information [42], [50], [83], and some hybrid systems have”
BackgroundMultichannel electrotactile feedback for simultaneous and proportional myoelectric control
Patel, G. K., Dosen, S., Castellini, C., & Farina, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/5/056015 · Cited by 58
Self-citation
Metadata
- Authors
- Ninu, A., Dosen, S., Muceli, S., Rattay, F., Dietl, H., & Farina, D.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2014-09
- Volume
- 22
- Issue
- 5
- Pages
- 1041-1052
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2332378204
- Cited by
- 116
- References
- 5
- FWCI
- 4.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Closed-Loop Control of Grasping With a Myoelectric Hand Prosthesis: Which Are the Relevant Feedback Variables for Force Control? https://app.cochat.ai/papers/10.1109/tnsre.2014.2318431
- The paper
- Ninu, A., Dosen, S., Muceli, S., Rattay, F., Dietl, H., & Farina, D. (2014). Closed-Loop Control of Grasping With a Myoelectric Hand Prosthesis: Which Are the Relevant Feedback Variables for Force Control? IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2014.2318431
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.