The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Support Vector Regression for Improved Real-Time, Simultaneous Myoelectric Control
Abstract
This study describes the first application of a support vector machine (SVM) based scheme for real-time simultaneous and proportional myoelectric control of multiple degrees of freedom (DOFs). Three DOFs including wrist flexion-extension, abduction-adduction and forearm pronation-supination were investigated with 10 able-bodied subjects and two individuals with transradial limb deficiency (LD). A Fitts' law test involving real-time target acquisition tasks was conducted to compare the usability of the SVM-based control system to that of an artificial neural network (ANN) based method. Performance was assessed using the Fitts' law throughput value as well as additional metrics including completion rate, path efficiency and overshoot. The SVM-based approach outperformed the ANN-based system in every performance measure for able-bodied subjects. The SVM outperformed the ANN in path efficiency and throughput with the first LD subject and in throughput with the second LD subject. The superior performance of the SVM-based system appears to be due to its higher estimation accuracy of all DOFs during inactive and low amplitude segments (these periods were frequent during real-time control). Another advantage of the SVM-based method was that it substantially reduced the processing time for both training and real time control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cortes, C., & Vapnik, V. (1995) · Machine Learning · doi:10.1007/bf00994018 · Cited by 59,421
The information capacity of the human motor system in controlling the amplitude of movement.
Fitts, P. M. (1954) · Journal of Experimental Psychology · doi:10.1037/h0055392 · Cited by 6,466
Online Myoelectric Control of a Dexterous Hand Prosthesis by Transradial Amputees
Cipriani, C., Antfolk, C., Controzzi, M., Lundborg, G., Rosen, B., Carrozza, M. C., & Sebelius, F. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2108667 · Cited by 233
Cited by
Zhai, X., Jelfs, B., Chan, R. H. M., & Tin, C. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00379 · Cited by 357
Vu, P. P., Vaskov, A. K., Irwin, Z. T., Henning, P. T., Lueders, D. R., Laidlaw, A. T., Davis, A. J., Nu, C. S., Gates, D. H., Gillespie, R. B., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aay2857 · Cited by 291
Jaramillo-Yánez, A., Benalcázar, M. E., & Mena-Maldonado, E. (2020) · Sensors · doi:10.3390/s20092467 · Cited by 259
Vu, P. P., Irwin, Z. T., Bullard, A. J., Ambani, S. W., Sando, I. C., Urbanchek, M. G., Cederna, P. S., & Chestek, C. A. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2772961 · Cited by 61
Bio-signal based elbow angle and torque simultaneous prediction during isokinetic contraction
Zhou, Y., Liu, J., Zeng, J., Li, K., & Liu, H. (2019) · Science China Technological Sciences · doi:10.1007/s11431-018-9354-5 · Cited by 30
Metadata
- Authors
- Ameri, A., Kamavuako, E. N., Scheme, E. J., Englehart, K. B., & Parker, P. A.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2014-11
- Volume
- 22
- Issue
- 6
- Pages
- 1198-1209
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2155893840
- Cited by
- 171
- References
- 3
- FWCI
- 6.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Support Vector Regression for Improved Real-Time, Simultaneous Myoelectric Control. https://app.cochat.ai/papers/10.1109/tnsre.2014.2323576
- The paper
- Ameri, A., Kamavuako, E. N., Scheme, E. J., Englehart, K. B., & Parker, P. A. (2014). Support Vector Regression for Improved Real-Time, Simultaneous Myoelectric Control. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2014.2323576
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.