CoChat

The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.

Closed-Loop Continuous Hand Control via Chronic Recording of Regenerative Peripheral Nerve Interfaces

Vu, Philip P., Irwin, Zachary T., Bullard, Autumn J., Ambani, Shoshana W., Sando, Ian C., Urbanchek, Melanie G., Cederna, Paul S., Chestek, Cynthia A. · 2018 · IEEE Transactions on Neural Systems and Rehabilitation Engineering

Abstract

Loss of the upper limb imposes a devastating interruption to everyday life. Full restoration of natural arm control requires the ability to simultaneously control multiple degrees of freedom of the prosthetic arm and maintain that control over an extended period of time. Current clinically available myoelectric prostheses do not provide simultaneous control or consistency for transradial amputees. To address this issue, we have implemented a standard Kalman filter for continuous hand control using intramuscular electromyography (EMG) from both regenerative peripheral nerve interfaces (RPNI) and an intact muscle within non-human primates. Seven RPNIs and one intact muscle were implanted with indwelling bipolar intramuscular electrodes in two rhesus macaques. Following recuperations, function-specific EMG signals were recorded and then fed through the Kalman filter during a hand-movement behavioral task to continuously predict the monkey's finger position. We were able to reconstruct continuous finger movement offline with an average correlation of and a root mean squared error (RMSE) of 0.12 between actual and predicted position from two macaques. This finger movement prediction was also performed in real time to enable closed-loop neural control of a virtual hand. Compared with physical hand control, neural control performance was slightly slower but maintained an average target hit success rate of 96.70%. Recalibration longevity measurements maintained consistent average correlation over time but had a significant change in RMSE ( ). Additionally, extracted single units varied in amplitude by a factor of +18.65% and -25.85% compared with its mean. This is the first demonstration of chronic indwelling electrodes being used for continuous position control via the Kalman filter. Combining these analyses with our novel peripheral nerve interface, we believe that this demonstrates an important step in providing patients with more naturalistic control of their prosthetic limbs.

Overview

Integrity signals

Registry

Crossref · 10.1109/tnsre.2017.2772961

Cites

56 of 56 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 56 references

Cited by

See all 67

Metadata

Authors
Vu, P. P., Irwin, Z. T., Bullard, A. J., Ambani, S. W., Sando, I. C., Urbanchek, M. G., Cederna, P. S., & Chestek, C. A.
Affiliations
University of Michigan (US)
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2018-02
Volume
26
Issue
2
Pages
515-526
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2770125713
Cited by
61
References
56
Citations by year
2026: 4 · 2025: 5 · 2024: 6 · 2023: 4 · 2022: 10 · 2021: 10 · 2020: 11 · 2019: 10 · 2018: 1
FWCI
2.94
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Wallace H. Coulter Foundation
  • Plastic Surgery Foundation
  • Frederick A. Coller Surgical Society
  • NSF Graduate Research Fellowships
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
Keywords
regenerative peripheral nerve interface, Kalman filter, intramuscular electromyography, transradial amputation, upper limb prosthesis, rhesus monkeys, single-unit activity, recalibration, non-human primates
MeSH terms
Algorithms, Animals, Artificial Limbs, Calibration, Electric Stimulation, Electromyography, Fingers, Macaca mulatta, Peripheral Nerves, Prosthesis Design, Psychomotor Performance, User-Computer Interface, Upper Extremity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Closed-Loop Continuous Hand Control via Chronic Recording of Regenerative Peripheral Nerve Interfaces. https://app.cochat.ai/papers/10.1109/tnsre.2017.2772961
The paper
Vu, P. P., Irwin, Z. T., Bullard, A. J., Ambani, S. W., Sando, I. C., Urbanchek, M. G., Cederna, P. S., & Chestek, C. A. (2018). Closed-Loop Continuous Hand Control via Chronic Recording of Regenerative Peripheral Nerve Interfaces. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2017.2772961

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.