Design and Control of the MINDWALKER Exoskeleton
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Powered exoskeletons can empower paraplegics to stand and walk. Actively controlled hip ab/adduction (HAA) is needed for weight shift and for lateral foot placement to support dynamic balance control and to counteract disturbances in the frontal plane. Here, we describe the design, control, and preliminary evaluation of a novel exoskeleton, MINDWALKER. Besides powered hip flexion/extension and knee flexion/extension, it also has powered HAA. Each of the powered joints has a series elastic actuator, which can deliver 100 Nm torque and 1 kW power. A finite-state machine based controller provides gait assistance in both the sagittal and frontal planes. State transitions, such as stepping, can be triggered by the displacement of the Center of Mass (CoM). A novel step-width adaptation algorithm was proposed to stabilize lateral balance. We tested this exoskeleton on both healthy subjects and paraplegics. Experimental results showed that all users could successfully trigger steps by CoM displacement. The step-width adaptation algorithm could actively counteract disturbances, such as pushes. With the current implementations, stable walking without crutches has been achieved for healthy subjects but not yet for SCI paraplegics. More research and development is needed to improve the gait stability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robust Locally Weighted Regression and Smoothing Scatterplots
Cleveland, W. S. (1979) · Journal of the American Statistical Association · doi:10.1080/01621459.1979.10481038 · Cited by 11,594
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Biomechanics and Motor Control of Human Movement
Winter, D. A. (2009) · Wiley eBooks · doi:10.1002/9780470549148 · Cited by 6,066
McGeer, T. (1990) · The International Journal of Robotics Research · doi:10.1177/027836499000900206 · Cited by 3,359
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 1×
“, using brain or muscle activities, have been used for operating a human-augmentation exoskeleton [39] and manipulating an upper limb prosthesis [40], while they have not been applied in SCI gait assistance.”
MethodThe condition for dynamic stability
Hof, A. L., Gazendam, M. G. J., & Sinke, W. E. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.03.025 · Cited by 1,688
Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX)
Zoss, A. B., Kazerooni, H., & Chu, A. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.871087 · Cited by 1,170 · cited 1×
“However, rapid developments have only been achieved in recent years, resulting in several wearable exoskeletons [8]–[19].”
BackgroundCapture Point: A Step toward Humanoid Push Recovery
Pratt, J., Carff, J., Drakunov, S., & Goswami, A. (2006) · 2006 6th IEEE-RAS International Conference on Humanoid Robots · doi:10.1109/ichr.2006.321385 · Cited by 1,118
Wyndaele, M., & Wyndaele, J.-J. (2006) · Spinal Cord · doi:10.1038/sj.sc.3101893 · Cited by 1,116
Adaptive control of mechanical impedance by coactivation of antagonist muscles
Hogan, N. (1984) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1984.1103644 · Cited by 1,041
Active control of lateral balance in human walking
Bauby, C. E., & Kuo, A. D. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00101-9 · Cited by 851
Stabilization of Lateral Motion in Passive Dynamic Walking
Kuo, A. D. (1999) · The International Journal of Robotics Research · doi:10.1177/02783649922066655 · Cited by 650
The Effects of Adding Mass to the Legs on the Energetics and Biomechanics of Walking
BROWNING, R. C., MODICA, J. R., KRAM, R., & GOSWAMI, A. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31802b3562 · Cited by 603
The ‘extrapolated center of mass’ concept suggests a simple control of balance in walking
Hof, A. L. (2008) · Human Movement Science · doi:10.1016/j.humov.2007.08.003 · Cited by 596
Control of lateral balance in walking
Hof, A. L., van Bockel, R. M., Schoppen, T., & Postema, K. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2006.04.013 · Cited by 491
Mechanical and metabolic requirements for active lateral stabilization in human walking
Donelan, J. M., Shipman, D. W., Kram, R., & Kuo, A. D. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.06.002 · Cited by 490
Design and control of an exoskeleton for the elderly and patients
Kong, K., & Jeon, D. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.878550 · Cited by 403
Preliminary Evaluation of a Powered Lower Limb Orthosis to Aid Walking in Paraplegic Individuals
Farris, R. J., Quintero, H. A., & Goldfarb, M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2163083 · Cited by 342
Utilization of health services following spinal cord injury: a 6-year follow-up study
Dryden, D. M., Saunders, L. D., Rowe, B. H., May, L. A., Yiannakoulias, N., Svenson, L. W., Schopflocher, D. P., & Voaklander, D. C. (2004) · Spinal Cord · doi:10.1038/sj.sc.3101629 · Cited by 280
Hak, L., Houdijk, H., Beek, P. J., & van Dieën, J. H. (2013) · PLoS ONE · doi:10.1371/journal.pone.0082842 · Cited by 251
Functional priorities, assistive technology, and brain-computer interfaces after spinal cord injury
Collinger, J. L., Boninger, M. L., Bruns, T. M., Curley, K., Wang, W., & Weber, D. J. (2013) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2011.11.0213 · Cited by 248
Design and evaluation of Mina: A robotic orthosis for paraplegics
Neuhaus, P. D., Noorden, J. H., Craig, T. J., Torres, T., Kirschbaum, J., & Pratt, J. E. (2011) · 2011 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975468 · Cited by 208
Development of the IHMC Mobility Assist Exoskeleton
Kwa, H. K., Noorden, J., Missel, M., Craig, T., Pratt, J. E., & Neuhaus, P. D. (2009) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2009.5152394 · Cited by 169
EMG patterns during assisted walking in the exoskeleton
Labini, F. S., Scaleia, V. L., d’Avella, A., Pisotta, I., Tamburella, F., Scivoletto, G., Molinari, M., Wang, S., Wang, L., van Asseldonk, E. H. F., et al. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00423 · Cited by 157
Self-citationDesign of an electric series elastic actuated joint for robotic gait rehabilitation training
Lagoda, C., Schouten, A. C., Stienen, A. H. A., Hekman, E. E. G., & van der Kooij, H. (2010) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2010.5626010 · Cited by 138
Design of a Rotational Hydroelastic Actuator for a Powered Exoskeleton for Upper Limb Rehabilitation
Stienen, A. H. A., Hekman, E. E. G., ter Braak, H., Aalsma, A. M. M., van der Helm, F. C. T., & van der Kooij, H. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2018628 · Cited by 128
Estimation of Quasi-Stiffness of the Human Hip in the Stance Phase of Walking
Shamaei, K., Sawicki, G. S., & Dollar, A. M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0081841 · Cited by 118
Estimation of Quasi-Stiffness of the Human Knee in the Stance Phase of Walking
Shamaei, K., Sawicki, G. S., & Dollar, A. M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0059993 · Cited by 103
Control and implementation of a powered lower limb orthosis to aid walking in paraplegic individuals
Quintero, H. A., Farris, R. J., & Goldfarb, M. (2011) · 2011 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975481 · Cited by 88
Responses of human hip abductor muscles to lateral balance perturbations during walking
Hof, A. L., & Duysens, J. (2013) · Experimental Brain Research · doi:10.1007/s00221-013-3655-5 · Cited by 77
Massucci, M., Brunetti, G., Piperno, R., Betti, L., & Franceschini, M. (1998) · Spinal Cord · doi:10.1038/sj.sc.3100564 · Cited by 71
Control and Trajectory Generation of a Wearable Mobility Exoskeleton for Spinal Cord Injury Patients
Swift, T. A. (2011) · eScholarship (California Digital Library) · Cited by 30
Cited by
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Review of control strategies for lower-limb exoskeletons to assist gait
Baud, R., Manzoori, A. R., Ijspeert, A., & Bouri, M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00906-3 · Cited by 381
Opportunities and challenges in the development of exoskeletons for locomotor assistance
Siviy, C., Baker, L. M., Quinlivan, B. T., Porciuncula, F., Swaminathan, K., Awad, L. N., & Walsh, C. J. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00984-1 · Cited by 258
Metadata
- Authors
- Wang, S., Wang, L., Meijneke, C., van Asseldonk, E., Hoellinger, T., Cheron, G., Ivanenko, Y., La Scaleia, V., Sylos-Labini, F., Molinari, M., Tamburella, F., Pisotta, I., Thorsteinsson, F., Ilzkovitz, M., Gancet, J., Nevatia, Y., Hauffe, R., Zanow, F., & van der Kooij, H.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2015-03
- Volume
- 23
- Issue
- 2
- Pages
- 277-286
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2102159351
- Cited by
- 380
- References
- 32
- FWCI
- 10.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.