Improving the Robustness of Myoelectric Pattern Recognition for Upper Limb Prostheses by Covariate Shift Adaptation
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Fundamental changes over time of surface EMG signal characteristics are a challenge for myocontrol algorithms controlling prosthetic devices. These changes are generally caused by electrode shifts after donning and doffing, sweating, additional weight or varying arm positions, which results in a change of the signal distribution-a scenario often referred to as covariate shift. A substantial decrease in classification accuracy due to these factors hinders the possibility to directly translate EMG signals into accurate myoelectric control patterns outside laboratory conditions. To overcome this limitation, we propose the use of supervised adaptation methods. The approach is based on adapting a trained classifier using a small calibration set only, which incorporates the relevant aspects of the nonstationarities, but requires only less than 1 min of data recording. The method was tested first through an offline analysis on signals acquired across 5 days from seven able-bodied individuals and four amputees. Moreover, we also conducted a three day online experiment on eight able-bodied individuals and one amputee, assessing user performance and user-ratings of the controllability. Across different testing days, both offline and online performance improved significantly when shrinking the training model parameters by a given estimator towards the calibration set parameters. In the offline data analysis, the classification accuracy remained above 92% over five days with the proposed approach, whereas it decreased to 75% without adaptation. Similarly, in the online study, with the proposed approach the performance increased by 25% compared to a test without adaptation. These results indicate that the proposed methodology can contribute to improve robustness of myoelectric pattern recognition methods in daily life applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Elements of Statistical Learning
Hastie, T., Tibshirani, R., & Friedman, J. (2009) · Springer Series in Statistics · doi:10.1007/978-0-387-84858-7 · Cited by 25,970
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 2×
“In order to provide a direct comparison between our approach and the generally accepted state-of-the art feature set [4], the Hudgin feature set [3], we further investigated the influence of the feature choice and found an average improvement of 25% for LDA and of 11% for LDACMA when using logvar instead of the Hudgin…”
MethodA robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743 · cited 1×
“In order to provide a direct comparison between our approach and the generally accepted state-of-the art feature set [4], the Hudgin feature set [3], we further investigated”
ResultCovariate Shift Adaptation by Importance Weighted Cross Validation
Sugiyama, M., Krauledat, M., & Müller, K. (2007) · Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft) · doi:10.5555/1314498.1390324 · Cited by 1,233
Single-trial analysis and classification of ERP components — A tutorial
Blankertz, B., Lemm, S., Treder, M., Haufe, S., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.048 · Cited by 1,138 · cited 1×
“We propose an adaptation by shrinking the training parameters towards the ones obtained from the calibration set [20]:”
MethodSelf-citationTargeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089 · cited 1×
“Note that in this study we use an error measure that relies on completion time, which is distinct from alternative measures that use completion rate [21].”
MethodScheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969 · cited 2×
“[1], a full calibration was performed every day, which is very”
BackgroundHuang, Y., Englehart, K. B., Hudgins, B., & Chan, A. D. C. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856295 · Cited by 643 · cited 1×
“The main difference in performance between able-bodied and amputee users was a lower classification accuracy for the amputees, which is also reported in [15], [22], [23] and emphasized in Fig.”
Introduction to machine learning for brain imaging
Lemm, S., Blankertz, B., Dickhaus, T., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.11.004 · Cited by 630
Direct importance estimation for covariate shift adaptation
Sugiyama, M., Suzuki, T., Nakajima, S., Kashima, H., von Bünau, P., & Kawanabe, M. (2008) · Annals of the Institute of Statistical Mathematics · doi:10.1007/s10463-008-0197-x · Cited by 426 · cited 1×
“tation [11], [12] has been applied for binary classification prob-”
Method
Cited by
Deep Learning for EMG-based Human-Machine Interaction: A Review
Xiong, D., Zhang, D., Zhao, X., & Zhao, Y. (2021) · IEEE/CAA Journal of Automatica Sinica · doi:10.1109/jas.2021.1003865 · Cited by 395
Zhai, X., Jelfs, B., Chan, R. H. M., & Tin, C. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00379 · Cited by 357
Parajuli, N., Sreenivasan, N., Bifulco, P., Cesarelli, M., Savino, S., Niola, V., Esposito, D., Hamilton, T. J., Naik, G. R., Gunawardana, U., et al. (2019) · Sensors · doi:10.3390/s19204596 · Cited by 332
Emerging Wearable Interfaces and Algorithms for Hand Gesture Recognition: A Survey
Jiang, S., Kang, P., Song, X., Lo, B., & Shull, P. (2022) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3078190 · Cited by 270
Hahne, J. M., Schweisfurth, M. A., Koppe, M., & Farina, D. (2018) · Science Robotics · doi:10.1126/scirobotics.aat3630 · Cited by 216
Self-citationLi, W., Shi, P., & Yu, H. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.621885 · Cited by 211
“Intact subjects performed real movements of the hand, while amputees could only attempt imaginary movements without visual and sensory feedback, so that when they perform the same movements at a specific arm position, the residual muscles of amputated arm might produce sEMG patterns different from those of intact arm…”
BackgroundResnik, L., Huang, H. (., Winslow, A., Crouch, D. L., Zhang, F., & Wolk, N. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0361-3 · Cited by 174
Ameri, A., Akhaee, M. A., Scheme, E., & Englehart, K. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2962189 · Cited by 171
“Moreover, domain adaptation of LDA and QDA classifiers introduced in previous studies [12], [13], [24] were investigated, and the proposed CNN TL”
Influential
Metadata
- Authors
- Vidovic, M. M.-C., Hwang, H.-J., Amsuss, S., Hahne, J. M., Farina, D., & Muller, K.-R.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2016-09
- Volume
- 24
- Issue
- 9
- Pages
- 961-970
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2418845879
- Cited by
- 171
- References
- 23
- FWCI
- 4.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.