Cited by 15Hearing Loss and RehabilitationEEG and Brain-Computer InterfacesHearing, Cochlea, Tinnitus, Genetics

Template subtraction to remove CI stimulation artifacts in auditory steady-state responses in CI subjects.

Open access
Deprez, Hanne, Gransier, Robin, Hofmann, Michael, van Wieringen, Astrid, Wouters, Jan, Moonen, Marc·2017·IEEE Transactions on Neural Systems and Rehabilitation Engineering

Abstract

Cochlear implant (CI) stimulation artifacts are currently removed from electrically evoked steady-state response (EASSR) measurements based on a linear interpolation (LI) over the artifact-contaminated signal parts. LI is only successful if CI stimulation artifacts are shorter than the interpulse interval, i.e., for contralateral channels and stimulation pulse rates up to 500 pulses per second (pps). The objective of this paper is to develop and evaluate a template subtraction (TS) method to remove continuous CI stimulation artifacts in order to accurately measure EASSRs. The template construction (TC) is based on an EEG recording containing CI stimulation artifacts but no synchronous neural response. The constructed templates are subtracted from the recording of interest. Response amplitudes and latencies are compared for the TS and LI method, and for different TC durations. The response amplitudes and latencies in contralateral channels are the same after TS and LI, as expected. In ipsilateral channels, response amplitudes and latencies are within the expected range only after TS. The TC duration can be reduced from 5 min to 1 min without a significant effect on response latency. TS with a TC duration of only 1 min allows to remove all CI stimulation artifacts in individual contra- and ipsilateral EEG recording channels.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tnsre.2016.2622979

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The artifact waveform template can be obtained by least-mean-square algorithms, genetic algorithms, principal component analysis, and wavelet algorithms.

    “The template of the artifact waveform can be obtained by the least-mean-square algorithms, genetic algorithms (Qiu et al., 2015), principal component analysis (Deprez et al., 2017), and wavelet algorithms (Yochum and Binczak, 2015).”

    From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Deprez et al., 2017

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 2

  1. T. Zwolan, P. R. Kileny, C. Ashbaugh, and S. A. Telian, "Patient performance with the Cochlear Corporation '20+2' implant: bipolar vs monopolar activation," American Journal of Otolaryngology, vol. 17, no. 1996, pp. 717-723, 1996.
  2. T. W. Picton, M. S. John, A. Dimitrijevic, and D. Purcell, "Human auditory steady-state responses." International journal of audiology, vol. 42, no. 2012, pp. 177-219, 2003.

Cited by

Sorted by citations

Authors
Deprez, H., Gransier, R., Hofmann, M., van Wieringen, A., Wouters, J., & Moonen, M.
Affiliations
KU Leuven (BE)
Corresponding author
Deprez, Hanne
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2017-08
Volume
25
Issue
8
Pages
1322-1331
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2545789585
Cited by
15
References
32
Citations by year
2025: 2 · 2024: 1 · 2023: 1 · 2022: 2 · 2021: 4 · 2020: 1 · 2019: 2 · 2018: 1 · 2017: 1
FWCI
0.85
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
  • PubMed (publishedVersion)
  • Lirias (submittedVersion, other-oa)
Funders
  • Hermes Fund (141243)
  • IWT (150432)
  • FWO (G.066213)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Hearing Loss and Rehabilitation
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
  • Life Sciences › Neuroscience › Sensory Systems › Hearing, Cochlea, Tinnitus, Genetics
Keywords
template subtraction, artifact removal, linear interpolation, response latency, response amplitude
MeSH terms
Algorithms, Cochlear Implants, Electroencephalography, Evoked Potentials, Auditory, Hearing Loss, Sensorineural, Humans, Sensitivity and Specificity, Signal Processing, Computer-Assisted, Reproducibility of Results, Artifacts

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review