A Real-Time Gait Event Detection for Lower Limb Prosthesis Control and Evaluation
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Lower extremity amputees suffer from mobility limitations which will result in a degradation of their quality of life. Wearable sensors are frequently used to assess spatio-temporal, kinematic and kinetic parameters providing the means to establish an interactive control of the amputee-prosthesis-environment system. Gait events and the gait phase detection of an amputee's locomotion are vital for controlling lower limb prosthetic devices. The paper presents an approach to real-time gait event detection for lower limb amputees using a wireless gyroscope attached to the shank when performing level ground and ramp activities. The results were validated using both healthy and amputee subjects and showed that the time differences in identifying Initial Contact (IC) and Toe Off (TO) events were larger in a transfemoral amputee when compared to the control subjects and a transtibial amputee (TTA). Overall, the time difference latency lies within a range of ±50 ms while the detection rate was 100% for all activities. Based on the validated results, the IC and TO events can be accurately detected using the proposed system in both control subjects and amputees when performing activities of daily living and can also be utilized in the clinical setup for rehabilitation and assessing the performance of lower limb prosthesis users.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A practical gait analysis system using gyroscopes
Tong, K., & Granat, M. H. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00030-2 · Cited by 460 · cited 2×
“They can be placed anywhere along the same plane on the same segment to produce identical signals [21].”
BackgroundVariation in the recorded incidence of amputation of the lower limb in England
Holman, N., Young, R. J., & Jeffcoate, W. J. (2012) · Diabetologia · doi:10.1007/s00125-012-2468-6 · Cited by 226 · cited 1×
“2636367 109 lower limb amputations were carried out in 151 hospitals during 2007–2010 period [2].”
Background
Cited by
Internet of Things for Smart Healthcare: Technologies, Challenges, and Opportunities
Baker, S. B., Xiang, W., & Atkinson, I. (2017) · IEEE Access · doi:10.1109/access.2017.2775180 · Cited by 1,130
Wearable sensor-based real-time gait detection: A systematic review
Prasanth, H., Caban, M., Keller, U., Courtine, G., Ijspeert, A., Vallery, H., & von Zitzewitz, J. (2021) · Sensors · doi:10.3390/s21082727 · Cited by 348
Wang, Y., Cheng, X., Jabban, L., Sui, X., & Zhang, D. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3167686 · Cited by 70
IMU-Based Monitoring for Assistive Diagnosis and Management of IoHT: A Review
Bo, F., Yerebakan, M., Dai, Y., Wang, W., Li, J., Hu, B., & Gao, S. (2022) · Healthcare · doi:10.3390/healthcare10071210 · Cited by 35
Whole body awareness for controlling a robotic transfemoral prosthesis
Parri, A., Martini, E., Geeroms, J., Flynn, L., Pasquini, G., Crea, S., Molino Lova, R., Lefeber, D., Kamnik, R., Munih, M., et al. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00025 · Cited by 29
Metadata
- Authors
- Maqbool, H. F., Husman, M. A. B., Awad, M. I., Abouhossein, A., Iqbal, N., & Dehghani-Sanij, A. A.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2017-09
- Volume
- 25
- Issue
- 9
- Pages
- 1500-1509
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2559852960
- Cited by
- 138
- References
- 2
- FWCI
- 4.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Real-Time Gait Event Detection for Lower Limb Prosthesis Control and Evaluation. https://app.cochat.ai/papers/10.1109/tnsre.2016.2636367
- The paper
- Maqbool, H. F., Husman, M. A. B., Awad, M. I., Abouhossein, A., Iqbal, N., & Dehghani-Sanij, A. A. (2017). A Real-Time Gait Event Detection for Lower Limb Prosthesis Control and Evaluation. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2016.2636367
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.