A CNN-Based Method for Intent Recognition Using Inertial Measurement Units and Intelligent Lower Limb Prosthesis
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Powered intelligent lower limb prosthesis can actuate the knee and ankle joints, allowing transfemoral amputees to perform seamless transitions between locomotion states with the help of an intent recognition system. However, prior intent recognition studies often installed multiple sensors on the prosthesis, and they employed machine learning techniques to analyze time-series data with empirical features. We alternatively propose a novel method for training an intent recognition system that provides natural transitions between level walk, stair ascent / descent, and ramp ascent / descent. Since the transition between two neighboring states is driven by motion intent, we aim to explore the mapping between the motion state of a healthy leg and an amputee's motion intent before the upcoming transition of the prosthesis. We use inertial measurement units (IMUs) and put them on the healthy leg of lower limb amputees for monitoring its locomotion state. We analyze IMU data within the early swing phase of the healthy leg, and feed data into a convolutional neural network (CNN) to learn the feature mapping without expert participation. The proposed method can predict the motion intent of both unilateral amputees and the able-bodied, and help to adaptively calibrate the control strategy for actuating powered intelligent prosthesis in advance. The experimental results show that the recognition accuracy can reach a high level (94.15% for the able-bodied, 89.23% for amputees) on 13 classes of motion intent, containing five steady states on different terrains as well as eight transitional states among the steady states.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
3D Convolutional Neural Networks for Human Action Recognition
Ji, S., Xu, W., Yang, M., & Yu, K. (2013) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2012.59 · Cited by 6,235
Identifying Medical Diagnoses and Treatable Diseases by Image-Based Deep Learning
Kermany, D. S., Goldbaum, M., Cai, W., Valentim, C. C. S., Liang, H., Baxter, S. L., McKeown, A., Yang, G., Wu, X., Yan, F., et al. (2018) · Cell · doi:10.1016/j.cell.2018.02.010 · Cited by 4,842
Human activity recognition with smartphone sensors using deep learning neural networks
Ronao, C. A., & Cho, S.-B. (2016) · Expert Systems with Applications · doi:10.1016/j.eswa.2016.04.032 · Cited by 1,215
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047 · cited 2×
“Then, the lowlevel controller eventually actuates the prosthesis based on the control strategy [4].”
BackgroundMethodHuman Activity Recognition Using Wearable Sensors by Deep Convolutional Neural Networks
Jiang, W., & Yin, Z. (2015) · Proceedings of the 23rd ACM international conference on Multimedia · doi:10.1145/2733373.2806333 · Cited by 676 · cited 1×
“, human activity recognition (HAR) [32], especially HAR based on wearable sensors [33]–[35].”
BackgroundHuang, H., Zhang, F., Hargrove, L. J., Dou, Z., Rogers, D. R., & Englehart, K. B. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2161671 · Cited by 542 · cited 1×
“They also used a combination of sEMG and load cell information from five transfemoral amputees [11].”
Method
Cited by
ViT-LLMR: Vision Transformer-based lower limb motion recognition from fusion signals of MMG and IMU
Zhang, H., Yang, K., Cao, G., & Xia, C. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.104508 · Cited by 28
Sheng, M., Wang, W.-J., Tong, T.-T., Yang, Y.-Y., Chen, H.-L., & Su, B.-Y. (2021) · Computational Intelligence and Neuroscience · doi:10.1155/2021/5631730 · Cited by 7
Self-citation
Metadata
- Authors
- Su, B.-Y., Wang, J., Liu, S.-Q., Sheng, M., Jiang, J., & Xiang, K.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2019-05
- Volume
- 27
- Issue
- 5
- Pages
- 1032-1042
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2944662892
- Cited by
- 176
- References
- 9
- FWCI
- 5.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A CNN-Based Method for Intent Recognition Using Inertial Measurement Units and Intelligent Lower Limb Prosthesis. https://app.cochat.ai/papers/10.1109/tnsre.2019.2909585
- The paper
- Su, B.-Y., Wang, J., Liu, S.-Q., Sheng, M., Jiang, J., & Xiang, K. (2019). A CNN-Based Method for Intent Recognition Using Inertial Measurement Units and Intelligent Lower Limb Prosthesis. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2019.2909585
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.